• 제목/요약/키워드: Mold Temperature

검색결과 1,161건 처리시간 0.045초

다수 캐비티 사출금형에서 성형 인자가 충전 불균형에 미치는 영향 (Effects of processing Factors on Filling Imbalances in Multi-cavity Injection Mold.)

  • 강철민;정영득
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 추계학술대회논문집
    • /
    • pp.54-57
    • /
    • 2004
  • Almost all injection molds have multi-cavity runner for mass production, which are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalances have sometimes been observed. These filling imbalances have historically been considered as result of uneven mold temperature and mold deflection, but it actually results from non-symmetrically shear, pressure, temperature distribution within melt material as it flows through the runner system. Filling imbalance could be decreased by modifying processing conditions that are related to shear, pressure, temperature such as injection rate, mold temperature, injection pressure, melt temperature. In this study, a series of experiment was conducted using Taguchi method to determine which processing condition influence as the primary cause of filling imbalance in geometrically balanced runner system. As a result of experiments, this paper could present an optimal processing condition to minimize variable that brings about filling imbalance geometrically balanced runner system

  • PDF

성형조건과 수지의 종류에 따른 사출 성형품의 성형 수축 (Shrinkage in Injection molded Part for Operational Conditions and Resins)

  • 모정혁;김현진;류민영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.363-370
    • /
    • 2003
  • Shrinkage of injection molded parts is different form operational conditions of injection molding such as injection temperature, injection pressure and mold temperature, and mold design such as gate size. It is also various for different resins which have crystalline structure or not. In this study part shrinkage was investigated for various operational condition and resins; PBT for crystalline polymer, and PC and PMMA for amorphous polymer was used in experiment. Crystalline polymer shows higher part shrinkage by about three times than amorphous polymer. Part shrinkage increased as injection temperature and mold temperature increased and injection pressure decreased. Part shrinkage decreased as gate size increased since the pressure delivery is mush easier for large gate size. Part shrinkage according to the gate location was that the position in the part with close to the gate showed large shrinkage and this phenomenon might be occurred by residual stress.

  • PDF

주상용 몰드변압기의 온도분포 해석과 온도상승 시험 (The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer)

  • 조한구;이운용;김석수;이종득
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.780-782
    • /
    • 2001
  • The mold transformer has anti-burnt and possibility of small size contrary to oil-immersed transformer. The mold transformer has generally cooling duct between low voltage coil and high voltage coil and also made by one body molding for small size and low loss. In this paper, the temperature distribution of designed 50kVA pole mold transformer for power distribution is investigated by FEM program. The designed transformer is also manufactured and temperature rise test is carried out.

  • PDF

플라스틱의 사출성형조건이 응력완화에 미치는 영향 (The Effect of the Injection Molding Conditions of Plastics on the Stress Relaxation)

  • 정석주;황봉갑
    • 한국안전학회지
    • /
    • 제13권1호
    • /
    • pp.19-25
    • /
    • 1998
  • In this study, proper injection molding condition has been studied through stress relaxation tests in order to experimentally investigate the effect of the condition on softening of mold product, using specimens produced under the different conditions according to the recommendation of resin manufactures. As a result, softening of the specimens was found to be strongly influenced by material melting temperature. The specimen with higher material melting temperature is found to have lower softening. However, softening of the specimen with lower mold temperature has an decrement, compared with other specimens. In particular, specimen with notch is influenced by mold temperature. The softening increase with higher injection speed and pressure. Finally in order to improve softening, material melting temperature, injection speed and injection pressure were found to be increased with low mold temperature.

  • PDF

주상용 몰드 변압기의 온도분포 해석과 온도상승 시험 (The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer)

  • 조한구;김석수;이운용;이종득
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.245-247
    • /
    • 2001
  • In this paper, the temperature distribution and thermal stress analysis of 50kVA pole mold transformer for power distribution are investigated by FEM program. The temperature rise test of designed mold transformer is carried out and test result is analyzed compare to simulation data.

  • PDF

순수 티타늄 주조체의 주형온도에 따른 용탕반응성 및 표면거칠기 (Metal-Mold Reaction and Surface Roughness Measurement of Pure Titanium Casting Specimens with Mold Temperatures)

  • 차성수;송영주;박수철
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.297-305
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the change of metal-mold reaction and surface roughness in titanium casting specimens for phosphate-silica alumina bonded investment with mold temperatures. Methods: The metal-phosphate silica alumina bonded mold interface reaction and surface roughness of titanium casting specimens according to mold temperatures were investigated. The Specimens were analysed by scanning electron microscopy and surface roughness tester. Results: The oxidation behavior indicated by the growth of oxide thickness. The titanium-oxide layer were consisted two layer of a porous external and a dense internal one. The reaction layer and surface roughness increased with increasing investment material temperature. Conclusion: In this work, The most suitable mold temperature in casting of pure titanium was $200^{\circ}C$.

사출성형품의 웰드라인 강도에 관한 연구 (A Study on the Weld Line Strength in Injection Molded Part)

  • 모정혁;홍형식;류민영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.211-216
    • /
    • 2003
  • Weld line in injection molded part is one of the defect in injection molding process. Weld line deteriorates not only appearance quality but mechanical property. In this study weld line strength has been examined according to the injection operational conditions, materials and mold designs. PC and PP were used, and four different specimens were used in this experiment. Weld line strength decreased as injection temperature increases for PC. It was more dependent on mold temperature than injection temperature for PP Among the four different specimens, uneven thickness specimen showed the highest weld line strength.

  • PDF

내압력.온도센서를 갖는 표준 인장시편용 사출금형설계 및 성형 (Design of Injection Mold with Cavity Pressure/Temperature Sensors and Molding for Standard Tensile Test Specimen)

  • 이도명;한병기;이옥성;이성희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1416-1419
    • /
    • 2005
  • Design and manufacturing of plastic injection mold with cavity pressure/temperature sensors were performed in the present study for tensile test specimen. Standards of mold-base and tensile test specimen were used to design an injection molding system. Cavity pressure and temperature sensors were placed on the side of fixed platen of injection mold machine to prevent them from external impact damage. Injection molding experiments with variations of injection speed and melt temperature were performed and polycarbonate tensile specimens were prepared for the tensile test. It was shown that injection molding processing parameters can have effect on the mechanical properties of the plastic injection molded part.

  • PDF

과공정 Al-Si합금의 원심주조시 용탕온도와 금형회전수가 경사기능 조직에 미치는 영향에 대한 해석적 고찰 (A Numerical Study of the Effect of Casting Temperature and Rotational Frequency of Mold on the Functionally Graded Microstructure in Centrifugal Casting of Hyper-eutectic Al-Si Alloy)

  • 박정욱;김헌주
    • 한국주조공학회지
    • /
    • 제29권2호
    • /
    • pp.78-85
    • /
    • 2009
  • Functionally graded microstructure of centrifugal cast Al-Si alloy, especially distribution of primary Si particles according to the changes of melt pouring temperature and rotation frequency was investigated by numerical simulation. Moving velocity of Si particles increased as the melt pouring temperature and rotational frequency of mold increased. Therefore, segregation tendency of primary Si particles toward inner side of cylindrical sample increased as the melt pouring temperature and rotational frequency of mold increased. Rich distribution region of particles was located at 0.9, 0.7, 0.4 mm from inner surface of cylindrical sample under the centrifugal cast condition of $750^{\circ}C$ melt pouring temperature and 1500, 2000 and 2500 rpm mold rotational frequencies, respectively, by numerical simulation.