• Title/Summary/Keyword: Moisture-in-Oil

Search Result 375, Processing Time 0.029 seconds

Influence of Moisture Content and Seed Dimensions on Mechanical Oil Expression from African Oil Bean (Pentaclethra macrophylla Benth) Seed

  • Aremu, Ademola K.;Ogunlade, Clement A.
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.193-200
    • /
    • 2016
  • Purpose: New low-cost oilseeds are needed to meet an ever-increasing demand for oil for food, pharmaceutical, and industrial applications. African oil bean seed is a tropical crop that is underutilized and has high oil yields, but there have been no studies conducted on its mechanical oil expression up to now. The objective of this work was to investigate the effect of moisture content and seed dimensions on mechanical oil expression from the seeds. Methods: Fresh oil bean seeds were procured, de-hulled, and cleaned. Initial seed moisture content, obtained in accordance with the ASAE standard, was 12% dry basis (db). The seeds were further conditioned by dehydration and rehydration prior to oil expression to obtain four other moisture levels of 8, 10, 14, and 16% db. The major diameter of the seeds was measured using digital vernier calipers, and the seeds were classified into size dimensions (< 40, 41-45, 46-50, 51-55, and > 55 mm). The oil yield and expression efficiency were obtained in accordance with standard evaluation methods. Results: The highest oil yield and expression efficiency (47.74% and 78.96%, respectively) were obtained for a moisture content of 8% db and seed dimensions of < 40 mm, while the lowest oil yield and expression efficiency (41.35% and 68.28%, respectively) were obtained for a moisture content of 14% db and seed dimensions between 51-55 mm. A mathematical model was developed to predict oil yield for known moisture content and seed dimensions, with a coefficient of determination $R^2$ of 95% and the confidence level of the predictive model of 84.17%. The probability of prediction F ratio showed that moisture content influence was more significant than seed dimensions. Conclusions: The higher the moisture content and larger the seed dimensions, the lower the oil yield from African oil bean seeds.

Electrification Tendency of Oil Adding Moisture and Dust (수분 및 머지의 첨가에 따른 절연유의 대전경향)

  • 김두석;권동진;강창구
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.5
    • /
    • pp.50-56
    • /
    • 1992
  • This paper presents the effect of moisture and dust on streaming electrification in transformer oil, in order to investigate the electrification tendency of oil adding moisture an dust. Authors designed series electrification device to analyse streaming electrification phenomena easily. Experimental results show that the streaming current is linearly increased with oil velocity and it has a peak value at about a 50 [%]. Adding of moisture and dust in oil decreased charging level and it was dominant in case of moisture.

  • PDF

Electrification tendency of oil adding dust (먼지의 첨가에 따른 절편유의 대전경향)

  • 곽희로;김두석;권동진;조국희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.60-63
    • /
    • 1992
  • This paper presents the effect of moisture and dust on streaming electrification in transformer oil, in order to investigate the electrification tendency of oil adding moisture and dost. Authors designed series electrification device to analyse streaming electrification phenomena easily. Experimental results show that adding of moisture and dust in oil decreased charging level and it was dominant in case of moisture.

  • PDF

A Study on the Changes in the Oil and Moisture Condition of Facial Skin in Women in their 20s and 30s (20-30대 여성의 안면 피부 유·수분 상태 변화 연구)

  • Choi, Ji-woo;Lee, Yoo-jeong;Shin, Sae-young
    • Journal of Fashion Business
    • /
    • v.25 no.4
    • /
    • pp.1-13
    • /
    • 2021
  • As interest in skin care increases, this study aims to contribute to the development of the beauty self-care market by providing basic data through the measurement of the oil and moisture skin condition of women in their 20s and 30s. The study was conducted from November 27, 2020 to January 31, 2021, with 20 women in their 20s and 30s divided into 4 groups, A~D, by age, 5 per group. Skin measurements were taken four times at 4 hour intervals at 0H, 4H, 8H, and 12H based on the first measurement that was taken within 30 minutes after waking up, and the oil and moisture indices were observed over time. As a result, both T and U zones showed significant differences in moisture levels over time, with no difference between groups for both T and U zones. Moisture decreased the most between 0H to 4H, and moisture changed the least between 4H to 8H. Changes in moisture increased the similar at 0H and 12H. The oil condition changed more irregularly compared to moisture over time, but all groups showed lower oil content in the U-zone compared to the T-zone. Overall, the facial oil and moisture conditions of women in their 20s and 30s changed over time, indicating that the skin changes in real time. The fact that the skin data, which was measured in the primary activity living environment, can be used as basic research data in the beauty self-care market is meaningful.

Embedded System-Based Fast Fourier Transform Method for Measuring Water Content in Crude Oil

  • Shuqi Jia;Xiaolei Wang;Zhe Kan
    • Journal of Information Processing Systems
    • /
    • v.20 no.3
    • /
    • pp.399-408
    • /
    • 2024
  • The moisture content of crude oil notably affects various aspects of oil production, storage, transportation, and exploration. However, accurately measuring this moisture content is challenging because of numerous influencing factors, leading to a lack of precision in existing detection methods. This inadequacy hinders the progress of China's petroleum industry. To overcome these challenges, this paper proposes a conductivity-based method for measuring crude oil moisture content. By employing an embedded system, we designed a sensor comprising five electrodes. Additionally, we developed signal excitation and signal processing circuits. Moreover, a software program was designed to analyze and compute the output signal using fast Fourier transform operations. This facilitated the identification of flow patterns, computation of relevant flow rates, and establishment of correlation rates based on frequency spectral characteristics. Based on experimental results, we established a functional relationship between measurement parameters and crude oil moisture content. This study enhanced the precision of moisture content measurement, thereby addressing existing limitations and fostering the advancement of China's petroleum industry.

Analysis on Monopole Antenna for Moisture Determination in Oil Palm Fruit Using Finite Difference Method

  • Cheng, E.M.;Abbas, Z.;Rahim @ Samsuddin, H.A.;Lee, K.Y.;You, K.Y.;Hassan, J.;Zainuddin, H.;Khor, S.F.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1754-1762
    • /
    • 2016
  • Finite difference analysis were applied to study the principle operation of monopole antenna for moisture determination in oil palm fruit at 2 GHz. The electromagnetic field interact with oil palm fruit on the interface between the antenna and oil palm fruit and cause a reflection. The reflection measurement is based on mismatch impedance or dielectric properties between two media. Reflection coefficient is used to quantify the level of reflection. The monopole antenna was made of RG405/U semi-rigid coaxial cable with an inner and outer diameter of 0.45 mm and 1.50 mm, respectively with 2.23 mm length of protruding conductor over 5.66 cm length of monopole antenna. This monopole antenna for moisture detection was compared with induced EMF method in terms of reflection coefficient at 2 GHz. The results show that the complex reflection coefficient measured using monopole antenna provides significant results to predict moisture content in oil palm fruit.

Diagnosis for the Transformer depend on Moisture and Furfural Detecting in Oil (절열유중의 수분 및 Furfural 검출을 이용한 유입변압기 상태진단)

  • Choi Gwang-beom;Eo Soo-young;Kweon Dong-jin;Lee Dong-joon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.546-552
    • /
    • 2005
  • In this paper, a present condition with gas-in-oil diagnosis which used to condition analysis for oil insulated transformer is investigated and reason why hydrogen used to basic diagnosis for the transformer is described. This paper gives an overview of background knowledge that should to consider as moisture detecting of oil immersed paper and how could we approach to life expectancy of oil insulated transformer through detecting furfural compound.

Development of an Integrated Oil Purification System (통합형 오일 정제 시스템의 개발)

  • Hong, Sung-Ho;Lee, Kyung-Hee;Jeong, Nam-Wha
    • Tribology and Lubricants
    • /
    • v.38 no.4
    • /
    • pp.121-127
    • /
    • 2022
  • This study presents the development of an integrated oil purification system consisting of moisture removal, oil flushing, and oil filtering devices. In this system, the oil flushing device is combined with a micro-bubble generator. Oil purification is necessary for ensuring the high performance of the lubricant through the efficient removal of contaminants and thus enables good maintenance of mechanical systems. The developed purification system removes moisture, varnish, and solid particles. Moreover, during oil purification, the oil flushing device separates foreign materials and contaminants remaining in the lubricating oil piping or mechanical systems. The microbubble generator, which is combined with the oil flushing device, can separate harmful contaminants, such as sludge, wear particles, and rust, from piping or lubrication systems through the cavitation effect. Moisture is removed using a double high-vacuum chamber, while sludge and varnish are removed via electro-absorption using a high-voltage generator. Additionally, the total maintenance cost of the system is reduced through the use of domestically fabricated cartridge filters composed of glass fiber and cellulose. The heater, which maintains the temperature of the lubricant at 60℃, can process 41,000 L of lubricant simultaneously. Multiple tests confirmed that the proposed integrated purification system exhibits good performance in oil flushing and removal of water and varnish.

Application of Dielectric Spectroscopy Measurements for Estimating Moisture Content in Power Transformers

  • Ekanayake, Chandima;Gubanski, Stanislaw M.;Fernando, M.A.R.M.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.81-89
    • /
    • 2004
  • Frequency Domain Spectroscopy (FDS) measurements were performed on pressboard samples containing different moisture contents and on insulation system of power transformers. The results were used for evaluating sensitivity of the so-called X - Y model, which is applied for estimating moisture content in transformer insulation using the results of FDS measurements. Based on the observations of this analysis a simplified model, called X model, was introduced in which the presence of spacers in transformer insulation has been neglected. Finally, reliability of the X model was assessed by comparing estimates of moisture contents based on FDS measurements on field installed power transformers with moisture contents obtained from chemical analyses of their oil samples.

Effect of Impurities on Streaming Electrification in Transformer Oil (변압기 절연유의 유동대전현상에 미치는 불순물의 영향)

  • Cho, Moon-Ho;Kweon, Dong-Jin;Kwak, Hee-Ro;Kim, Du-Suck
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.931-933
    • /
    • 1992
  • The static charges generated at the interface between the insulating oil and the solid materials, can be affected by impurities such as moisture. This paper investigated the charging tendency of clean oil and the oil with moisture in stainless steel pipe. The experimental results show that static electrification of the oil with moisture is smaller than that of the clean oil, and the oil is positively charged.

  • PDF