원전 습분분리재열기 튜브 번들 교체를 위한 열전달 고찰 (Heat Transfer Study to Replace a Tube Bundle of Moisture Separator Reheater at Nuclear Power Plant)

  • 최유성;최광희;이상국
    • 한국압력기기공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.65-71
    • /
    • 2010
  • The plugging rate of reheater tubes of Wolsung unit 1 nuclear power plant has been increased by corrosion and erosion since 1990. As the dimensions of the new first stage reheater bundle tubes which were supplied by Hanjung company to replace were different from old one, numerical calculations are carried out for flow and heat transfer in the reheater bundle tubes of the N.P.P. Numerical calculations consists of thermal performance, drain line pressure drop, flow change by pressure drop of line, stress analysis of finned tubes and analysis of flow induced vibration. Computational analysis using heat transfer research institute program is adopted to verify the results of the numerical calculations. It contains the evalution of performance in the system with view to location of the new reheater bundle and it shows the differences between the numerical calculation results and heat transfer research institute program output.

  • PDF

원자력발전소 습분분리재열기 튜브 원격장검사 기술 개발 (Development of Remote Reld Testing Technique for Moisture Separator & Reheater Tubes in Nuclear Power Plants)

  • 남민우;이희종;김철기
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.339-345
    • /
    • 2008
  • 원자력발전소 열교환기 튜브의 대부분은 구리, 티타늄, 인코넬합금 등의 비자성체로 제작되어 있으나 2차 터빈계통의 습분분리재열기(moisture separator & reheater), 급수가열기 등의 튜브는 고압, 고온 등의 열악한 운전조건에서 상대적으로 고온 강도가 우수한 탄소강 또는 페라이트계열 스테인레스강 등의 자성체로 제작되어 있다. 특히 습분분리재열기 튜브와 같은 열교환 매체가 증기인 경우 열전달 능력을 증가시키기 위해서 핀 튜브를 사용한다. 탄소강 또는 페라이트계열 스테인레스강 등의 자성체 튜브는 고온, 고압에서 강도가 우수하지만 운전 중에 증기 커팅, 침식, 기계적 진동 마모, 응력부식균열 등의 사용 중 결함이 발생하여 발전소 정상운전에 지장을 초래할 수 있기 때문에 전열관의 건전성 평가를 위한 주기적인 비파괴검사의 수행이 필요하다. 하지만 자성체 열교환기 튜브는 투자율이 높은 전기적 특성으로 인하여 기존의 와전류검사기술로는 비파괴검사가 어렵기 때문에 원격장검사기술을 적용해야 한다. 따라서 본 연구에서는 원자력발전소 습분분리재열기세관의 현장적용에 필요한 검사기술을 개발하기 위해서 원격장탐촉자, 인공결함 시험편 및 탐촉자 구동장치를 설계하였으며, 이를 활용하여 발전소 현장 검사에 적용하였다.

복합아민 적용에 따른 원전 2차 계통 부식생성물 거동평가 (Evaluation of Corrosion Product Behavior in NPP Secondary System with Complex Amine)

  • 정현준;이인형;김영인
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.96-99
    • /
    • 2014
  • The aim of the study was to evaluate the water treatment of pressurized water reactor secondary side by the mixed amine of ammonia and ethanolamine, from the standpoint of corrosion control, as compared with all volatile treatment of ammonia. The pressurized water reactor systems have switched a secondary side pH control agent to minimize the corrosion in the moisture separator/reheater and feedwater heater systems and the transport of corrosion products into steam generator. As results of field test, pH was increased in the steam generator and the wet steam area of moisture separator/reheater and the concentration of Fe were decreased by more than 50% as compared with water treatment of ammonia.

습분분리재열기 배수관 진동저감방안 (Vibration Reduction Method for Discharge Line of Moisture Separator Reheater)

  • 이준신;손석만;김태룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.