• 제목/요약/키워드: Module Unit

검색결과 829건 처리시간 0.027초

전통한옥 '칸'의 계획과 구성에 관한 연구 (A Study on Planning and Composition of Module Unit in Korean Traditional House)

  • 김종훈
    • 한국주거학회논문집
    • /
    • 제23권4호
    • /
    • pp.41-48
    • /
    • 2012
  • The purpose of the study, approaching from the aspect of the construction technologies, is to determine the architectural techniques of traditional wood architects in existence, through which the systems and techniques that create the inherent characteristics of Korean Architecture are clarified. With understanding traditional construction system and focusing on the fact that built environment results from the consistent standards and technologies of architects, this study inquires into the systematic standard and its formation that present in the process of planning for the overall scale and shape of a building from the following (four) perspectives. The study determines the characteristics of '間(Kan)' (unit; fundamental unit that measures Korean traditional houses) and the methods of columns disposition of which the '間 (Kan)' is made up. Once the necessary spaces are decided according to the size of a building, then floor plans are drawn with the standard unit, '間(Kan)'. The '間(Kan)', as a modular unit, is not only composing the floor plans, but also functioning as an Area unit, Space unit and Structural unit. Composition of '間(Kan)' varies with disposition of columns, and therefore multiform of floor and spaces are created. In this study, the '間(Kan)', as a standard unit, is used in the form of specific size and area, and it is demonstrated how the floor plans are developed by organizing the columns in accordance with the spaces requested.

도면검토를 통한 유닛 모듈러 주택의 문제점 유형분류 (Classification problems of the unit modular housing through reviewing design drawings)

  • 이유리;김균태;박남천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.160-161
    • /
    • 2014
  • This paper describes the classification problems of the unit modular housing through reviewing design drawings. Modular construction is a new industrialized homebuilding technology that uses large, factory produced modules. In general, more than 70% of construction processes in unit modular construction method are produced in factory after that the modular, which is completed is lifted on site and assembled. This research considers categorization in which the design drawing of the unit module housing can have problems. There are 17 types of construction method and 14 types of design approach as a result of the classification.

  • PDF

FRONT-END TELEMETRY DATA ACQUISITION UNIT FOR KSLV-I UPPER STAGE

  • Jung Hae-Seung;Kim Joonyun;Lee Jae-Deuk
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.337-340
    • /
    • 2004
  • Upper stage telemetry system of KSLV- I (Korea Space Launch Vehicle I) is composed of MDU (Master Data Unit), RDU (Remote Data Unit), SRU (Shock Recorder Unit) and Transmitter. RDU is the front-end telemetry data acquisition unit which gathers analog/discrete signals from various sensors and other units, and transmits the processed data to MDU via MIL-STD-I553B data bus. In order to acquire useful data from analog signal, signal conditioning circuits, such as anti-aliasing or amplifying, should be implemented. For this purpose, SCM (Signal Conditioning Module) had been developed. This paper describes hardware structure of SCM and analog signal conditioning circuits for various sensors. Also, sampling time scheme for different sampling rates were designed and tested.

  • PDF

Advanced JTAG-based On-Chip Debugging Unit Design for SoC

  • Yun Yeonsang;Kim Seungyoul;Kim Youngdae;You Younggap
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.61-65
    • /
    • 2004
  • An on-chip debugging unit is proposed aiming performance enhancement of JTAG-based SoC systems. The proposed unit comprises a JTAG module and a core breaker. The IEEE 1149.1 standard has been modified and applied to the new JTAG module. The proposed unit eliminates redundant clock cycles included in the TAP command execution stage reducing overall debugging time. TAP execution commands are repeatedly issued to perform debugging of complicated SoC systems. Simulation on the proposed unit shows some $14\%$ performance enhancement and $50\%$ gate count reduction compared to the conventional ones.

  • PDF

픽셀 배치가 자유로운 임베디드 LED 전광판 모듈 및 제어장치 설계 (A Design of Embedded LED Display Board Module and Control Unit which the Placement of Pixels is Free)

  • 이배규;김정화
    • 전자공학회논문지
    • /
    • 제50권10호
    • /
    • pp.135-141
    • /
    • 2013
  • 본 논문에서는 적색, 녹색, 청색의 세 가지 고휘도 LED를 하나의 소켓에 설치하여, 하나의 화소체 단위를 만들고, 이 화소체들의 조합과 다수 모듈들의 조합으로 문자, 그래픽, 동영상 등의 다양한 영상을 표출할 수 있는 풀컬러 전광판 모듈 및 제어장치를 개발하였다. LED 전광판 드라이버 모듈은 일정한 단위 면적에 RGB 픽셀을 조합한 도트에 드라이버 회로가 내장된다. 기존의 이러한 모듈형태는 특정 공간 및 설치 공간에 고정된 해상도를 구현하므로 가격이 높게 책정될 수 있다. 이러한 단점을 극복하기 위하여 임의의 피치 간격으로 배열이 자유로운 LED 드라이버 및 이에 따른 LED 픽셀 모듈을 개발하였다. 본 논문의 전광판 모듈은 기존 각각의 LED 모듈을 구동함에 있어서 병렬 방식의 데이터 처리 방식을 픽셀을 기준으로 그 위의 서브 모듈과 그 상위에 마스터 모듈의 개념을 도입하고 각각의 화소를 직병렬 통신 방식으로 개선함으로 인해서 처리할 수 있는 데이터의 속도를 초당 36프레임 이상으로 끌어올려서 상대적으로 데이터의 처리량이 많은 동화상의 경우에도 원활한 디스플레이를 할 수 있도록 하였다. 또한 기존 전광판의 깜박거림 현상이 개선되어 보다 선명한 영상이 제공되는 효과도 있다.

친환경 농촌마을계획을 위한 재생에너지 활용방안 연구 - 태양에너지 자원분석 - (A Study on Application of New & Renewable Energy for Environmental-friendly Planning of Rural Villages - Analysis of Solar Energy Resources -)

  • 남상운;김대식
    • 한국농공학회논문집
    • /
    • 제50권3호
    • /
    • pp.105-112
    • /
    • 2008
  • Solar energy, which is one of renewable energy, would be the most useful resources that can be applied to making energy recycling villages without using fossil energy. This study analyzed energy potential on solar energy considering weather condition in three traditional villages and compared with energy consumption surveyed. A photovoltaic system having 3.0kWp capacity of unit module can generate 182.5%, 96.1% and 170.9% of the yearly mean consumption of electric power in Makhyun, Boojang, and Soso, respectively. A flat-plate solar collector having $2.64m^2$ area of unit module can generate warm water of $142{\ell}$/day, $89{\ell}$/day, and $173{\ell}$/day, respectively in three study villages. In Makhyun and Soso, photovoltaic power and warm water produced by solar energy were sufficient to supply required amount of electric power and warm water. However, both electric power and warm water produced by unit solar module were not sufficient in Boojang area, and so it is required to increase the module area by more than 50%. According to the results of this study, the appropriate combination of energy resources can be applied to rural green-village planning if the characteristic of energy potential for each local area is considered.

GFRP 교량 바닥판의 정적거동에 관한 연구 (A Study on the Static Behavior of GFRP Bridge Deck)

  • 지효선
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권3호
    • /
    • pp.163-170
    • /
    • 2011
  • 본 연구에서 교량바닥판용으로 조립식(Modular) 유리섬유 보강(GFRP) 바닥판의 개념을 제안하였다. 본 조립식 GFRP 바닥판시스템은 GFRP 주 단위모률(unite module)과 연결 단위모듈로 구성되어 있다. 본 GFRP 바닥판의 구조성능을 평가하기 위해 정적하중실험을 실시하였다. 그리고 구조성능 결과에 대해서 범용 유한요소 프로그램인 LUSAS을 이용한 수치해석 결과와 비교 분석하였다. 본 연구에서 제안한 조립식 GFRP 바닥판은 교량적용에 매우 유용할 수 있음을 확인할 수 있었다. 제안된 GFRP 바닥판의 파괴모드가 개발된 다른 상용화된 GFRP 바닥판의 파괴모드와 매우 유사한 파괴모들 나타내었다.

RF front-end Module for On-Line UHF Partial-discharge Monitoring System

  • Lee June Young;Kim Bok Ki
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.776-779
    • /
    • 2004
  • A RF front-end module is designed for GIS(Gas Insulated Substation) which is employed for effective and efficient very high voltage transmission. Major advantage of the unit is improved PO detection sensitivity through minimizing the effect of surrounding interference signals, which is achieved by controlling the gain and the selection of the frequency band, for the precise detection of any UHF PO (Partial Discharge) disturbance occurred in the GIS due to some unwanted problems. For the development of the module, various switches for providing selected signal paths, wideband LNA, 3 BPF for selecting detection frequency band, and video detector are designed, fabricated and measured on 1 mm FR4 substrate with various RF components. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PO signals as low as 1 pC. It is believed that the value is enough to detect the signal occurred in GIS.

  • PDF

소형 모듈 스택을 이용한 가정용 연료전지 성능의 실험적 고찰 (An Experimental Study of Short Stack on the Performance of the Proton Exchange Membrane Fuel Cell for the Residential Power generation)

  • 최원석;김용모;유상석;이영덕;홍동진;안국영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.21-24
    • /
    • 2008
  • Proton Exchange Membrane Fuel Cell (PEMFC) is an attractive candidate for residential power generator due to fast start-up and stop, high efficiency, low emission, and high power density. In this study, we employ short module stack to understand the performance of the unit cell of the stack in terms of operating temperatures. To simulate the practical fuel cell stack of residential power generator, the structure and active area of the short module stack is kept the same as that of the practical fuel cell. The results shows that the electric potential of short module stack is different from the number of cells times the potential of unit cell because of cell-to-cell variation.

  • PDF

28 GHz 상향 및 하향변환기 설계기술 개발 (Design Technology Development of the 28 GHz Up and Down Converters)

  • 나채호;우동식;김강욱
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.366-370
    • /
    • 2003
  • This paper introduces a new design and fabrication technology of 28 GHz low-cost up and down converter modules for digital microwave radios, The design of the converter module is based on unit circuit blocks, which are to be characterized using a special test fixture. Based on the cascade analysis of the module the 28 GHz up and down converter modules have been designed and implemented. The measured module performance agrees with the cascade analysis. New components such as a tapped edge-coupled filter and a new Ka-band waveguide-to-microstrip transition, which are less sensitive to fabrication tolerances, have been used in the module implementation.

  • PDF