A Study on the Application of Modular Construction Method for Demand Responsive Dormitory Facilities (수요대응형 기숙사시설을 위한 모듈러공법 적용 방안)

  • Kim, Han Eol;Lim, Hyoung Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.259-260
    • /
    • 2021
  • Currently, the school-age population continues to decline in Korea due to social factors. On the other hand, the dormitory facilities are constantly being built and renovated. There are many problems such as construction period and on-site waste when constructed with reinforced concrete structures, which are existing construction methods. Accordingly, dormitory facilities shall be constructed using appropriate construction methods. Therefore, in this study, we will collect and organize basic data on the use status and modular system of dormitory facilities and study efficient maintenance and management when modular construction method is applied to dormitory facilities with changing demand.

  • PDF

Design Strength of Non-symmetric Composite Column for Modular Unit Frames (모듈러 유닛 골조용 비대칭 합성기둥의 설계강도)

  • Park, Keum-Sung;Lee, Sang-Sup;Moon, Ji-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.101-109
    • /
    • 2018
  • Modular structural systems have been used increasingly for low- and mid-rise structures such as school and apartment buildings. Studies have recently been conducted on the application of the modular structural system to high-rise buildings. To provide sufficient resistances and economical construction for the high-rise modular structural system, a composite unit modular structure was proposed. In this study, the strength of the non-symmetric composite column for the proposed composite unit modular structure was investigated through a series of tests. The experimental study focused on the effect of the slenderness of the column, eccentricity, and through bars on the strength of such a column. Design equations for the non-symmetric column for a modular unit structure were also proposed. From the results, it was found that the proposed design equations provide reasonable strength prediction of the non-symmetric composite column for the modular unit structure.

Test Result on Embedded Steel Column-to-Foundation Connection for Modular Unit Structural System (유닛 모듈러 기둥 매입형 기초 접합부에 대한 실험 연구)

  • Lee, Sang Sup;Bae, Kyu Woong;Park, Keum Sung;Hong, Sung Yub
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.537-547
    • /
    • 2014
  • A steel modular unit structural system has been used increasingly for mid and high-rise buildings, since the building can be easily constructed by assembling the pre-made modular unit structures. For this structural system, each modular unit structures have to be properly connected to the foundation to transfer the axial force and the bending moment that are generated from external load to the ground. In this study, a new type of the embedded steel column-to-foundation connection was proposed, and its flexural behavior was evaluated through a series of experimental study. Five full scale specimens for the proposed connections were constructed and tested. The effect of the main parameters that affect the flexural behavior of the proposed connection, such as embedment length and shape of end plate, were studied. From the results, it was found that the flexural stiffness of the proposed connection was higher than that of the semi-rigid connection for all test specimens, and 200 mm of embedment length was proper for the given test specimens in this study.

Connection Behavior of FRP Box Member of Connection Method (연결방법에 따른 FRP 박스 부재의 연결거동 특성)

  • Jang, Hwa-Sup;Kim, Ho-Sun;Kwak, Kae-Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.455-463
    • /
    • 2010
  • This is a basic experimental study to apply FRP modular box member to a variety of construction structures exposed to flexural strength, such as a slab and a girder. Tests were conducted under various conditions in order to analyze jointing performance features of the developed FRP modular box member as a large section. For the methods of jointing FRP modular box member, chemical connection, mechanical connection, and a combination of both were used to test both vertical and horizontal jointing. As a result of the test, using urethane+two bolts+sheets was the most efficient method of connecting FRP modular box member, and confirmed the efficient behavior by a finite element analysis.

ON THE MODULAR FUNCTION $j_4$ OF LEVEL 4

  • Kim, Chang-Heon;Koo, Ja-Kyung
    • Journal of the Korean Mathematical Society
    • /
    • v.35 no.4
    • /
    • pp.903-931
    • /
    • 1998
  • Since the modular curves X(N) = $\Gamma$(N)\(equation omitted)* (N =1,2,3) have genus 0, we have field isomorphisms K(X(l))(equation omitted)C(J), K(X(2))(equation omitted)(λ) and K(X(3))(equation omitted)( $j_3$) where J, λ are the classical modular functions of level 1 and 2, and $j_3$ can be represented as the quotient of reduced Eisenstein series. When N = 4, we see from the genus formula that the curve X(4) is of genus 0 too. Thus the field K(X(4)) is a rational function field over C. We find such a field generator $j_4$(z) = x(z)/y(z) (x(z) = $\theta$$_3$((equation omitted)), y(z) = $\theta$$_4$((equation omitted)) Jacobi theta functions). We also investigate the structures of the spaces $M_{k}$($\Gamma$(4)), $S_{k}$($\Gamma$(4)), M(equation omitted)((equation omitted)(4)) and S(equation omitted)((equation omitted)(4)) in terms of x(z) and y(z). As its application, we apply the above results to quadratic forms.rms.

  • PDF

The structural method of modular system expressed in contemporary fashion design (현대 패션디자인에 표현된 모듈러 시스템의 구조방식)

  • Yoon, Jeong-A;Lee, Younhee
    • The Research Journal of the Costume Culture
    • /
    • v.22 no.5
    • /
    • pp.776-793
    • /
    • 2014
  • This study attempted to figure out the usage of the modular system in other fields through literature review and empirical study, analyze its structural method in fashion. After analyzing architecture & product-related books, the Internet data and previous studies, the modular system's five structural methods were obtained. Then, 991 photos of women's clothes from 2003 to 2014 were collected through the fashion websites in Korea and abroad. The results can be summarized as follows: First, the following five structures were derived: assembling structure, overlapping structure, arrangement structure, inserting structure and folding structure. Second, according to analysis on the structural method of the modular system in modern fashion, overlapping structure (34%) was the most common. Third, in fashion, the use of fastener for installation and removal is important for assembling structure. In terms of overlapping structure, 3D volume by vertical accumulation was commonly observed. Arrangement structure revealed a horizontal and flat shape through simple arrangement. In inserting structure, on the contrary, non-standardized modules were used as a part of clothes or decorative elements. In folding structure, origami technique for reduction and expansion was used.

Experimental study of a pretensioned connection for modular buildings

  • Yu, Yujie;Chen, Zhihua;Chen, Aoyi
    • Steel and Composite Structures
    • /
    • v.31 no.3
    • /
    • pp.217-232
    • /
    • 2019
  • Modular steel buildings consist of prefabricated room-sized structural units that are manufactured offsite and installed onsite. The inter-module connections must fulfill the assembly construction requirements and soundly transfer the external loads. This work proposes an innovative assembled connection suitable for modular buildings with concrete-filled steel tube columns. The connection uses pretensioned strands and plugin bars to vertically connect the adjacent modular columns. The moment-transferring performance of this inter-module connection was studied through monotonic and cyclic loading tests. The results showed that because of the assembly construction, the connected sections were separated under lateral bending, and the prestressed inter-module connection performed as a weak semirigid connection. The moment strength at the early loading stage originated primarily from the contact bonding mechanism with the infilled concrete, and the postyield strength depended mainly on the tensioned strands. The connection displayed a self-centering-like behavior that the induced deformation was reversed during unloading. The energy dissipation originated primarily from frictional slipping of the plugin bars and steel strands. The moment transferring ability was closely related to the section dimension and the arrangements of the plugin bars and steel strands. A simplified strength calculation and evaluation method was also proposed, and the effectiveness was validated with the test data.

Lateral stiffness of corner-supported steel modular frame with splice connection

  • Yi-Fan Lyu;Guo-Qiang Li;Ke Cao;Si-Yuan Zhai;De-Yang Kong;Xuan-Yi Xue;Heng Li
    • Steel and Composite Structures
    • /
    • v.48 no.3
    • /
    • pp.321-333
    • /
    • 2023
  • This paper proposes a comprehensive investigation on lateral stiffness of corner-supported steel modular frame using splice connection. A full-scale modular frame with two stacked steel modules under lateral load is tested. Ductile pattern in the transfer of lateral load is found in the final failure mode. Two types of lateral stiffness, including tangent stiffness and secant stiffness, are defined from the load-displacement due to the observed nonlinearity. The difference between these two types of stiffness is found around 20%. The comparisons between the experimental lateral stiffness and the predictions of classical methods are also conducted. The D-value method using hypothesis of independent case is a conservative option for predicting lateral stiffness, which is more recommended than method of contraflexural bending moment. Analyses on two classical short-rod models, including fix-rod model and pin-rod model, are further conducted. Results indicate that fix-rod model is more recommended than pin-rod model to simplify splice connection for simulation on lateral stiffness of modular frame in elastic design stage.

Influence of shear bolt connections on modular precast steel-concrete composites for track support structures

  • Mirza, Olivia;Kaewunruen, Sakdirat
    • Steel and Composite Structures
    • /
    • v.27 no.5
    • /
    • pp.647-659
    • /
    • 2018
  • Through extensive research, there exist a new type of connection between railway bridge girders and steel-concrete composite panels. In addition to conventional shear connectors, newly developed blind bolts have been recently adopted for retrofitting. However, the body of knowledge on their influence and application to railway structures has not been thoroughly investigated. This study has thus placed a particular emphasis on the application of blind bolts on the Sydney Harbour Bridge as a feasible alternative constituent of railway track upgrading. Finite element modeling has been used to simulate the behaviours of the precast steel-concrete panels with common types of bolt connection using commercially available package, ABAQUS. The steel-concrete composite track slabs have been designed in accordance with Australian Standards AS5100. These precast steel-concrete panels are then numerically retrofitted by three types of most practical bold connections: head studded shear connector, Ajax blind bolt and Lindapter hollow bolt. The influences of bolt connections on load and stress transfers and structural behaviour of the composite track slabs are highlighted in this paper. The numerical results exhibit that all three bolts can distribute stresses effectively and can be installed on the bridge girder. However, it is also found that Lindapter hollow bolts are superior in minimising structural responses of the composite track slabs to train loading.