• Title/Summary/Keyword: Modular Pier

Search Result 15, Processing Time 0.023 seconds

Seismic Performance of Column-Footing Connection of Modular Pier using CFT (CFT를 이용한 모듈러 교각 기둥-기초 연결부의 내진성능)

  • Kim, Ji Young;Kim, Ki Doo;Ma, Hyang Wook;Chung, Chul-Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.73-85
    • /
    • 2014
  • The CFT (Concrete Filled steel Tubes) column-footing connection is cast-in-place embedded type which provides simple construction procedure, low cost, and superior structural performance. In this study, CFT column-footing connection of modular pier is proposed and structural performance is evaluated by experimental tests. To evaluate structural performance of the CFT column-footing connection, a series of experimental tests were performed for the 4 specimens with different embedded depth. As a result of the quasi-static test, the specimen with 0.6D (0.6 times the outside diameter of steel tube) embedded depth showed relatively low ductility than other specimens with larger embedded depth due to cone failure of base concrete occurred during the lower loading step. On the contrary, cone failure of the base concrete was not observed in the specimens with larger embedded depth than 0.9D, but typical flexural failure in lower part of CFT column was observed. With the analyses of force-displacement curve, displacement ductility, and energy dissipation capacity, it is concluded that the rational range of embedded depth of the CFT column-footing connection is from 0.9D to 1.2D in view of good seismic performance.

Development and experimental study on cable-sliding modular expansion joints

  • Gao, Kang;Yuan, Wan C.;Dang, Xin Z.
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.795-806
    • /
    • 2017
  • According to the characteristics of continuous beam bridges, the relative displacement is too large to collision or even girder falling under earthquakes. A device named Cable-sliding Modular Expansion Joints(CMEJs) that can control the relative displacement and avoid collision under different ground motions is proposed. Working principle and mechanical model is described. This paper design the CMEJs, establish the restoring force model, verify the force model of this device by the pseudo-static tests, and describe and analyze results of the tests, and then based on a triple continuous beam bridge that has different heights of piers, a 3D model with or without CMEJs were established under Conventional System (CS) and Seismic Isolation System (SIS). The results show that this device can control the relative displacement and avoid collisions. The combination of isolation technology and CMEJs can be more effective to achieve both functions, but it need to take measures to prevent girder falling due to the displacement between pier and beam under large earthquakes.

An Experimental Study on Development Connection System of Concrete Barrier in Modular Bridges (조립식교량의 콘크리트 방호울타리 연결시스템 개발을 위한 실험적 연구)

  • Jung, Ho Sung;Lee, Sang Seung;Choi, Jin Woong;Kim, Tae Wan;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.49-57
    • /
    • 2012
  • Recently, in field of bridge construction, modular technology has been studied to reduce construction period. However, main stream of the study is limited to the pier, girder and deck of bridge, which are huge or main members. Studies on incidental facilities like concrete barrier is out of sight. Thus, in this study, connection system of concrete barrier was developed to apply to modular bridges and static experiment was performed in order to verify structural capability of proposed system. Variables of experiment are composed of bolt direction such as vertical and horizontal. The experimentation due to the designed variables was conducted by comparison with a standard concrete barrier, which is a traditional barrier. As a result, vertical joint way of the bolt showed nearly identical structural performance and healthy to standard specimen's. it can be applied to modular bridges.

Safety Evaluation of Super Structure Member of Modular Pier In Coastal Zone (연안역 조립식 보도 잔교 상부구조 요소부재의 안전성 검토)

  • Yoo, Sang-Ryang;Park, Jong-Sup;Yoon, Ki-Yong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.848-851
    • /
    • 2012
  • 본 연구에서는 서해안의 지역적 특성을 고려한 말뚝지지형 조립식 잔교의 상부구조를 구성하는 요소 부재인 주거더 ㄷ형강과 가로보 및 가로거더 H형강에 대해 횡-비틀림 좌굴(Lateral-Torsional Buckling) 여부와 부재별 좌굴강도 값을 유한요소해석을 통해 산정하였으며, 산정한 좌굴강도 값과 부재에 작용하는 설계하중에 대한 안전성 검토를 하였다.

  • PDF

A Study on Method for The Reduction of Decreasing Strength of Concrete When Welding the Connection Part of Composite Structure Consist of Steel and Concrete (강과 콘크리트의 합성 부재 용접시 콘크리트 강도 저감 방지 기법 연구)

  • Won, Deok-Hee;Han, Taek-Hee;Lee, Dong-Jun;Kang, Young-Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.116-125
    • /
    • 2009
  • Recently, modular system are popular in construction fields, and they are increasing their marcket share. To compare modular units, bolting and welding are most popular methods. However, the temperature around a welded part might be over than 1,300$^{\circ}C and the composite member might be exposed tp the direct welding heat about 20,000$^{\circ}C. This high welding heat makes decrease of the concrete strength. If the concrete strength seriously decreases, it can affect the behavior and safty of a structure. On this study, To prevent of concrete strength decreases by welding heat, we suggested method of to insert between steel and concrete.