• 제목/요약/키워드: Modified push-out test

검색결과 11건 처리시간 0.02초

전단 연결재의 고온 성능 평가에 관한 연구 (A Study on the Slip Test of Shear Connector in Fire)

  • 한상훈;박원섭;이철호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.48-51
    • /
    • 2008
  • Shear connector is the element which resist in the horizontal shear force between steel and concrete of composite members and the stud bolt is often used because of its constructional convenience and serviceability. Although the push-out test is the most common method to evaluate shear slip behaviour, it is suitable for only room temperature conditions. In this study, we investigated about shear force, temperature distribution and slip displacement of shear connector in high temperature through the modified push-out test with electronic furnace invented for steel part heating.

  • PDF

Experimental studies of headed stud shear connectors in UHPC Steel composite slabs

  • Gao, Xiao-Long;Wang, Jun-Yan;Yan, Jia-Bao
    • Structural Engineering and Mechanics
    • /
    • 제74권5호
    • /
    • pp.657-670
    • /
    • 2020
  • Due to the high compressive and tensile strength of ultra-high performance concrete (UHPC), UHPC used in steel concrete composite structures provided thinner concrete layer compared to ordinary concrete. This leaded to the headed stud shear connectors embedded in UHPC had a low aspect ratio. In order to systematic investigate the effect of headed stud with low aspect ratio on the structural behaviors of steel UHPC composite structure s this paper firstly carried out a test program consisted of twelve push out specimens. The effects of stud height, aspect ratio and reinforcement bars in UHPC on the structural behaviors of headed studs were investigated. The push out test results shows that the increasing of stud height did not obviously influence the structural behaviors of headed studs and the aspect ratio of 2.16 was proved enough to take full advantage of the headed stud strength. Based on the test results, the equation considering the contribution of weld collar was modified to predict the shear strength of headed stud embedded in UHPC. The modified equation could accurately predict the shear strength of headed stud by comparing with the experimental results. On the basis of push out test results, bending tests consisted of three steel UHPC composite slabs were conducted to investigate the effect of shear connection degree on the structural behaviors of composite slabs. The bending test results revealed that the shear connection degree had a significantly influence on the failure modes and ultimate resistance of composite slabs and composite slab with connection degree of 96% in s hear span exhibited a ductile failure accompanied by the tensile yield of steel plate and crushing of UHPC. Finally, analytical model based on the failure mode of composite slabs was proposed to predict the ultimate resistance of steel UHPC composite slabs with different shear connection degrees at the interface.

스터드커넥터의 내화성능에 관한 연구 (Study on Fire Performance of Stud Connectors)

  • 김성배;한상훈;최승관
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.59-66
    • /
    • 2009
  • 본 연구는 합성구조에 사용되는 스터드커넥터의 화재시 성능에 대한 연구이다. 스터드커넥터는 전단연결재로 가장 폭넓게 사용되고 있으며, 콘크리트와 강재를 일체화시켜 합성 성능을 확보한다. 스터드커넥터에 대한 상세 내화성능은 아직 명확한 자료가 없으며, 향후 성능설계에서 무피복 합성보 등에 대한 설계 자료로 요구 된다. 본 실험의 스터드커넥터 성능시험은 푸시 아웃 실험을 변형하여 특수 전기로와 결합 ISO 표준온도곡선을 기본으로 거동 성능실험을 수행하였으며, 화재 조건의 파괴 형상을 기반으로 성능 분석 방법을 제안하였다.

Static push-out test on steel and recycled tire rubber-filled concrete composite beams

  • Han, Qing-Hua;Xu, Jie;Xing, Ying;Li, Zi-Lin
    • Steel and Composite Structures
    • /
    • 제19권4호
    • /
    • pp.843-860
    • /
    • 2015
  • Recycled tire rubber-filled concrete (RRFC) is employed into the steel-concrete composite structures due to its good ductility and crack resistance. Push-out tests were conducted to investigate the static behavior of steel and rubber-filled concrete composite beam with different rubber mixed concrete and studs. The results of the experimental investigations show that large studs lead a higher ultimate strength but worse ductility in normal concrete. Rubber particles in RRFC were shown to have little effect on shear strength when the compressive strength was equal to that of normal concrete, but can have a better ductility for studs in rubber-filled concrete. This improvement is more obvious for the composite beam with large stud to make good use of the high strength. Besides that the uplift of concrete slabs can be increased and the quantity and width of cracks can be reduced by RRFC efficiently. Based on the test result, a modified empirical equation of ultimate slip was proposed to take not only the compressive strength, but also the ductility of the concrete into consideration.

Light-gauge composite floor beam with self-drilling screw shear connector: experimental study

  • Erdelyi, Szilvia;Dunai, Laszlo
    • Steel and Composite Structures
    • /
    • 제9권3호
    • /
    • pp.255-274
    • /
    • 2009
  • This paper presents an experimental study of a newly developed composite floor system, built up from thin-walled C-profiles and upper concrete deck. Trapezoidal sheeting provides the formwork and the fastening of the sheet transmits the shear forces between the C-profiles and the deck. The modified formation of the standard self-drilling screw in the beam-to-sheet connection is applied as shear connector. Push-out tests are completed to study the composite behaviour of the different connection arrangements. On the basis of the test results the behaviour is characterized by the observed failure modes. The design values of the connection stiffness and strength are calculated by the recommendation of Eurocode 4. In the next phase of the experimental study six full-scale composite beams are tested. The global geometry is based on the proposed geometry of the developed floor system. The applied shear connections are selected as the most efficient arrangements obtained from the push-out tests. The experimental behaviour of the composite beams are discussed and evaluated. As a conclusion of the experimental study the Eurocode 4 plastic design method is validated for the developed composite floor.

Nonlinear numerical model of headed shear stud anchors for composite open web steel joists

  • Yanez, Sergio J.;Dinehart, David W.;Pina, Juan Carlos;Guzman, Carlos Felipe
    • Steel and Composite Structures
    • /
    • 제44권4호
    • /
    • pp.545-555
    • /
    • 2022
  • Empirical relationships that capture the nonlinear behavior of headed steel shear stud anchors have been derived from standard push out tests, where the specimens are comprised of large wide flanged steel sections attached to flat concrete slabs via the anchors. However, many composite systems used in practice utilize much smaller steel members and/or steel decking as part of the slab system. Composite open web steel joist systems generally include both of these elements and consequently the nonlinear performance ofthe anchor is not accurately represented by existing models. In this paper, a new empirical relation is presented for open web steel joist systems based on experimental results from a modified push out test that more realistically represent a composite open web steel joist system. The methodology for obtaining the proposed nonlinear function where the response of the system is characterized by two parameters(α and β) is presented. The two-step process for obtaining the two parameters is described and the empirical relation is calibrated with the experimental data. In comparison with existing expressions, the new proposal herein more accurately predicts the high initialstiffness of the system and overall nonlinear system performance.

Research on shear distribution of perfobond connector groups with rubber rings

  • Liu, Yangqing;Xin, Haohui;Liu, Yuqing
    • Steel and Composite Structures
    • /
    • 제38권4호
    • /
    • pp.399-414
    • /
    • 2021
  • This paper aims to verify the feasibility of rubber rings to mitigate the shear concentration in perfobond connector (PBL) groups. Firstly, modified push-out tests for five specimens with four holes were conducted to investigate the effects of rubber rings on the shear mechanism of PBL groups. The test results showed that by employing rubber rings on partial holes, more shear forces were distributed to the holes without rubber rings. The rubber rings significantly improved the slip ability of the specimens, and the ductility of PBL groups is dependent on the number and thickness of rubber rings. Subsequently, three-dimensional numerical models were established and validated by the experimental results. According to the plastic strain distribution in concrete dowels, the action principle of rubber rings in PBL groups was explained. Furthermore, the parametric study was conducted to investigate the influential factors on shear distributions, including the width of steel plates, the hole spacing, the number of holes, the rubber ring thickness, and the positions of rubber rings. The parametric analysis results showed that the redistribution of shear forces is significantly affected by the rubber rings with the smallest thickness. By properly employing rubber rings in PBL groups, the shear forces of holes are more even. Finally, an analytical model for PBL groups with rubber rings was proposed to predict the shear distribution at the serviceability stage.

파형전단연결재의 전단저항 성능 (Shear Capacity of Corrugated rib Shear Connector)

  • 안진희;최규태;김성현;김상효
    • 대한토목학회논문집
    • /
    • 제28권3A호
    • /
    • pp.375-381
    • /
    • 2008
  • 본 연구는 기존의 perfobond rib을 절곡시켜 변형시킨 형태인 corrugated rib 전단연결재의 전단강도를 평가하기 위하여 push-out 실험을 통하여 기존의 전단연결재인 stud, perfobond rib 전단연결재와 비교하였다. Corrugated rib 전단연결재의 전단강도에 기여하는 요인인 홀의 유무, 관통철근의 유무, 파형의 파고, rib의 높이 등을 고려하여 총 12본의 push-out 시험체를 제작하였다. 실험결과 corrugated rib 전단연결재 시험체는 콘크리트 슬래브의 지압성 파괴에 의하여 파괴 모드가 결정되었으며, 용접부의 파괴는 발생하지 않았다. 또한 corrugated rib 전단연결재가 perfobond rib 전단연결재보다 최대 96%의 전단저항 성능이 향상됨을 확인하였고, 관통철근의 배근유무에 따라 48%의 전단강도가 증가하는 것으로 나타났다. Corrugated rib 전단연결재의 홀 및 관통철근에 의해 콘크리트 다웰 효과가 증가되었으며, 파형의 파고 및 rib의 높이가 증가할수록 콘크리트 지압저항 영역의 증가로 인하여 전단강도가 증가하는 것을 확인할 수 있었다.

Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

  • Mirza, Olivia;Shil, Sukanta Kumer;Rashed, M.G.;Wilkins, Kathryn
    • Steel and Composite Structures
    • /
    • 제39권5호
    • /
    • pp.529-542
    • /
    • 2021
  • Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600℃. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600℃. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400℃. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

항공기 장착 무장의 투하 안정성 검증을 위한 지상무장분리시험 (Ground Ejection Tests to verify the Safe Separation of an Aircraft Mounted Store)

  • 이종홍;최석민;이민형;이철;정재원
    • 한국항행학회논문지
    • /
    • 제22권2호
    • /
    • pp.70-75
    • /
    • 2018
  • 항공기에 장착하는 무장은 실제 항공기에 장착하기 전에 안전 분리가 이루어졌음을 검증하기 위해 지상에서 무장분리시험을 실시해야 한다. 본 연구에서는 더미유도탄으로 지상에서투하 안정성을 검증하기 위한 지상무장분리시험을 실시하였다. 지상무장분리시험의 필수장비인 무장분리장치는 공압으로 동작하며 압력이 크고, 오리피스 직경이 클수록 유도탄을 밀어내는 사출력이 크게 발생한다. 무장분리장치의 봄베 압력과 오리피스 직경을 변경하여 더미유도탄의 투하 움직임을 고속카메라로 계측하였고 투하변위, 투하속도를 분석하였다. 실제 비행하는 항공기에서 무장 투하 해석시 기초 데이터를 제공할 수 있고, 추후 개발되는 항공기 무장의 지상무장분리시험 수행시 유용할 것으로 생각한다.