• 제목/요약/키워드: Modified electrode

검색결과 491건 처리시간 0.02초

Physioelectrochemical Investigation of Electrocatalytic Oxidation of Saccharose on Conductive Polymer Modified Graphite Electrode

  • Naeemy, A.;Ehsani, A.;Jafarian, M.;Moradi, M.
    • Journal of Electrochemical Science and Technology
    • /
    • 제6권3호
    • /
    • pp.88-94
    • /
    • 2015
  • In this study we investigated the electrocatalytic oxidation of saccharose on conductive polymer- Nickel oxide modified graphite electrodes based on the ability of anionic surfactants to form micelles in aqueous media. This NiO modified electrode showed higher electrocatalytic activity than Ni rode electrode in electrocatalytic oxidation of saccharose. The anodic peak currents show linear dependency with the square root of scan rate. This behavior is the characteristic of a diffusion controlled process. Under the CA regime the reaction followed a Cottrellian behavior and the diffusion coefficient of saccharose was found in agreement with the values obtained from CV measurements.

폴리피롤 막으로 변성시킨 유리질 탄소 및 백금 전극에서 Cr(Ⅵ) 이온의 정량 (Determination of Cr(Ⅵ) by Glassy Carbon and Platinum Electrodes Modified With Polypyrrole Film)

  • 유광식;우상범;정지영
    • 대한화학회지
    • /
    • 제43권4호
    • /
    • pp.407-411
    • /
    • 1999
  • 본 연구에서는 유리질 탄소전극과 백금 전극의 표면에 폴리피롤 막을 도포 시킨 PPy/GC 및 PPy/Pt 변성전극을 제조하고, 이들 변성 전극들을 작업전극으로 구성한 3-전극 장치를 이용하여 Cr(VI)의 정량분석을 시도하였다. 변성전극들은 +1.0V∼-1.0V를 50 mV/sec로 전위를 걸어주어 순환 전압 전류법으로 쉽게 제조할 수 있었으며, 26회 반복 주사함으로써 연구에 필요한 막의 두께를 조절하였다. PPy/GC 변성전극에서 Cr(VI)의 환원 반응은 +0.6V∼-0.5V(vs. Ag/AgCl)까지 넓은 범위에서 환원되는 경향을 보였으며,-0.25V(vs.Ag/AgCl)의 전위에서 최대 환원 봉우리를 가짐을 알 수 있었다. 이 전위에서 검량곡선을 조사한 결과, 0.1 ppm에서 60.0 ppm의 농도범위에서 기울기가 1.75 mA/ppm이고, 상관계수가 0.998인 좋은 직선관계를 가졌다. PPy/Pt 변성전극에서도 Cr(VI)의 환원 거동은 PPy/GC 변성전극과 유사하였으며, 검량곡선은 1.0 ppm∼60.0ppm의 농도범위에서 직선관계를 가졌다. 이때의 기울기와 상관계수는 각각 0.5 mA/ppm 및 0.923이었다. 그러나 선택성은 PPy/GC 변성전극이 약 3 배정도 우수하였다. PPy/GC 변성전극에서 Cu(II), As(III), pb(II) 및 Cd(II)등은 환원 경향을 보이지 않았으므로, Cr(VI)의 정량분석에는 방해하지 않았다.

  • PDF

Nanogold-modified Carbon Paste Electrode for the Determination of Atenolol in Pharmaceutical Formulations and Urine by Voltammetric Methods

  • Behpour, M.;Honarmand, E.;Ghoreishi, S.M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권4호
    • /
    • pp.845-849
    • /
    • 2010
  • A gold nanoparticles modified carbon paste electrode (GN-CPE) has been used for the determination of atenolol (ATN) in drug formulations by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronocoulometric methods. The results revealed that the modified electrode shows an electrocatalytic activity toward the anodic oxidation of atenolol by a marked enhancement in the current response in buffered solution at pH 10.0. The anodic peak potential shifts by -80.0 mV when compared with the potential using bare carbon paste electrde. A linear analytical curve was observed in the range of $1.96\;{\times}\;10^{-6}$ to $9.09\;{\times}\;10^{-4}\;mol\;L^{-1}$. The detection limit for this method is $7.3\;{\times}\;10^{-8}\;mol\;L^{-1}$. The method was then successfully applied to the determination of atenolol in tablets and human urine. The percent recoveries in urine ranged from 92.0 to 110.0%.

Glucose Oxidation on Gold-modified Copper Electrode

  • Lim, Ji-Eun;Ahn, Sang Hyun;Pyo, Sung Gyu;Son, Hyungbin;Jang, Jong Hyun;Kim, Soo-Kil
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2685-2690
    • /
    • 2013
  • The activities of Au-modified Cu electrodes toward glucose oxidation are evaluated according to their fabrication conditions and physico-chemical properties. The Au-modified Cu electrodes are fabricated by the galvanic displacement of Au on a Cu substrate and the characteristics of the Au particles are controlled by adjusting the displacement time. From the glucose oxidation tests, it is found that the Au modified Cu has superior activity to the pure Au or Cu film, which is evidenced by the negative shift in the oxidation potential and enhanced current density during the electrochemical oxidation. Though the activity of the Au nanoparticles is a contributing factor, the enhanced activity of the Au-modified Cu electrode is due to the increased oxidation number of Cu through the electron transfer from Cu to more electronegative Au. The depletion of electron in Cu facilitates the oxidation of glucose. The stability of the Au-modified Cu electrode was also studied by chronoamperometry.

수정된 바이폴라 전극을 갖는 착용형 심장활동 모니터링 시스템 구현 및 임상 심전도와의 상관관계 분석 (Implementation of Wearable Heart Activity Monitoring System having Modified Bipolar Electrode and Correlation Analysis with Clinical Electrocardiograph(ECG))

  • 이강휘;이정환;이영재;김경섭;양희경;신건수;이명호
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.1102-1108
    • /
    • 2008
  • Wearable physiological signal monitoring systems are regarded as an important sensing unit platforms in ubiquitous/mobile healthcare application. In this paper, we suggested the modified bipolar electrodes implemented on the portable heart activity monitoring system, which minimized the distance of electrodes formed on a attachable pad. The proposed electrode configuration is useful in mobile measurement environments, but has a disadvantage of reduced amplitude of the heart action potential. In order to overcome the shortcoming of the suggested electrode configuration, we implemented the amplifying circuit to increase the signal-gain and decrease the artifacts. For evaluations, we analyzed the specificity of measured cardiography using the proposed electrodes through the comparing of heart activity monitoring system with standard clinical ECG(lead2) by pearson correlation coefficients. The result showed that the average correlation coefficient is $0.903{\pm}0.036,\;0.873{\pm}0.072$ at V3, V4 chest lead position, respectively. Thus, the modified bipolar electrode is quite suitable to monitor the electrical activity of the heart in the situation of the mobile environment, and could be considered having high similarity with standard clinical ECG.

Lipid Film에 수식된 헤모글로빈의 전기화학적 특성과 $H_{2}O_{2}$응답특성 (Direct electrochemistry of hemoglobin at carbon electrode modified with lipid film and its application as a $H_{2}O_{2}$ sensor)

  • 이동윤;박상현;최용성;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.93-94
    • /
    • 2006
  • In this research, the enhancement of electron-transfer activity of hemoglobin (Hb) in dodecanoic acid film was investigated for the first time. This type of composite film was made on glassy carbon electrode by casting method. Cyclic voltammetric result of the modified electrode displays a well defined redox peaks which was attributed to the direct electrochemical response of Rb. Our results illustrate that Rb exchange electrons directly with electrode and exhibits the characteristics of peroxidase. When we apply this modified electrode as a biosensor, it gives excellent performances in the electrocatalytic reduction of hydrogen peroxide ($H_{2}O_{2}$). Through the optimal conditions, the proposed biosensor shows the linear range for H2O2 determination was from $1{\times}10^{-5}$ to $1.25{\times}10^{-4}mol/L$ with a detection limit of $1{\times}10^{-7}mol/L$. The biosensor retained more than 90% of the initial response after 14 days.

  • PDF

Electrochemical Detection of Self-Assembled Viologen Modified Electrode as Mediator of Glucose Sensor

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.106-110
    • /
    • 2009
  • An amperometric glucose biosensor has been developed using viologen derivatives as a charge transfer mediator between a glucose oxidase (GOD) and a gold electrode. A highly stable self-assembled monolayer (SAM) of thiol-based viologen was immobilized onto the gold electrode of a quartz crystal microbalance (QCM) and GOD was immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300mV. Upon immobilization of the glucose oxidase onto the viologen modified electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance, such as pH potential, were optimized and assessed. This biosensor offered excellent electrochemical responses for glucose concentration below ${\mu}$ mol level with high sensitivity and selectivity and short response time. The levels of the RSDs (<5%) for the entire analyses reflected the highly reproducible sensor performance. A linear calibration range between the current and the glucose concentration was obtained up to $4.5{\times}10^{-4}M$. The detection limit was determined to be $3.0{\times}10^{-6}M$.

Viologen 유도체를 전하전달체로 이용한 Glucose 센서의 $H_2O_2$ 검출 특성 ($H_2O_2$ Detection Property of Glucose Sensor using Self Assembled Viologen Modified Electrode as Mediator)

  • 이동윤;최원석;박상현;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.86-87
    • /
    • 2007
  • An amperometric glucose biosensor has been developed using viologen derivatives as electron mediator of glucose oxidase (GOD) at Au electrode. Highly stable self assembled monolayer (SAM) of thiol-based viologen is immobilized onto the Au electrode followed byGOD is immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300 mV. Upon immobilization of glucose oxidase onto the viologen modified-electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance such as, pH, potential were optimized and assessed. This biosensor offered an excellent electrochemical response for glucose concentration below ${\mu}mol$ level with high sensitivity and selectivity and short response time. The levels of the RSD's (< 5 %) for the entire analyses reflected the highly reproducible sensor performance. Using the optimized a linear relationship between current and glucose concentration was obtained up to $4.5{\times}10^{-4}$ M. In addition, this biosensor showed well reproducibility and stability.

  • PDF

점토광물을 이용한 산소환원의 전기화학적 촉매성에 관한 연구 (The Electrocatalytic Reduction of Molecular Oxygen with Clay Modified Electrodes)

  • 오성훈;황진연;심윤보;이효민;윤지해
    • 한국광물학회지
    • /
    • 제18권1호
    • /
    • pp.1-9
    • /
    • 2005
  • 몇 가지 점토광물과 메틸바이올로젠 또는 메틸렌블루를 함유시킨 점토수식전극을 이용하여 산소환원에 대한 전기화학적 촉매성을 검토하였다. 점토광물로는 Na-몬모릴로나이트, Ca-몬모릴로나이트, 카오리나이트를 사용하였다. 점토수식전극은 유리탄소전극 표면에 점토 현탁액을 입히고 메틸바이올로젠을 흡착시킨 것을 사용하였으며, 전기화학적 산소환원의 정도는 순환 전압전류법(cyclic voltammetry)으로 측정하였다. 실험결과, 다른 점토시료에 비하여 Na-몬모릴로나이트가 메틸바이올로젠의 흡착효과가 가장 크게 나타났고, 메틸바이올로젠을 흡착시킨 점토수식전극이 산소환원에 대한 촉매성이 월등히 우수하였다. 즉 촉매산소환원 피크가 242.6 mV 만큼 +방향으로 이동하였다. 메틸바이올로젠을 흡착시킨 점토수식전극이 메틸렌블루를 흡착시킨 점토수식전극보다 산소환원에 대한 촉매성이 더 높게 나타났다. Ca-몬모릴로나이트의 경우는 변화가 없었으나 Na-몬모릴로나이트의 구조는 메틸바이올로젠의 흡착으로 변화되었다. 메틸바이올로젠- Na-몬모릴로나이트 점토수식전극은 현탁액의 점토 농도가 약 0.87 g/10 mL이고. 메틸바이올로젠의 수용액의 농도가 대략 2.5 mM일 때 산소환원 촉매 효과가 가장 탁월하였다. 지지전해질의 pH에 따른 점토수식 전극의 산소 환원 촉매성은 중성의 pH 범위(6.3과 8.3)에서보다 산성인 pH 3.7과 알칼리성인 pH 12.7에서 월등히 크게 나타났다.

Bakelite A-Ni(II) 착물의 질산이온 선택성 막전극 (Nitrate Ion-Selective Membrane Electrode Based on Complex of Ammonia Modified Bakelite A-Ni(II) Nitrate)

  • 김환기;신두순
    • 대한화학회지
    • /
    • 제31권3호
    • /
    • pp.271-279
    • /
    • 1987
  • Amine기를 가진 Bakelite A와 Ni(II) 사이의 착물을 이용한 ${NO_3}^-$이온 선택성 막전극을 만들었다. 이 막전극은 $H^+$ 이온 및 2가 3가 음이온에는 감응하지 않으며, 특히 이 막전극의 재현성, 감응시간 및 이온선택성등 전기화학적 성질을 조사하여 다른 실용화된 막전극과 비교 고찰하였으며 분석화학에의 응용을 고찰하였다.

  • PDF