• Title/Summary/Keyword: Model wall test

Search Result 590, Processing Time 0.036 seconds

The Evaluation of Bearing Resistance of Underreamed Ground Anchor through Realistic Model Experiments (실모형실험을 통한 지압형 앵커의 지압력 평가)

  • Min, Kyongnam;Lee, Jaewon;Lee, Junggwan;Lee, Dongwon;Jung, Chanmuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.9
    • /
    • pp.87-92
    • /
    • 2014
  • The Ground anchor is reinforcement to resist pull-out through ground that is used supports structure. The pull-out resistance of anchor is constructed by skin friction resistance from compression borehole wall in expanded wings and bearing pressure from the ground. Especially, underreamed ground anchor is reinforcement that adopts active reinforcement to prevent deformation of ground using bearing resistance generated reaming anchorage. This study is conducted to calculate bearing resistance of underreamed ground anchor. Realistic model tests were fulfilled to determine bearing resistance of anchor, and correlate results of tests to Uniaxial Compressive Strengths (UCS) of ground models that assumed weathered rock condition in 8 case. In a comprehensive series of the tests, the bearing resistances were measured by pull-out tests. The bearing resistances derived from tests have a linear correlation with UCS. We also suggest empirical equation between bearing resistance and UCS of rocks by single linear regression analyses. In test results of this study, the bearing resistances were evaluated approximately 13 times higher than UCS of the grounds, and it is qualitatively similar to numerical values of pull-out force derived from theory.

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

Simulation Model of Two Dimensional Heat Transfer in Grain Bin (저장곡물(貯藏穀物) Bin내(內)의 삼차원(三次元) 열전달모형(熱傳達模型))

  • Han, Kwang Jin;Kim, Man Soo
    • Korean Journal of Agricultural Science
    • /
    • v.12 no.1
    • /
    • pp.118-127
    • /
    • 1985
  • The grain temperature is a crucial factor determining the deterioration rate of stored grain. Therefore, it is used to be predicted in order to evaluate the various stored methods rapidly and inexpensively. In this study, a mathematical model was developed to simulate the temperatures of grain stored in a cylinderical bin. It was formulated for the two dimensional heat transfer by the finite difference method. Then, it was verified statistically using the actual test deta and the predicted. The changes of grain temperature were analyed using the simulated data of one year for a safe stoarge and the following results were obtained: 1. Simulation model developed by the finite difference method was validated with the actual and the predicted grain temperatures and it's result showed that it could predict the grain temperature of storage bin reasonably well. 2. Grain temperature near the wall of storage bin were changed with $6-7^{\circ}C$ higher then average atmospheric temperature from June to September. Therefore, the parts of stored grain near the wall is supposed to be deteriorated fast. 3. When the dimension of bin diameter is about the same as the bed height, the changes of grain temperature of radial direction was higher than the verticals. 4. The predicted temperature showed that the grain temperature of which were from the end of April to mid October were higher than the safe storage limit at Yusung, Korea.

  • PDF

Study on the Fluid Dynamics Modeling in Artificial Lung Assist Device (인공 폐 보조장치 내에서의 유체 유동 모델링에 대한 연구)

  • Kim, Gi-Beum;Park, Young-Ran;Kim, Shang-Jin;Hong, Chul-Un;Kang, Hyung-Sub;Kim, Jin-Shang;Kim, Seong-Jong;Kim, Min-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.230-237
    • /
    • 2011
  • In this study, the characteristic of fluid flow in the new type lung assist devices has been established using computational fluid dynamics(CFD). For the modeling, the hollow fiber was ignored, and vertical types and tangential types were used for the model. Which was to analyze the flow characteristics of the fluid flow model when there exists 1 and 2 input/output ports, and when the input/output ports is located at the center of the cylinder and at the tangential direction with the cylinder wall. The modeling results showed that it was possible to eliminate no-flow region(stagnant layer) as shown in the vertical type when an inlet and an outlet were installed on the tangential direction of the cylinder as shown in the tangential type. Also, in the tangential type, vortex-type flow appeared as dominant, and it showed a complicated flow not deviated to one side. When the number of input/output was two, there was no deviated flow, and complicated flows were generated all across the tube. From the test result, it was found that input/output of flow was tangential type and complicated flows with no stagnant layer would be generated when there are two inputs/outputs, respectively.

Strut-and-Tie Model for Shear Strength of Reinforced Concrete Squat Shear Walls (저층형 철근콘크리트 전단벽의 전단강도 평가를 위한 스트럿-타이 모델)

  • Mun, Ju-Hyun;Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.615-623
    • /
    • 2015
  • The previous strut-and-tie models (STMs) to evaluate the shear strength of squat shear walls with aspect ratio less than 2.0 do not consider the axial load transfer of concrete strut and individual shear transfer contribution of horizontal and vertical shear reinforcing bars in the web. To overcome the limitation of the existing models, a simple STM was established based on the crack band theory of concrete fracture mechanics. The equivalent effective width of concrete strut having a stress relief strip was determined from the neutral axis depth and effective factor of concrete strength. The shear transfer mechanism of shear reinforcement at the extended crack band zone was calculated from an internally statically indeterminate truss system. The shear transfer capacity of concrete strut and shear reinforcement was then driven using the energy equilibrium in the stress relief strip and crack band zone. The shear strength predictions of squat shear walls evaluated from the current models are in better agreement with 150 test results than those determined from STMs proposed by Siao and Hwang et al. Furthermore, the proposed STM gives consistent agreement with the observed trend of the shear strength of shear walls against different parameters.

An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies (일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가)

  • Lee, Kyeong-Min;Yeom, Jeongkwan;Lee, Wonjae;Ryu, Seung-Hun;Park, Dongjin;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

A Study on the Restraint Effect on Lateral Displacement of an Inclined Earth Retaining Structure Integrated with Soil Nailing in Sandy Ground (사질토지반에 설치된 소일네일 복합형 IER의 수평변위 억제효과에 관한 연구)

  • Park, Tae-Keon;Im, Jong-Chul;Yoo, Jae-Won;Kim, Chang-Young;Kang, Sang-Kyun;Lee, Woo-Je
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.10
    • /
    • pp.33-47
    • /
    • 2017
  • A self-supported temporary excavation method called IER is normally applicable to excavation depth ranging from 6.0 m to 7.0 m though the method depends on ground condition and overburden load. Combining IER with another method is required in deeper excavation depth in order to maintain the structural stability of the IER. In this study, we performed model tests and 3D FE analysis to check the stability of the IER adopting soil nailing method, and to propose its effective installation method. The lateral displacement of the IER using soil nailing decreased by 92% of that of IER without soil nailing. Optimum design is possible for both economic feasibility and stability when interval spacing and length of soil nails is $1.5m(S_h){\times}0.75m(S_v)$ and 86% of excavation depth, respectively. Excavation depth using IER increases 1.71 times by adopting soil nailing in increment of lateral displacement of IER right before the last excavation stage.

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF

Development of Solar Warehouse for Drying and Storing the Agricultural Products (농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seob;Kim, Soung Rai;Jeon, Byeong Seon
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.357-370
    • /
    • 1982
  • Recent concern regarding price and availability of fossil fuels has spurred the interest in alternative sources for farm crop drying. Among the available options such as biomass energy, wind power, nuclear energy and solar energy etc., the increasing attention is being directed to the utilization of heat from solar energy especially for farm crop drying. Even though solar energy is dispersed over a large land area and only a relatively small amount of energy can be simply collected, the advantages of solar energy is that the energy is free, non-polluting. The study reported here was designed to help supply the informations for the development of simple and relatively inexpensive solar warehouse for farm crop drying and storage. Specifically, the objectives of this study were to determine the performance of the solar collector fabricated, to compare solar supplemented heat drying with natural air drying and to develop a simulation model of temperature in stored grain, which can be used to study the effects due to changes in ambient air temperature. For those above objectives, solar collector was fabricated from available materials. Corrugated steel galvanized sheet, painted flat black, was used as absorbers and clear 0.2mm polyethylene sheet was the cover material. The warehouse for rough rice drying and storage was constructed with concrete block, and the solar collector was used as the roof of warehouse instead of original roofing system of it. The results obtained in this study were as follows: 1. The thermal efficiency of the solar collector was average 26 percent and the overall heat transfer coefficient of the collector was approximately $25kJ/hr.m^2\;^{\circ}K$. 2. Solar heated air was sufficient to dry one cubic meter of rough rice from 23.5 to 15.0 percent in 7 days and natural air was able to dry the same amount of rough rice from 20.0 to 5 percent in l2 days. 3. Drying with solar heat reduced the required drying time to dry the same amount of rough rice into a half compared to natural air drying, but overdrying problems of the bottom layer were so severe that these problems should be thoroughly analyzed. 4. Simulation model of temperature in stored grain was developed and the results of predicted temperature agreed well with test results. 5. Based on those simulated temperature, changes in the grain-temperature were a large at the points of the wallside and the damage of the grain would be severe at the contact area of wall.

  • PDF

Validation of Equivalent Shear Beam Container Using Dynamic Centrifuge Tests (동적 원심모형실험을 이용한 등가전단보 토조의 성능 검증)

  • Kim, Yoon-Ah;Lee, Hae-In;Ko, Kil-Wan;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.61-70
    • /
    • 2020
  • In dynamic centrifuge tests, equivalent shear beam (ESB) container minimizes the boundary effect between the soil model and the wall of the container so as to effectively simulate the boundary conditions of real field state. The ESB container at KAIST was evaluated to be performing properly by Lee et al. (2013). However, it is necessary to re-evaluate the performance of ESB container since the ESB container may have deteriorated over time. Thus, the performance of eight-year-old ESB container was re-evaluated through dynamic centrifuge tests. Firstly, the natural period of the empty ESB container was compared with the results of Lee et al. (2013). Then the boundary effect of sand-filled ESB container was evaluated. Results show that the dynamic behavior of the sand-filled ESB container was similar to that of the ground, despite a decrease in the natural period of the empty ESB container over time. In addition, the dynamic response of the ground built in the ESB container and the same ground simulated through numerical analysis with free-field boundary conditions were similar. Therefore, it was found that the boundary effect of the ESB container due to the decrease in the natural period was not significant.