• Title/Summary/Keyword: Model wall test

Search Result 587, Processing Time 0.031 seconds

Wall Displacement of Geosynthetic Reinforced Soil Walls with Different Surcharge Loads - Model Test (상재하중 변화에 따른 토목섬유 보강토옹벽의 벽체변위)

  • Lee, Kwang-Wu;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.2
    • /
    • pp.41-47
    • /
    • 2008
  • This paper describes the results of model experiments in the laboratory, which were conducted to assess the behavior characteristics of geosynthetic reinforced soil walls according to different surcharge loads and reinforcement types. The model walls were built in the box having dimension, 100 cm tall, 140 cm long, and 100cm wide. Three types of geosynthetics, geonet, geogrid A and geogrid B, are used as the reinforcements. Decomposed granite soil (SM) was used as a backfill material. Seven model walls are constructed and tested. After the construction of the model wall, the LVDTs are installed to obtain the displacements of the wall face. As the results of the model tests, the maximum horizontal displacements of the model walls occurred due to uniform surcharge pressure were measured at the 0.7H from the bottom of the wall. The more the reinforcement strength increases, the more the wall displacements decrease, and also the reduction ratio of the wall displacement decrease with increasing the surcharge pressure.

  • PDF

Seismic performance of a 10-story RC box-type wall building structure

  • Hwang, Kyung Ran;Lee, Han Seon
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1193-1219
    • /
    • 2015
  • The purpose of this study is to evaluate the seismic performance of high-rise reinforced concrete (RC) box-type wall structures commonly used for most residential buildings in Korea. For this purpose, an analytical model was calibrated with the results of the earthquake simulation tests on a 1:5 scale 10-story distorted model. This calibrated model was then transformed to a true model. The performance of the true model in terms of the stiffness, strength, and damage distribution through inelastic energy dissipation was observed with reference to the earthquake simulation test results. The model showed high overstrength factors ranging from 3 to 4. The existence of slab in this box-type wall system changed the main resistance mode in the wall from bending moment to tension/compression coupled moment through membrane actions, and increased the overall resistance capacity by about 25~35%, in comparison with the common design practice of neglecting the slab's existence. The flexibility of foundation, which is also commonly neglected in the engineering design, contributes to 30~50% of the roof drift in the stiff direction containing many walls. The possibility of concrete spalling and reinforcement buckling and fracture under the maximum considered earthquake (MCE) in Korea appears to be very low when compared with the case of the 2010 Concepcion, Chile earthquake.

A rational estimating method of the earth pressure on a shaft wall considering the shape ratio (벽체형상비의 영향을 합리적으로 고려한 원형수직구 벽체에 작용하는 토압산정방법)

  • Shin, Young-Wan;SaGong, Myung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.2
    • /
    • pp.143-155
    • /
    • 2007
  • The earth pressure acting on a circular shaft wall is smaller than that acting on the wall in plane strain condition due to the three dimensional axi-symmetric arching effect. Accurate estimation of the earth pressure is required for the design of the shaft wall. In this study, the stress model considering the decrease of earth pressure due to the horizontal and vertical arching effect and the influence of shape ratio (shaft height/radius) is proposed. In addition, model test on the sandy soil is conducted and a comparison is made between the stress model and the test results. The comparison shows that the proposed stress model is in agreement with test results; decrease of shape ratio (increase of radius) leads to stress state equal to the plane strain condition and approximate stress distribution is found between stress model and model test results.

  • PDF

A study on the Optimum Design Configuration of Passive Solar TI-wall system (투명단열재가 적용된 축열벽 시스템의 최적구성 선정에 관한 연구)

  • Kim, Byoung-Soo;Yoon, Jong-Ho;Yoon, Yong-Jin;Baek, Nam-Choon
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.37-44
    • /
    • 2003
  • The aim of this study was to analyze the thermal performance through Test-Cell of TI-wall in domestic climate. This study was carried out as follows: 1) The TI-wall was studied for ability to reduce heat loss through the building envelope and analyzed to TIM properties. 2) Test models of TI-wall were designed through the investigation of previous paper and work, measured for winter and spring, and the thermal effects were analyzed. The type of the TIM used in test model is small-celled(diameter 4mm and thickness 50mm) capillary and cement brick(density $1500kg/m^3$) was used by thermal mass. 3) Test-cell of TI-wall was calibrated from measured data and the dynamic simulation program ESP-r 9.0. In these simulations, the measured climate conditions of TaeJon were used as outdoor conditions, and the simulation model of Test-cell was developed. 4) The sensitivity analysis is executed in various aspects with standard weather files and ESP-r 9.0, and then most suitable system of TI-wall are predicted. Finally, The suitable system of TI-wall was analysed according to sizes of air gap, kinds, thickness, and the surface absorption of therm wall. The result is following. In TI-wall, Concrete is better than cement brick, at that time the surface absorption is 95%, and the most efficient thickness is 250mm. As smaller of a air gap, as reducer of convection heat loss, it is efficient for heating energy. However, ensuring of a air gap at least more than 50mm is desirable for natural ventilation in Summer.

Model Test for The Behavior of Reinforced Earth Wall Associated with Surcharge Load (상재하중의 영향에 따른 보강토옹벽의 거동에 관한 모형실험연구)

  • 김명호;황의석;이봉렬;김학문
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.79-86
    • /
    • 2000
  • Recently, application of the reinforced earth wall is in increasing trend. Although many investigations on the influence of the length and spacing of reinforcement and the values of surcharge load has been carried out in the past, but the research about the influence of the location and value of surcharge loads has been scarce. Therefore this study was necessitated. The model test were carried out by varying the location and value of surcharge loads for two types of the backfill soils.

  • PDF

Seismic responses of a metro tunnel in a ground fissure site

  • Liu, Nina;Huang, Qiang-Bing;Fan, Wen;Ma, Yu-Jie;Peng, Jian-Bing
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.775-781
    • /
    • 2018
  • Shake table tests were conducted on scaled tunnel model to investigate the mechanism and effect of seismic loadings on horseshoe scaled tunnel model in ground fissure site. Key technical details of the experimental test were set up, including similarity relations, boundary conditions, sensor layout, modelling methods were presented. Synthetic waves and El Centro waves were adopted as the input earthquake waves. Results measured from hanging wall and foot wall were compared and analyzed. It is found that the seismic loadings increased the subsidence of hanging wall and lead to the appearance and propagation of cracks. The values of acceleration, earth pressure and strain were greater in the hanging wall than those in the foot wall. The tunnel exhibited the greatest earth pressure on right and left arches, however, the earth pressure on the crown of arch is the second largest and the inverted arch has the least earth pressure in the same tunnel section. Therefore, the effect of the hanging wall on the seismic performance of metro tunnel in earth fissure ground should be considered in the seismic design.

Improved Effects of Reinforced Wall with Types of Connection Methods (보강재 연결 유.무에 따른 보강토옹벽의 보강효과)

  • 신은철;최찬용
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.67-76
    • /
    • 1998
  • The commonly used method to secure the stability of reinforced retaining structure is the reinfocement of backfill with connection attached or unattached to the geogrid type wall. Laboratory model tests for both cartes were conducted to investigate the effectiveness of geogridreinforcement, length of reinforcement inclusion, failure envelop, and the relationships between the face wall displacement and vertical settlement. The bearing capacity of each case was also determined. According to the model test results, geogrid-reinforced rigid wall is very effective for increasing the bearing capacity and reducing the displacement of retaining wall. The observed sliding line of model test is similar to the theoretical one.

  • PDF

Study on Bending and Shear Strength Setting of Full-scale Model Additional Walls for Additional Wall Test Bed Combined with PHC-W Pile Retaining Wall (PHC-W말뚝 흙막이와 결합된 지하증설벽체 테스트베드 구축을 위한 실대형 지하증설벽체의 휨강도 및 전단강도 설정 연구)

  • Woo, Jong Youl;Yoo, Choong Geon;Kim, Sung Su;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.7-17
    • /
    • 2018
  • Test bed additional wall combined with PHC-W pile retaining wall has been constructed. To determine the dimensions of test bed additional wall, bending and shear tests of full scale core members of additional wall were tested. Basement additional walls utilizing PHC-W pile retaining wall, which were developed by modifying the cross-section of PHC piles, were classified into the composite additional wall and the non-composite additional wall. Their tests were conducted to obtain bending strength and shear strength of basement additional walls ultilizing PHC-W pile retaining wall. Since bending strengths and shear strengths of the composite additional wall and the non-composite additional wall were similar, it could be confirmed that the non-composite additional wall could be applied instead of the composite additional wall. Full-scale model additional wall was 200 mm thick, thus the thickness of additional wall combined with PHC-W pile retaining wall could be reduced by 100~200 mm.

A Study on Effective Correction of Internal Drag and Wall Interference Using Response Surface in Wind Tunnel Test (풍동시험에서 반응면을 이용한 내부 항력 및 벽면 효과의 효율적 보정방안 연구)

  • Kim, Junemo;Lee, Yeongbin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.637-643
    • /
    • 2019
  • Wind tunnel testing for flow-through model is necessary for performance prediction of an aircraft with air-breathing jet engine. Internal drag correction and wall correction are performed to acquire preciser wind tunnel test data. Many test runs are generally required to correct internal drag and wall interference in wind tunnel test. In this study we investigated more effective correction schemes using the response surface method. Even though the number of tests required for these schemes was much smaller than that for conventional methods, the differences between corrections using these schemes and conventional methods were similar level with the uncertainty of measurement except for the data near the boundaries.

Shear Band Formation in Granular Materials with Different Particle Shapes behind a Retaining Wall

  • Zhuang, Li;Kim, Ukgie
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.9
    • /
    • pp.39-47
    • /
    • 2013
  • Local deformations in back filling materials of two sands and one glass bead with different particle shapes behind a rigid retaining wall were studied. Two kinds of boundary conditions were compared: active wall translation and active rotation of the wall about its toe. Effect of the speed of active wall translation was also investigated. The digital image correlation method was used to analyze local deformation developments inside the materials. Test results showed that particle shape and density mainly influence the inclination angle and width of the shear band. The general shear band pattern is strongly dependent on the wall movement mode, while it was little influenced by particle shape. Within a limited range of wall speed in this study, shear band became wider and local deformation became larger with increase of wall speed.