• 제목/요약/키워드: Model scan method

검색결과 168건 처리시간 0.029초

Determination of Epipolar Geometry for High Resolution Satellite Images

  • Noh Myoung-Jong;Cho Woosug
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.652-655
    • /
    • 2004
  • The geometry of satellite image captured by linear pushbroom scanner is different from that of frame camera image. Since the exterior orientation parameters for satellite image will vary scan line by scan line, the epipolar geometry of satellite image differs from that of frame camera image. As we know, 2D affine orientation for the epipolar image of linear pushbroom scanners system are well-established by using the collinearity equation (Testsu Ono, 1999). Also, another epipolar geometry of linear pushbroom scanner system is recently established by Habib(2002). He reported that the epipolar geometry of linear push broom satellite image is realized by parallel projection based on 2D affine models. Here, in this paper, we compared the Ono's method with Habib's method. In addition, we proposed a method that generates epipolar resampled images. For the experiment, IKONOS stereo images were used in generating epipolar images.

  • PDF

Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method

  • Jeong, Yoo-Geum;Lee, Wan-Sun;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.245-251
    • /
    • 2018
  • PURPOSE. To evaluate the accuracy of a model made using the computer-aided design/computer-aided manufacture (CAD/CAM) milling method and 3D printing method and to confirm its applicability as a work model for dental prosthesis production. MATERIALS AND METHODS. First, a natural tooth model (ANA-4, Frasaco, Germany) was scanned using an oral scanner. The obtained scan data were then used as a CAD reference model (CRM), to produce a total of 10 models each, either using the milling method or the 3D printing method. The 20 models were then scanned using a desktop scanner and the CAD test model was formed. The accuracy of the two groups was compared using dedicated software to calculate the root mean square (RMS) value after superimposing CRM and CAD test model (CTM). RESULTS. The RMS value ($152{\pm}52{\mu}m$) of the model manufactured by the milling method was significantly higher than the RMS value ($52{\pm}9{\mu}m$) of the model produced by the 3D printing method. CONCLUSION. The accuracy of the 3D printing method is superior to that of the milling method, but at present, both methods are limited in their application as a work model for prosthesis manufacture.

레이저 스캔 카메라 보정을 위한 성능지수기반 다항식 모델 (Performance Criterion-based Polynomial Calibration Model for Laser Scan Camera)

  • 백경동;천성표;김수대;김성신
    • 한국지능시스템학회논문지
    • /
    • 제21권5호
    • /
    • pp.555-563
    • /
    • 2011
  • 영상의 왜곡보정은 영상 좌표계(이미지)와 전역 좌표계(대상체)의 상관관계를 규정하는 것이다. 기존의 왜곡영상에 대한 보정은 카메라의 광학적 특성을 모델링하여 영상 좌표계와 전역 좌표계의 물리적 관계를 찾는 방식이 주를 이루고 있다. 본 논문에서는 성능 지수기반 다항식 모델을 이용하여 왜곡영상의 보정을 시도하였다. 성능지수기반 다항식 모델은 영상 좌표계와 전역 좌표계 사이의 상관관계를 다항식으로 가정한 후, 이미지와 대상체의 좌표 데이터와 성능지수를 이용하여 다항식 모델의 계수와 차수를 결정하는 방식이다. 제안한 성능지수기반 다항식 모델을 이용하여 기존의 왜곡영상을 보정방식이 가진 과대적합 문제와 같은 한계를 극복하고자 한다. 제안한 방법을 레이저 스캔 카메라로 획득한 2차원 영상에 적용하여 모델의 유효성을 검증하였다.

거울 및 단일 카메라를 이용한 3차원 발 스캐너 (A 3D Foot Scanner Using Mirrors and Single Camera)

  • 정성엽;박상근
    • 한국CDE학회논문집
    • /
    • 제16권1호
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.

The tap-scan method for damage detection of bridge structures

  • Xiang, Zhihai;Dai, Xiaowei;Zhang, Yao;Lu, Qiuhai
    • Interaction and multiscale mechanics
    • /
    • 제3권2호
    • /
    • pp.173-191
    • /
    • 2010
  • Damage detection plays a very important role to the maintenance of bridge structures. Traditional damage detection methods are usually based on structural dynamic properties, which are acquired from pre-installed sensors on the bridge. This is not only time-consuming and costly, but also suffers from poor sensitivity to damage if only natural frequencies and mode shapes are concerned in a noisy environment. Recently, the idea of using the dynamic responses of a passing vehicle shows a convenient and economical way for damage detection of bridge structures. Inspired by this new idea and the well-established tap test in the field of non-destructive testing, this paper proposes a new method for obtaining the damage information through the acceleration of a passing vehicle enhanced by a tapping device. Since no finger-print is required of the intact structure, this method can be easily implemented in practice. The logistics of this method is illustrated by a vehicle-bridge interaction model, along with the sensitivity analysis presented in detail. The validity of the method is proved by some numerical examples, and remarks are given concerning the potential implementation of the method as well as the directions for future research.

3차원 인체 형상을 이용한 실버 여성 패션 산업용 인대 모형 개발 (Development of Dress Forms for the Aged Women Based on Their Body Shapes Applying 3D Body Scan Data)

  • 김수아;최혜선
    • 복식문화연구
    • /
    • 제18권1호
    • /
    • pp.80-92
    • /
    • 2010
  • This research aims at developing the dress form for the aged women based on their body shapes using the three-dimensional body scan data with the body shape categorization(according to the previous research). To accomplish this goal, the sample group of representative body shape of the 50% of median was selected by using the high frequency proportion range of each type of body shape of the aged women, and the sample group of representative body shape of each type was averaged in a three-dimensional way by using the morphing method of a three-dimension reverse-engineered software. RP in the form of torso was produced based on the shape data of the final model and the data was formed into an actual object, by which an aged women's dress form model was drawn out. The differences of the girth of the bust, hip and waist between the developed dress form model and the existing dress form model were examined. The result showed that the developed dress form had a bigger size of waist girth than that of bust and hip girth, compared to the existing dress form, which shows that it reflects the aged women's tendency of abdomen obesity, so it's expected to be more proper for the human bodies of the targeted age group than the existing dress form. These research results may help design the clothing suitable for the body shape of the aged women so that their demand for the clothing of good fit will be satisfied in the future.

핸드스캐닝 작업 방법에 따라 표준 모델 변형이 작업 정밀도에 미치는 정밀스캔에 관한 연구 (A Study on the Accuracy of Scan by the Standard Model Deformation Depending on the Hand Scanning Method)

  • 신성훈;장성호;송준기;박광식;이희성
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.197-202
    • /
    • 2018
  • 본 연구는 치과분야에서 가장 큰 변화를 가져온 자동화 시스템의 보급화로 CAD/CAM이 사용됨에 따라, 로스트왁스 테크닉 기법 시스템을 대체 하고 있다. 이에 따라 인상재를 이용하여 구강을 채득하는 방법에서 구강스캐너를 활용하여 디지털 데이터로 치과보철물을 제작하고 있다. 그러나 구강스캐너의 스캐닝 방법에 따라 디지털 데이터의 정밀도가 많을 영향을 받고 있는 실정이다. 이에 본 연구의 목적은 구강스캐너 (Intraoral scanner)의 스캔 작업 방법에 따라 나타날 수 있는 왜곡현상 및 데이터 정확도를 평가하고자 한다. 데스탑 3D 모형 스캐너로 임상에서 사용된 석고 모델을 이용하여 표준 스캔 데이터를 만들고 동일한 모델을 사용하여 구강스캐너로 세 가지 다른 방법의(AS그룹, ZS그룹, OS그룹) 스캔 방법으로 구분하여 각 5회씩 그룹별로 스캔 데이터를 만들었고, ZS그룹에서 0.121mm, AS그룹 0.172mm, OS그룹 0.423mm 정확도를 보여 ZS그룹에서 가장 높은 정확도를 보였고, 최대오차 값은 ZS그룹 0.113mm, AS그룹 0.169mm, OS그룹 0.246으로 최대 오차는 ZS그룹이 가장 낮고 OS그룹이 가장 높게 측정되었다. 세 가지의 스캔 방법은 정확도나 재현성에 있어 확실한 차이를 보였으며 임상에서도 역시 의미 있는 결과로 보였다.

초음파 선형주사 영상을 위한 합성구경 기법의 해석 (Analysis of Synthetic Aperture Techniques for Ultrasound Linear - scan Imaging)

  • 송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권4호
    • /
    • pp.503-513
    • /
    • 1999
  • 본 논문에서는 일반적인 합성구경기법에 대한 통합 모형을 제시하고 수학적인 해석을 통하여 합성구경 기법들에 대한 초음파 빔패턴의 단일 표현식을 유도하였다. 이 결과를 이용하여 기존의 합성구경 기법들에 대한 성능을 분석하고 비교하였으며, 선형주사 영상에 적합한 새로운 합성구경 기법을 제안하였다. 제안된 방법은 모든 영상점에서 양방향 동적 집속이 가능하며, 이를 실제 영상에 적용하여 의료용 초음파 B-모드 영상의 해상도를 획기적으로 개선할 수 있다. 제안된 방법에 의하여 집속된 초음파 빔패턴은 기존의 방식과 비교하여 주엽의 폭이 절반으로 감소하고 측엽의 크기는 유사하다. 컴퓨터 모사실험을 통하여 본 논문의 해석결과와 제안된 합성구경 기법의 타당성을 검증하였다.

  • PDF

Efficient Triangulation Algorithm for Constructing the Model Surface from the Interpolation of Irregularly-Spaced Laser Scanned Data

  • 손호웅
    • 지구물리
    • /
    • 제8권3호
    • /
    • pp.153-157
    • /
    • 2005
  • A discussion of a method has been used with success in terrain modelling to estimate the height at any point on the land surface from irregularly distributed samples. The special requirements of terrain modelling are discussed as well as a detailed description of the algorithm and an example of its application.

  • PDF

스캔패턴 분석을 위한 레이더 수신신호 모델링 (Modeling of Received Radar Signals for Scan Pattern Analysis)

  • 김용희;김완진;송규하;이동원;김형남
    • 대한전자공학회논문지TC
    • /
    • 제47권4호
    • /
    • pp.73-85
    • /
    • 2010
  • 주파수, 펄스폭, 펄스반복주기 등의 정보를 식별변수로 이용하는 기존의 레이더 식별 기법들은 현대전의 고밀도 다중 신호환경에서 식별모호성이 발생하는 문제점을 가진다. 이러한 문제점을 극복하고 전자전 지원 시스템의 식별성능을 향상시키기 위해 레이더의 스캔패턴 정보를 활용하는 식별 기법에 관한 연구가 지속되고 있다. 이 과정에서 레이더 스캔패턴 정보와 다양한 수신환경을 반영하는 정확한 레이더 수신신호의 확보가 우선적으로 요구되나, 실제 전자전 환경에서 직접 수집하거나 모의환경을 구성하여 획득하는 방법은 현실적으로 많은 어려움이 있다. 이를 위해 본 논문에서는 실제 전자전 지원 시스템에서 수신되는 레이더 신호의 세기가 결정되는 과정을 모델링한 후, 이를 토대로 다양한 운용변수와 수신환경을 고려한 레이더 수신신호 생성 기법을 제안한다. 그리고 대표적인 스캔패턴에 대해 레이더 수신신호를 생성한 후 수신 위치에 따른 신호의 특성을 자세하게 분석한다.