• Title/Summary/Keyword: Model eye

Search Result 473, Processing Time 0.025 seconds

Fabrication of Ex vivo Cornea Model for a Drug Toxicity Evaluation (약물 독성 평가용 생체외 각막 모델 제작 연구)

  • Kim, Seon-Hwa;Park, Sang-Hyug
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.143-150
    • /
    • 2019
  • To evaluate the toxicity of ophthalmic drug, the Draize test and Bovine Corneal Opacity and Permeability (BCOP) test commonly used. In Draize test, experimental animals were under stress and pain due to long-term exposure of drug. In addition, regarding physiological functions, animal model is not perfectly reflected a human eye condition. Although some models such as $EpiOcular^{TM}$, HCE model, LabCyte Cornea-Model, and MCTT $HCE^{TM}$ were already presented advanced cornea ex-vivo model to replace animal test. In this sense, cornea tissue structure mimicked ex-vivo toxicity model was fabricated in this study. The corneal epithelial cells (CECs) and keratocytes (CKs) isolated from rabbit eyeball were seeded on non-patterned silk film (n-pSF) and patterned silk film (pSF) at $32,500cells/cm^2$ and $6,500cells/cm^2$. Sequentially, n-pSF and pSF were stacked to mimic a multi-layered stroma structure. The thickness of films was about $15.63{\mu}m$ and the distance of patterns was about $3{\mu}m$. H&E stain was performed to confirm the cell proliferation on silk film. F-actin of CKs was also stained with Phalloidin to observe the cytoskeletal alignment along with patterns of the pSF. In the results, CECs and CKs were shown the good cell attachment on the n-pSF and pSFs. Proliferated cells expressed the specific phenotype of cornea epithelium and stroma. In conclusion, we successfully established the ex-vivo cornea toxicity model to replace the eye irritation tests. In further study, we will set up the human ex-vivo cornea toxicity model and then will evaluate the drug screening efficacy.

A New Hand-eye Calibration Technique to Compensate for the Lens Distortion Effect (렌즈왜곡효과를 보상하는 새로운 hand-eye 보정기법)

  • Chung, Hoi-Bum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.172-179
    • /
    • 2002
  • In a robot/vision system, the vision sensor, typically a CCD array sensor, is mounted on the robot hand. The problem of determining the relationship between the camera frame and the robot hand frame is refered to as the hand-eye calibration. In the literature, various methods have been suggested to calibrate camera and for sensor registration. Recently, one-step approach which combines camera calibration and sensor registration is suggested by Horaud & Dornaika. In this approach, camera extrinsic parameters are not need to be determined at all configurations of robot. In this paper, by modifying the camera model and including the lens distortion effect in the perspective transformation matrix, a new one-step approach is proposed in the hand-eye calibration.

The effects of PEP-1-FK506BP on dry eye disease in a rat model

  • Kim, Dae Won;Lee, Sung Ho;Ku, Sae Kwang;Lee, Ji Eun;Cha, Hyun Ju;Youn, Jong Kyu;Kwon, Hyeok Yil;Park, Jong Hoon;Park, Eun Young;Cho, Sung-Woo;Han, Kyu Hyung;Park, Jinseu;Eum, Won Sik;Choi, Soo Young
    • BMB Reports
    • /
    • v.48 no.3
    • /
    • pp.153-158
    • /
    • 2015
  • As FK506 binding proteins (FK506BPs) are known to play an important role in the regulation of a variety of biological processes related to cell survival, this study was designed to examined the protective effects of FK506 binding protein 12 (FK506BP) on low humidity air flow induced dry eye in a rat model using transduced PEP-1-FK506BP. After the topical application of PEP-1-FK506BP, tear volumes were markedly increased and significant prevention of cornea damage was observed compared with dry eye rats. Further, immunohistochemical analysis demonstrated that PEP-1-FK506BP markedly prevented damage to the cornea, the bulbar conjunctiva, and the palpebral conjunctiva epithelial lining compared with dry eye rats. In addition, caspase-3 and PARP expression levels were found to be decreased. These results demonstrated that topical application of PEP-1-FK506BP significantly ameliorates dry eye injury in an animal model. Thus, we suggest that PEP-1-FK506BP can be developed as a new ophthalmic drop to treat dry eye diseases.

The Differences in Eye Movement of Pre-service Teachers and Elementary School Students in SBF Question about a Visual Material of the Change on the Lunar Phases (달 위상 변화의 시각화 자료에서 SBF 질문에 따른 예비교사와 초등학생의 시선 이동 차이)

  • Ko, Minseok;Yang, Ilho;Kim, Obeom;Lim, Sungman
    • Journal of Korean Elementary Science Education
    • /
    • v.33 no.2
    • /
    • pp.273-285
    • /
    • 2014
  • Purpose of this study is to analyze eye movements of pre-service teachers and elementary students about a visual material of the change on the lunar phases. Eye-Tracker was used for analysis for eye-fixation time and eye movement at the structure, behavior, function question on the visual material. The Results were as follows. First, the pre-service teacher checked the visual materials from a holistic perspective depending on the function questions and fixed eye-fixation on the moon of the behavior question concerned. On the contrary, elementary school student only checked function of the moon located in the upper part and eye-fixation focus was spread here and there regardless of the questions. Second, the pre-service teacher gazed at the sun, earth and moon in a consecutive order depending on the questions to identify their spatial relations and checked location of the moon related to the question. On the contrary, the elementary school student did not view relations between earth, sun and moon from a spatial perspective. These findings indicate that the pre-service teacher conjures up the mechanism of the change on the lunar phases and confirms it in visual materials by visualizing change on the lunar phase model from earth's point of view while the elementary school student fails to take advantage of visual materials to visualize it from earth's point of view.

Generation of Topographic Map Using GeoEye-1 Satellite Imagery for Construction of the Jangbogo Antarctic Station (GeoEye-1 위성영상을 이용한 남극의 장보고기지 건설을 위한 지형도 제작)

  • Kim, Eui-Myoung;Hong, Chang-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.4
    • /
    • pp.101-108
    • /
    • 2011
  • Construction of the Jangbogo antarctic station was planned, and it requires detailed information on topography of the area around the station. The purpose of this research is to generate the topographic map to construct the Jangbogo antarctic station using the satellite image. To do this, surveying and pre-test of equipment were conducted. In addition, for sensor modeling of the GeoEye-1 satellite image, RPC-bias correction was done, and it showed that at least two control points are required. In generating the map, a 1/2,500 scale was deemed suitable in consideration of resolution of the image and the fact that supplementary topographic surveying would be impossible. In order to provide detailed information on the topography around the Jangbogo station, the digital elevation model based on image matching was created, and compared with GPS-RTK data, accuracy of vertical location about 0.6m was exhibited.

A Study on the Eye-Hand Coordination for Korean Text Entry Interface Development (한글 문자 입력 인터페이스 개발을 위한 눈-손 Coordination에 대한 연구)

  • Kim, Jung-Hwan;Hong, Seung-Kweon;Myung, Ro-Hae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.149-155
    • /
    • 2007
  • Recently, various devices requiring text input such as mobile phone IPTV, PDA and UMPC are emerging. The frequency of text entry for them is also increasing. This study was focused on the evaluation of Korean text entry interface. Various models to evaluate text entry interfaces have been proposed. Most of models were based on human cognitive process for text input. The cognitive process was divided into two components; visual scanning process and finger movement process. The time spent for visual scanning process was modeled as Hick-Hyman law, while the time for finger movement was determined as Fitts' law. There are three questions on the model-based evaluation of text entry interface. Firstly, are human cognitive processes (visual scanning and finger movement) during the entry of text sequentially occurring as the models. Secondly, is it possible to predict real text input time by previous models. Thirdly, does the human cognitive process for text input vary according to users' text entry speed. There was time gap between the real measured text input time and predicted time. The time gap was larger in the case of participants with high speed to enter text. The reason was found out investigating Eye-Hand Coordination during text input process. Differently from an assumption that visual scan on the keyboard is followed by a finger movement, the experienced group performed both visual scanning and finger movement simultaneously. Arrival Lead Time was investigated to measure the extent of time overlapping between two processes. 'Arrival Lead Time' is the interval between the eye fixation on the target button and the button click. In addition to the arrival lead time, it was revealed that the experienced group uses the less number of fixations during text entry than the novice group. This result will contribute to the improvement of evaluation model for text entry interface.

Geometric Correction of Vehicle Fish-eye Lens Images (차량용 어안렌즈영상의 기하학적 왜곡 보정)

  • Kim, Sung-Hee;Cho, Young-Ju;Son, Jin-Woo;Lee, Joong-Ryoul;Kim, Myoung-Hee
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.601-605
    • /
    • 2009
  • Due to the fact that fish-eye lens can provide super wide angles with the minimum number of cameras, field-of-view over 180 degrees, many vehicles are attempting to mount the camera system. Camera calibration should be preceded, and geometrical correction on the radial distortion is needed to provide the images for the driver's assistance. However, vehicle fish-eye cameras have diagonal output images rather than circular images and have asymmetric distortion beyond the horizontal angle. In this paper, we introduce a camera model and metric calibration method for vehicle cameras which uses feature points of the image. And undistort the input image through a perspective projection, where straight lines should appear straight. The method fitted vehicle fish-eye lens with different field of views.

  • PDF

Optimum design of the finite schematic eye using spherical aberration (구면수차를 이용한 정밀모형안의 최적화)

  • 김상기;박성찬
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.266-271
    • /
    • 2002
  • The finite schematic eye based on spherical aberration and Stiles-Crawford effect is designed by an optimization method. It consists of four aspherical surfaces. The radius of curvature, thickness, asphericity, and spherical aberration are used as constraints in the optimization process. Stiles-Crawford effect in the pupil is considered as a weighting value for optimum design. The designed schematic eye has effective focal length of 20.8169 mm, back focal length of 15.4820 mm, front focal length of -13.8528 mm, and image distance of 15.7150 mm. When the pupil diameter is 4 mm, the diameter of entrance pupil and exit pupil are 4.6919 mm and 4.2395 mm, respectively. From the data of 75 measured Korean emmetropic eyes, this finite schematic eye is designed first in Korea.

Omni-directional Surveillance and Motion Detection using a Fish-Eye Lens (어안 렌즈를 이용한 전방향 감시 및 움직임 검출)

  • Cho, Seog-Bin;Yi, Un-Kun;Baek, Kwang-Ryul
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.79-84
    • /
    • 2005
  • In this paper, we developed an omni-directional surveillance and motion detection method. The fish-eye lens provides a wide field of view image. Using this image, the equi-distance model for the fish-eye lens is applied to get the perspective and panorama images. Generally, we must consider the trade-off between resolution and field of view of an image from a camera. To enhance the resolution of the result images, some kind of interpolation methods are applied. Also the moving edge method is used to detect moving objects for the object tracking.

Real-Time Eye Detection and Tracking Under Various Light Conditions (다양한 조명하에서 실시간 눈 검출 및 추적)

  • 박호식;배철수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.456-463
    • /
    • 2004
  • Non-intrusive methods based on active remote IR illumination for eye tracking is important for many applications of vision-based man-machine interaction. One problem that has plagued those methods is their sensitivity to lighting condition change. This tends to significantly limit their scope of application. In this paper, we present a new real-time eye detection and tacking methodology that works under variable and realistic lighting conditions. Based on combining the bright-Pupil effect resulted from IR light and the conventional appearance-based object recognition technique, our method can robustly track eyes when the pupils ale not very bright due to significant external illumination interferences. The appearance model is incorporated in both eyes detection and tacking via the use of support vector machine and the mean shift tracking. Additional improvement is achieved from modifying the image acquisition apparatus including the illuminator and the camera.