• 제목/요약/키워드: Mode of oscillation

검색결과 305건 처리시간 0.033초

한전 전력계통의 저주파 진동현상 요인분석;양수발전기 기동시 (Analysis of the Factors Affecting Low-Frequency Oscillations in KEPCO Power System` With Pumped-Storage Plant)

  • Kil Yeong Song;Sae Hyuk Kwon;Kyu Min Ro;Seok Ha Song
    • 대한전기학회논문지
    • /
    • 제41권8호
    • /
    • pp.841-849
    • /
    • 1992
  • In power system operation, the stability of synchronous machine has been recognized one of the most important things. AESOPS program developed by EPRI in U.S.A. is a frequency domain analysis program in power system stability and it computes the electro-mechanical oscillation mode. This paper presents how to analyze the power system small signal stability problem efficiently by uusing the AESOPS program and analyze the various factors affecting the damping characteristics of these oscillations in KEPCO power system of 1986 with pumped-storage plant. To reduce the computing time and efforts, selecting the poorly-damped oscillation mode and clustering technique have been used. The characteristics of load, the amount of power flow on the transmission line and the gain of exciter have a significant effects on the damping of the system while the governing system has only a minor one. With the Power System Stabilizers, the stability of the power system has been improved.

  • PDF

영동권~서해안 발전단지간 연계선로의 전력진동 제동력 향상을 위한 TCSC 적용방안 (TCSC control for Damping enhancement of intra-area Power Oscillation between Yeongdong and West sea power generation sites)

  • 허연;최진산
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.224-225
    • /
    • 2011
  • 전력진동(Power Oscillation)은 전력이 0.05 Hz ~ 3.0 Hz의 저주파로 진동하는 현상으로서 계통고장 등의 원인으로 의해 취약한 송전선로에서 발생된다. 전력진동의 종류에는 inter-area mode, intra-area mode, local mode 등이 있는데, 국내 전력계통에서는 향후 영동권 원자력단지와 충남 서해안 화력단지 간을 연결하는 초고압 송전선로에서 intra-area mode의 전력진동이 발생할 가능성이 있다. TCSC를 적용하여 전력진동 제동효과를 얻을 수 있다. 본 논문에서 국내 전력계통에 TCSC를 설치함으로써 전력진동이 효과적으로 감소됨을 보인다. simulation 결과, 전력진동이 5% 수준으로 대폭 감소됨을 알 수 있다.

  • PDF

A New Approach to HVDC System Control for Damping SSO Using the Novel Eigenvalue Analysis Program

  • Kim, Dong-Joon;Nam, Hae-Kon;Moon, Young-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.178-191
    • /
    • 2004
  • This paper presents a new approach to HVDC system control for damping subsynchronous oscillation (SSO) involving HVDC converters and turbine generator shaft systems. This requires a novel eigenvalue analysis (NEA) program, derivation of HVDC system modeling considering steady-state conditions and dynamic conditions in the combined AC/DC system, and an appropriate control scheme. The method suggested makes possible the design of a subsynchronous oscillation damping controller (SODC) to provide positive damping torque for the range of torsional modes in combined AC/DC systems. There are three steps involved in the design of a SODC; first the worst torsional mode is determined using the NEA program, next the SODC parameters are designed for the range of that torsional mode, and then finally an off-line simultaneous time domain program such as PSCAD/EMTDC is used to verify the parameters of the SODC. The suggested SODC design method is applied to two AC/DC systems, and its practicality is verified using the PSCAD/EMTDC simulation program.

In situ cavity loss measurements of a mode-locked erbium-doped fiber ring laser by thed relaxation oscillation frequency method

  • Jhon, Young-Min;Kim, Bong-Kyu;Kim, Dong-Hwan;Kim, Myong-Wook;Kim, Sang-Kuk;Choi, Sang-Sam
    • Journal of the Optical Society of Korea
    • /
    • 제4권1호
    • /
    • pp.11-13
    • /
    • 2000
  • We experimentally measured the cold cavity loss of a mode-locked erbium-doped fiber ring laser in situ by using the relaxation oscillation frequency method. The relaxation oscillation frequency is measured for various pumping powers and the data is fitted by the least squares method with a theoretical curve of parameters including the cavity loss. We obtained a cavity loss of 15.3$\pm$0.5 dB which was found to agree with the results of direct transmission loss measurements.

Single Mode Laser Oscillation in an Nd-Doped Large Core Double Clad Fiber Cavity with Concatenated Adiabatic Tapers

  • Seo, Hong-Seok;Choi, Yong-Gyu;Kim, Kyung-Hon;Jeong, Hoon;Oh, Kyung-Hwan
    • ETRI Journal
    • /
    • 제24권3호
    • /
    • pp.255-258
    • /
    • 2002
  • We created a new design for an Nd-doped clad-pumped silica fiber laser to enhance the pump absorption and lasing efficiency for a butt-coupled, end-pumped scheme. Two concatenated adiabatic tapers formed within the laser cavity simultaneously removed higher order modes and were spliced to conventional single mode fibers. We theoretically analyzed mode propagation along the composite cavity and experimentally achieved continuous wave oscillation in the $LP_{01}$ mode at $1.06\;{\mu}m$ and a laser output power of over 820 mW with a slope efficiency of 27%.

  • PDF

K-band 도파관을 이용한 대전력 마이크로파 출력장치 연구 (A Study of High Power Microwave Output by K-band Waveguide)

  • 김원섭
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.588-591
    • /
    • 2009
  • We had experimental studies of microwave output generator. We experimented with a corrugate-shped K-band slow wave guide in the backward wave oscillator. It generated output 표 interaction between electron beam's generation and magnetic field. We estimated oscillation frequency at 24GHz by changing propagation velocity and group velocity. We identified movement by second harmonic of Cherencov interaction and slow cyclotron mode. In our study we achieved oscillation stabilization, generation of long pulse, improvement of oscillation efficiency and output.

Empirical Mode Decomposition (EMD) and Nonstationary Oscillation Resampling (NSOR): II. Applications in Hydrology and Climate sciences

  • Lee, Tae-Sam;Ouarda, TahaB.M.J.;im, Byung-Soo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2011년도 학술발표회
    • /
    • pp.91-91
    • /
    • 2011
  • In the present study, the proposed EMD and NSOR models has been applied in hydrology and climate sciences. Here, we present those applications as the following: (1) to extend future scenarios of Global Surface Temperature Anomaly including long-term oscillation component; (2) to extend the future evolution of the Eastern Canada winter precipitation; (3) to apply EMD in detecting climate change.

  • PDF

연속적 라비 진동과 불연속적 양자도약의 양립성 (Compatibility of Continuous Rabi Oscillation and Discontinuous Quantum Jumps)

  • 조영탁;김기식
    • 한국광학회지
    • /
    • 제23권2호
    • /
    • pp.77-86
    • /
    • 2012
  • 양자물리학적 패러다임이 발견된 이래, 라비(Rabi) 진동과 같은 전자(electron)의 에너지 준위 간 연속적인 천이(transition)와 보어(Bohr) 모형으로 대표되는 불연속적 양자 도약(quantum jump)의 상충성(incompatibility)은 현재까지도 서로 자연스럽게 연결하기가 어려운 오랜 개념적 어려움으로 남아 있다. 본 연구에서는 그러나, 빛과 물질의 상호작용을 기술하는 현대적 이론 중의 하나인 양자궤적이론(quantum trajectory theory)의 관점에서 단일 모드 공진기 장(single mode cavity field)과 상호작용하는 단일 원자의 행동을 관찰한 바, 원자-장 간 상호작용의 강도(strength)가 줄어듦에 따라서 원자의 행동이 연속적 라비 진동으로부터 불연속적 양자도약의 양상으로 점진적으로 변화하여 가는 과정을 발견하고, 이 단순하면서도 흥미로운 현상에 대하여 보고한다.

부스팅 모드에서 IRR(Integral Rocket Ramjet) 초음속 흡입구의 압력진동 감쇄 방안 연구 (A Study of Preventing Pressure Oscillation for Supersonic Inlet of IRR at the Boosting Mode)

  • 박근홍;윤현걸;임진식
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.563-564
    • /
    • 2010
  • IRR의 부스팅 모드 시 흡입구에 발생하는 압력진동을 감쇄하기 위한 방안을 수치적으로 연구하였다. 축대칭 형태의 초음속 흡입구에 slit을 장착하여 유입되는 공기 유량을 줄여가며 흡입구 내부의 압력 진동을 조사하였다. 흡입되는 유량이 감소함에 따라 압력의 진폭은 감소하고 내부 압력의 최댓값 역시 감소하였으며, 주파수는 약간 증가하는 경향을 보였다. 흡입구의 slit을 이용하여 최적화된 압력 진폭과 주파수대를 얻어낼 수 있다면, 이 방안은 IRR의 부스팅 모드 및 천이 모드에서의 안정성을 높이는데 활용될 수 있을 것으로 판단된다.

  • PDF

Synchrophasor를 이용한 한전계통의 저주파 진동 해석 초기 결과 (Initial Results of Low Frequency Oscillation Analysis based on Synchrophasor in KEPCO System)

  • 심관식;김상태;남해곤;최준호
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.1-9
    • /
    • 2014
  • The parameters of electromechanical modes offer considerable insight into the dynamic stability properties of a power system. This paper describes an initial result for extraction of dynamic parameters from synchrophasor measurements collected on the KEPCO system. Dominant modes of the system are estimated by oscillation detecting program in K-WAMS. The critical wide-area modes of KEPCO system have frequencies in the 0.4 to 0.7Hz range. And the local mode causing the low frequency oscillation of generators located on the west coast area has in the frequency 0.97 and 1.25 Hz, respectively. This results can serve as a reference in the future for reliable system operation in KEPCO system.