• 제목/요약/키워드: Mode of failure

검색결과 2,213건 처리시간 0.025초

Analytical study of the failure mode and pullout capacity of suction anchors in sand

  • Liu, Haixiao;Peng, Jinsong;Zhao, Yanbing
    • Ocean Systems Engineering
    • /
    • 제5권4호
    • /
    • pp.279-299
    • /
    • 2015
  • Suction anchors are widely adopted and play an important role in mooring systems. However, how to reliably predict the failure mode and ultimate pullout capacity of the anchor in sand, especially by an easy-to-use theoretical method, is still a great challenge. Existing methods for predicting the inclined pullout capacity of suction anchors in sand are mainly based on experiments or finite element analysis. In the present work, based on a rational mechanical model for suction anchors and the failure mechanism of the anchor in the seabed, an analytical model is developed which can predict the failure mode and ultimate pullout capacity of suction anchors in sand under inclined loading. Detailed parametric analysis is performed to explore the effects of different parameters on the failure mode and ultimate pullout capacity of the anchor. To examine the present model, the results from experiments and finite element analysis are employed to compare with the theoretical predictions, and a general agreement is obtained. An analytical method that can evaluate the optimal position of the attachment point is also proposed in the present study. The present work demonstrates that the failure mode and pullout capacity of suction anchors in sand can be easily and reasonably predicted by the theoretical model, which might be a useful supplement to the experimental and numerical methods in analyzing the behavior of suction anchors.

D대학 수변전설비의 고장모드 영향 분석 (Failure Modes and Effects Analysis for Electric Power Installations of D University)

  • 박영호;김두현
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.7-15
    • /
    • 2016
  • The purpose of this paper is to carry out Failure Modes and Effects Analysis (FMEA) and use criticality in order to determine risk priority number of the components of electric power installations in Engineering college building of D university. In risk priority number, GROUP A had 7 failure modes; more specifically, Transfomer had 4 modes, Filter(C)(1 mode), LA(1 mode), and CB(MCCB)(1 mode), and thus 4 components had failure modes. In terms of criticality, high-grade group a total of 16 failure modes, and 7 components-LA(1 mode), CB(MCCB)(1 mode), MOF(2 modes), PT(1 mode), Transformer(7 modes), Cable(3 modes), and Filter(C)(1 mode)-had failure modes. Comparison of risk priority number and criticality was made. The components which had high risk priority number and high criticality were Transformer, Filter(C), LA, and CB(MCCB). The components which had high criticality were MOF and cable. In particular, Transformer(RPN: 4 modes, Criticality: 7 modes) was chosen as an intensive management component.

머시닝센터의 고장모드 해석에 관한 연구 (A Study on Failure Mode Analysis of Machining Center)

  • 김봉석;김종수;이수훈;송준엽;박화영
    • 한국정밀공학회지
    • /
    • 제18권6호
    • /
    • pp.74-79
    • /
    • 2001
  • In this study, a failure mode analysis of CNC machining center is described. First, the system is classified through subsystems into components using part lists and drawings. The component failure rate and failure mode analysis are performed to identify the weak components of a machining center with reliability database. The failure probabilistic function of mechanical part is analyzed by Weibull distribution. The Kolmogorov-Smirnov test is also used to verify the goodness of fit.

  • PDF

공작기계의 신뢰성 평가를 위한 고장 모드 해석에 관한 연구 (A Study on Failure Mode Analysis for Reliability Assesment of Machining Center)

  • 이수훈;김종수;김봉석;송준엽;이승우;박화영;박종권
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.1010-1013
    • /
    • 2000
  • In this study, a failure mode analysis of CNC machining center is described. At first, the system is classified through subsystems into components using part lists and drawings. The components failure rate and failure mode analysis are performed to identify the weak components of a machining center with reliability database. The failure probabilistic function of mechanical part is analyzed by Weibull distribution. The Kolmogorov-Smirnov test is also used to verify the goodness of fit.

  • PDF

실리콘 태양전지 모듈의 two-mode failure 모델의 연구 (A Study of Two-Mode Failure Model for Crystalline Si Photovoltaic Module)

  • 최기영;오원욱;강병준;김영도;탁성주;김동환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.62.2-62.2
    • /
    • 2011
  • To guarantee 20-25 years to the lifetime of the PV modules without failure, reliability test of the module is very important. Field-aged test of the outdoor environment is required. However, due to time constraints, accelerated testing is required to predict the lifetime of PV modules and find causes of failure. Failure is caused by many complex phenomena. In this study, we experimented two accelerated tests about corrosion and fatigue, respectively. First, temperature cycling test for fatigue were tested and Coffin-Manson equation was analyzed. Second, damp heat test for corrosion were tested and Eyring equation were analyzed. Finally, using two-mode failure model, we suggest a new lifetime model that analyze the phenomenon by combining two kinds of data.

  • PDF

A numerical investigation of the tensile behavior of the thread-fixed one-side bolted T-stubs at high temperature

  • You, Yang;Liu, Le;Jin, Xiao;Wang, Peijun;Liu, Fangzhou
    • Steel and Composite Structures
    • /
    • 제45권4호
    • /
    • pp.605-619
    • /
    • 2022
  • The tensile behavior of the Thread-fixed One-side Bolt (TOB) at high temperatures was studied using the Finite Element Modeling (FEM) to explore the structural responses that could not be measured in tests. The accuracy of the FEM was verified using the test results from the failure mode, load-displacement curve as well as yielding load. Three typical failure modes of TOB connected T-stubs were observed, which were the Flange Yielding (FY), the Bolt Failure (BF) and the Coupling Failure mode (CF). The influence of the flange thickness tb and the temperature θ on the tensile behavior of the T-stub were discussed. The initial stiffness and the yielding load decreased with the increase of the temperature. The T-stubs almost lost their resistance when the temperature exceeded 700℃. The failure modes of T-stubs were mainly decided by the flange thickness, which relates to the anchorage of the hole threads and the bending resistance of flange. The failure mode could also be changed by the high temperature. Design equations in EN 1993-1-8 were modified and verified by the FEM results. The results showed that these equations could predict the failure mode and the yielding load at different temperatures with satisfactory accuracy.

오류유형 영향분석(FMEA)을 적용한 수술준비 위험예방활동의 효과 (A Study on Failure Mode and Effect Analysis (FMEA) for Preoperative Risk Prevention)

  • 김창희;이미향
    • 간호행정학회지
    • /
    • 제22권5호
    • /
    • pp.415-423
    • /
    • 2016
  • Purpose: The purpose of this research was to provide patients with safe preoperative preparatory procedures by removing any risk factors from the preparatory procedures by using failure mode and effects analysis, which is a prospective risk-managing tool. Methods: This was a research design in which before and after conditions of a single group were studied, Failure mode and effects analysis were applied for the preparatory procedures done before operations. Results: The preparation omission rate before the operation decreased from 2.70% to 0.04%, and operation cancellation rate decreased from 0.48% to 0.08%. Conclusion: Failure mode and effects analysis which remove any risk factors for patients in advance of the operation is effective in preventing any negligent accidents.

다수의 고장모드를 가지는 기계부품의 신뢰성 분석 (Reliability Analysis of Mechanical Component with Multiple Failure Modes)

  • 장무성;최병오;강보식;박종원;이충성
    • 대한기계학회논문집A
    • /
    • 제37권9호
    • /
    • pp.1169-1174
    • /
    • 2013
  • 대부분의 제품은 다수의 고장모드를 가지지만, 일반적으로 신뢰성 분석에서 고장모드 별로 분석하는 경우는 많지 않다. 또는 신뢰성 분석 시 고장모드에 대한 정보를 제공하지 않거나 대표적인 고장모드로 분석하기도 한다. 특히 신뢰성 인증시험에서 가정하고 있는 형상모수는 제품의 형상모수보다는 고장모드에 대한 형상모수 값이 더 중요하다. 본 연구에서는 다수의 고장모드를 가지는 기계부품에 대한 신뢰성 분석방법으로 경쟁 고장모드 분석방법과 혼합 와이블 분석방법을 소개한다. 그리고 3 가지 고장모드를 가지는 공기압 실린더의 사례에 대해 각 고장모드 별로 형상모수를 구하였으며, 3 가지 고장모드를 고려했을 때와 하나의 고장모드로 가정했을 때의 신뢰성 측도($B_{10}$ 수명, 특성 수명)을 비교하였다.

Crack pattern and failure mode prediction of SFRC corbels: Experimental and numerical study

  • Gulsan, Mehmet Eren;Cevik, Abdulkadir;Mohmmad, Sarwar Hasan
    • Computers and Concrete
    • /
    • 제28권5호
    • /
    • pp.507-519
    • /
    • 2021
  • In this study, a new procedure was proposed in order to predict the crack pattern and failure mode of steel fiber reinforced concrete (SFRC) corbels. Moreover, an experimental study was carried out in order to investigate the effect of several parameters, such as compressive strength, tensile strength, steel fiber ratio, shear span on the mechanical behavior of SFRC corbels in detail. Totally, 24 RC and SFRC corbels were prepared for the experimental study. Experimental results indicate that each investigated parameter has noticeable effect on the load capacity and failure mode of SFRC corbels. Moreover, finite element (FE) model of the tested corbels were prepared and efficiency of FE model was investigated for further studies. Comparison of FE and experimental results show that there is an acceptable fit between them regarding load capacity and crack patterns. Thereafter, parametric study was carried out via FE analyses in order to obtain a methodology for crack pattern and failure mode prediction of SFRC corbels. As a result of parametric studies, a new procedure was proposed as flowcharts in order to predict the failure mode of SFRC corbels for normal and high strength concrete class separately.

혼합하중 조건하에서 갈색산화물이 입혀진 구리계 리드프레임/EMC 계면의 파손경로 (Failure Path of the Brown-oxide-coated Copper-based Leadframe/EMC Interface under Mixed-Mode Loading)

  • 이호영
    • 한국표면공학회지
    • /
    • 제36권6호
    • /
    • pp.491-499
    • /
    • 2003
  • Copper-based leadframe sheets were oxidized in a hot alkaline solution to form brown-oxide layer on the surface and molded with epoxy molding compound (EMC). The brown-oxide-coated leadframe/EMC joints were machined to form sandwiched double-cantilever beam (SDCB) specimens and sandwiched Brazil-nut (SBN) specimens for the purpose of measuring the fracture toughness of leadframe/EMC interfaces. The SDCB and the SBN specimens were designed to measure the fracture toughness of the leadframe/EMC interfaces under nearly mode-I loading and mixed-mode (mode I + mode II) loading conditions, respectively. Fracture surfaces were analyzed by various equipment such as glancing-angle XRD, SEM, AES, EDS and AFM to elucidate failure path. Results showed that failure occurred irregularly in the SDCB specimens, and oxidation time of 2 minutes divided the types of irregular failures into two classes. The failure in the SBN specimens was quite different from that in the SDCB specimens. The failure path in the SBN specimens was not dependent on the phase angle as well as the distance from tips of pre-cracks.