• Title/Summary/Keyword: Mode of failure

Search Result 2,213, Processing Time 0.038 seconds

Comparison of metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture (상악 총의치 정중 파절 수리 시 금속선 및 유리섬유의 보강효과 비교)

  • Lee, Jung-Ie;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.284-291
    • /
    • 2013
  • Purpose: This study compared fracture strength and fracture modes between metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture. Materials and methods: In this study, fracture was reproduced on center of maxillary complete dentures and the denture was repaired with auto-polymerizing resin. The experimental groups (n = 10) were subjected to the following condition: without reinforcing material (control group), reinforcing with metal wire (W group), reinforcing with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheon, Korea, G group). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The Kruskal-wallis test and the Mann-whitney U test were performed to identify statistical differences at ${\alpha}=.05$. Results: W group showed the highest value of fracture strength, there was no significant difference (P>.05) between control group and G group. Control group and W group showed anteroposterior fracture mainly, group W showed adhesive fracture of denture base and reinforcing material. Conclusion: In limitation of this study, the glass fiber did not improve the fracture strength of repaired maxillary complete denture, and adhesive failure was occurred along the lines of glass fiber.

Dentin bond strength of bonding agents cured with Light Emitting Diode (LIGHT EMITTING DIODE로 광조사한 상아질 접착제의 상아질 전단접착강도와 중합률에 관한 연구)

  • Kim Sun-Young;Lee In-Bog;Cho Byeong-Hoon;Son Ho-Hyun;Kim Mi-Ja;Seok Chang-In;Um Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.504-514
    • /
    • 2004
  • This study compared the dentin shear bond strengths of currently used dentin bonding agents that were irradiated with an LED (Elipar FreeLight, 3M-ESPE) and a halogen light (VIP, BISCO). The optical characteristics of two light curing units were evaluated. Extracted human third molars were prepared to expose the occlusal dentin and the bonding procedures were performed under the irradiation with each light curing unit. The dentin bonding agents used in this study were Scotchbond Multipurpose (3M ESPE), Single Bond (3M ESPE), One-Step (Bisco), Clearfil SE bond (Kuraray), and Adper Prompt (3M ESPE), The shear test was performed by employing the design of a chisel-on-iris supported with a Teflon wall. The fractured dentin surface was observed with SEM to determine the failure mode. The spectral appearance of the LED light curing unit was different from that of the halogen light curing unit in terms of maximum peak and distribution. The LED LCU (maximum peak in 465 nm) shows a narrower spectral distribution than the halogen LCU (maximum peak in 487 nm). With the exception of the Clearfil SE bond (P < 0.05), each 4 dentin bonding agents showed no significant difference between the halogen light-cured group and the LED light-cured group in the mean shear bond strength (P > 0.05). The results can be explained by the strong correlation between the absorption spectrum of camphoroquinone and the narrow emission spectrum of LED.

Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass (박동류 및 비박동류에 의한 체외순환의 비교)

  • Sun, Kyung;Baek, Kwang-Je;Kim, Yo-Han;Kim, Chang-Young;Kim, Kwang-Taek;Kim, Hark-Jei;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

Bovine leukocyte adhesion deficiency

  • Kehrli, Marcus E. Jr.;Park, Yong-ho;Yoo, Han-sang
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.2
    • /
    • pp.247-256
    • /
    • 1999
  • A disease of young Holstein calves characterized by recurrent pneumonia, ulcerative and granulomatous stomatitis, enteritis with bacterial overgrowth, periodontitis, delayed wound healing, persistent neutrophilia and death at an early age had been originally described in 1983 and again in 1987. Most of these calves had stunted growth and a persistent, progressive neutrophilia (often exceeding 100,000/ml). By investigation of pedigrees, all of the affected calves have now been traced to a common sire and confirmed by polymerase chain reaction (PCR) diagnostic DNA testing to be homozygous carriers of a defective allele for bovine CD18. Neutrophils from these calves have several functional deficits and, most importantly, fail to adhere in a ${\beta}_2$-integrin dependent manner. The ${\beta}_2$-integrins represent a family of glycoproteins which participate in various leukocyte adhesion reactions during host defense. The presence or absence of ${\beta}_2$-integrin molecules can be demonstrated on the surface of neutrophils, monocytes and lymphocytes from normal or affected calves using specific monoclonal antibodies and flow cytometry, or by colloidal gold immunolabeling and scanning electron microscopy in backscatter mode. Deficiency of the ${\beta}_2$-integrins on all leukocyte types in Holstein calves is analogous to leukocyte adhesion deficiency (LAD) seen in humans. Neutrophils in bovine (BLAD) and human LAD patients are unable to adhere to the endothelial lining of the cardiovascular system thus interrupting egression of neutrophils into infected tissues. Other leukocytes, while still deficient in expression of the ${\beta}_2$-integrins, are still able to efficiently egress from the blood stream due to interactions of other adhesion molecules that are not as highly expressed on neutrophils. Both BLAD cattle and LAD children (who do not receive bone marrow transplants) often die at an early age as a result of the failure of neutrophils to extravasate into infected tissues. In 1991, Shuster, et $al^{27}$, identified two point mutations within the alleles encoding bovine CD18 in a Holstein calf afflicted with leukocyte adhesion deficiency. One mutation causes an aspartic acid to glycine substitution at amino acid 128 (D128G) in an extracellular region of this adhesion glycoprotein that is highly conserved (> 95% identity) between humans, cattle and mice. The other mutation is silent. Numerous calves with clinical symptoms of leukocyte adhesion deficiency have since been tested and all have been found homozygous for the D128G allele. In addition, calves homozygous far the D128G allele have been identified during widespread DNA testing in the United States. All cattle with the mutant allele are related to one bull, who through artificial insemination (A.I.), sired many calves in the 1950's and 1960's. The carrier frequency of the D128G CD18 allele among U.S. Holstein cattle had reached approximately 15% among active A.I. bulls and 8% among cows. By 1993, the organization of the dairy industry and the diagnostic test developed to genotype cattle, enabled virtually complete eradication of bovine leukocyte adhesion deficiency among current and future A.I. bulls.

  • PDF

SHEAH BOND STRENGTH OF VENEERING CERAMIC TO ELECTROFORMED GOLD WITH THREE DIFFERENT SURFACE TREATMENT (표면처리방법에 따른 전기성형금속의 도재결합강도)

  • Kim Cheol;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.599-610
    • /
    • 2005
  • Purpose: The success of the bonding between electroformed gold and ceramic is dependent on the surface treatment of the pure gold coping. The purpose of this study was to evaluate the bonding strength between the electroformed gold and ceramic with varying surface treatment. Materials and methods: A total of 32 disks,8 were using conventional ceramometal alloy, 24 were using electroforming technique as recommended by manufacturer, were prepared. 24 electroformed disks were divided 3 groups according to surface treatment, i.e. 50 microns aluminium oxide sandblasting(GES-Sand), gold bonder treatment(GES-Bond) and $Rocatec^{TM}$ system(GES-Rocatec). For control group of conventional alloy 50 microns aluminium oxide treatment was done(V-Supragold). Energy dispersive x-ray analysis and scanning electron microscope image were observed. Using universal testing machine, shear bond strength and bonding failure mode at metal-porcelain interface were measured. Results and Conclusion: The following conclusions were drawn: 1. In the energy dispersive x-ray analysis, the Au was main component in electroformed gold(99.9wt%). After surface treatment, a little amount of $Al_2O_3(2.4wt%)$ were found in GES-Sand, and $SiO_2(4wt%)$ in GES-Bond. In GES-Rocatec, however, a large amount of $SiO_2(17.4wt%)$ were found. 2. In the scanning electron microscopy, similar pattern of surface irregu larities were observed in V-Supragold and GES-Sand. In GES-Bond, surface irregularities were increased and globular ceramic particles were observed. In GES-Rocatec, a large amount of silica particles attached to metal surface with increased surface irregularities were observed. 3. The mean shear bond strength values(MPa) in order were $22.9{\pm}3.7(V-Supragold),\;22.1{\pm}3.8(GES-Bond),\;20.1{\pm}2.8(GES-Rocatec)\;and\;13.0{\pm}1.4(GES-Sand)$. There was no significant difference between V-Supragold, GES-Bond, and GES-Rocatec. (P>0.05) 4. Most bonding failures modes were adhesive type in GES-Sand. However, in V-Supragold, GES-Bond and GES-Rocatec, cohesive and combination failures were commonly observed. From the result, with proper surface treatment method electroformed gold may have enough strength compare to conventional ceramometal alloy.

Bending Performance of Glulam Beams Reinforced with Carbon Fiber-Reinforced Plastics Bonded with Polyvinyl Acetate-Based Adhesive (초산비닐수지계 접착제를 사용한 탄소섬유강화플라스틱 복합집성재의 휨 성능)

  • Park, Jun-Chul;Shin, Yoon-Jong;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.364-371
    • /
    • 2009
  • This study was carried out to investigate the bending strength of the Larix glulam beams which were reinforced with CFRP (Carbon fiber reinforced plastic) of which the reinforcement ratios were 0.7% and 2.1% by volume. In the bending test, the rupture shape of the reinforced glulam shows that the reinforced glulam broke firstly in the lowest bottom layer on which tension was loaded, but did not in the upper part reinforced with the CFRP layer. The upper part of the reinforced layer kept strength and did not break when the reinforced glulam broke firstly at the bottom part of the reinforced layer, but broke secondly as loading was increased. In the glulam beams reinforced with CFRP of which the reinforcement ratio was 0.7% by volume, the bending strength of the reinforced beams was increased by 28% at the first break. When beams broke up to the upper part of the reinforced layer, the bending strength of the reinforced beams was increased by 55%, compared to those of control glulam beams. When the glulam beams were reinforced with CFRP of which the reinforcement ratio was 2.1% by volume, the bending strength of the reinforced beams was increased by 77%, compared to those of control glulam beams. The ratio of the height of calculated neutral axis using failure mode recommended by Romani and the height of actual neutral axis using strain gauge was 1.03 and agreed well.

A Study on Creep Effect of Synthetic Fiber Rope Mooring System on Motion Response of Vessel and Tension of Mooring Line (섬유로프 계류시스템의 크리프 효과가 부유체의 운동응답 및 계류선의 장력 변화에 미치는 영향에 관한 연구)

  • Park, Sung Min;Lee, Seung Jae;Kang, Soo Won
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.2
    • /
    • pp.151-160
    • /
    • 2017
  • Growing demand and rapid development of the synthetic fiber rope in mooring system have taken place since it has been used in deep water platform lately. Unlike a chain mooring, synthetic fiber rope composed of lightweight materials such as Polyester(polyethylene terephthalate), HMPE(high modulus polyethylene) and Aramid(aromatic polyamide). Non-linear stiffness and another failure mode are distinct characteristics of synthetic fiber rope when compared to mooring chain. When these ropes are exposed to environmental load for a long time, the length of rope will be increased permanently. This is called 'the creep phenomenon'. Due to the phenomenon, The initial characteristics of mooring systems would be changed because the length and stiffness of the rope have been changed as time goes on. The changed characteristics of fiber rope cause different mooring tension and vessel offset compared to the initial design condition. Commercial mooring analysis software that widely used in industries is unable to take into account this phenomenon automatically. Even though the American Petroleum Institute (API) or other classification rules present some standard or criteria with respect to length and stiffness of a mooring line, simulation guide considers the mechanical properties that is not mentioned in such rules. In this paper, the effect of creep phenomenon in the fiber rope mooring system under specific environment condition is investigated. Desiged mooring system for a Mobile Offshore Drilling Unit(MODU) with HMPE rope which has the highest creep is analyzed in a time domain in order to investigate the effects creep phenomenon to vessel offset and mooring tension. We have developed a new procedure to an analysis of mooring system reflecting the creep phenomenon and it is validated through a time domain simulation using non-linear mooring analysis software, OrcaFlex. The result shows that the creep phenomenon should be considered in analysis procedure because it affects the length and stiffness of synthetic fiber rope in case of high water temperature and permanent mooring system.

Design and Evaluation of a Lung Assist Device for Patients with Acute Respiratory Syndrome using Hollow Fiber Membranes (중공사 막을 이용한 급성호흡곤란증후군 환자용 폐 보조 장치의 설계와 평가)

  • Lee, Sam-Cheol;Kwon, O-Sung;Kim, Ho-Cheol;Hwang, Young-Sil;Lee, Hyun-Cheol
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • The use of the lung assist device (LAD) would be well suited for acute respiratory failure (ARF) patients, combining the simplicity of mechanical ventilation with the ability of extracoporeal membrane oxygenators (ECMO) to provide temporary relief for the natural lungs. This study's specific attention was focused on the effect of membrane vibration in the LAD. Quantitative experimental measurements were performed to evaluate the performance of the device, and to identify membrane vibration dependence on blood hemolysis. We tried to decide upon excited frequency band of limit hemolysis when blood hemolysis came to through a membrane vibration action. The excited frequency of the module type 5, consisted of 675 hollow fiber membranes, showed the maximum gas transfer rate. We concluded that the maximum oxygen transfer rate seemed to be caused by the occurrence of maximum amplitude and the transfer of vibration to hollow fiber membranes. It was excited up to $25{\pm}5$ Hz at each blood flow rate of module type 5. We found that this frequency became the 2nd mode resonance riequency of the flexible in blood flow. Blood hemolysis was low at the excited frequency of $25{\pm}5$ Hz. Therefore, we decided that limit hemolysis frequency of this LAD was $25{\pm}5$ Hz.

Adhesion Performance of Natural Rubber-based Pressure-Sensitive Adhesives for Protecting of Opto-functionalized Sheet (광기능성시트 보호용 천연고무계 점착제의 점착 물성)

  • Park, Young-Jun;Lim, Dong-Hyuk;Kim, Hyun-Joong;Song, Hyun-Suk;Kwon, Hyuk-Jin
    • Journal of Adhesion and Interface
    • /
    • v.8 no.2
    • /
    • pp.15-21
    • /
    • 2007
  • To prepare a natural rubber-based pressure-sensitive adhesive (PSA) for protection film of opto- functionalized sheet, natural rubber (NR) was blended with a DCPD type tackifier and three types of aliphatic hydrocarbon resins, respectively. Also, to supply low cohesion strength of NR, in the fixed ratio of tackifier, synthetic rubber, styrene-isoprene-styrene (SIS) block copolymer was blended with NR as a function of SIS contents. PSA performance of prepared PSAs was evaluated using probe tack and peel strength. Probe tack of NR/tackifier blends was increased with increasing tackifier contents, and showed maximum peak. In addition, probe tack of NR/tackifier blends slightly increased with increasing softening point of aliphatic hydrocarbon resins. Their peel strength increased up to 50 wt% of tackifier contents, but in the over contents of tackifier, they showed stick-slip failure mode. Finally, probe tack of NR/SIS/tackifier blends showed the maximum values at 20~40 wt% of tackifier contents, but at 20 wt% of tackifier contents, they showed fibrillation. For this reason, peel strength showed maximum values at 40 wt% of tackifier contents.

  • PDF

Face Damage Characteristic of Steel Fiber-Reinforced Concrete Panels under High-Velocity Globular Projectile Impact (구형 비상체에 의한 충격하중을 받는 강섬유보강 콘크리트 패널의 손상특성)

  • Jang, Seok-Joon;Son, Seok-Kwon;Kim, Yong-Hwan;Kim, Gyu-Yong;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.411-418
    • /
    • 2015
  • This paper investigates the effects of fiber volume fraction and panel thickness on face damage characteristics of steel fiber-reinforced concrete (SFRC) under high-velocity globular projectile impact. The target specimens were prepared with $200{\times}200mm$ prismatic panels with thickness of 30 or 50 mm. All panels were subjected to the impact of a steel projectile with a diameter of 20 mm and velocity of 350 m/s. Specifically, this paper explores the correlation between mechanical properties and face damage characteristics of SFRC panels with different fiber volume fraction and panel thickness. The mechanical properties of SFRC considered in this study included compressive strength, modulus of rupture, and toughness. Test results indicated that the addition of steel fiber significantly improve the impact resistance of conventional concrete panel. The front face damage of SFRC panels decreased with increasing the compressive toughness and rear face damage decreased as the modulus of rupture and flexural toughness increased. To evaluate the damage response of SFRC panels under high-velocity impact, finite element analysis conducted using ABAQUS/Explicit commercial program. The predicted face damage of SFRC panels based on simulation shows well agreement with the experimental result in similar failure mode.