• Title/Summary/Keyword: Mode of failure

Search Result 2,213, Processing Time 0.027 seconds

The effect of cavity wall property on the shear bond strength test using iris method (Iris 법을 이용한 전단접착강도 측정에서 와동벽의 영향)

  • Kim, Dong-Hwan;Bae, Ji-Hyun;Cho, Byeong-Hoon;Lee, In-Bog;Baek, Seung-Ho;Ryu, Hyun-Mi;Son, Ho-Hyun;Um, Chung-Moon;Kwon, Hyuck-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.170-176
    • /
    • 2004
  • Objectives : In the unique metal iris method. the developing interfacial gap at the cavity floor resulting from the cavity wall property during polymerizing composite resin might affect the nominal shear bond strength values. The aim of this study is to evaluate that the iris method reduces the cohesive failure in the substrates and the cavity wall property effects on the shear bond strength tests using iris method. Materials and Methods : The occlusal dentin of 64 extracted human molars were randomly divided into 4 groups to simulate two different levels of cavity wall property (metal and dentin iris) and two different materials ($ONE-STEP^{\circledR}$ and $ALL-BOND^{\circledR}$ 2) for each wall property. After positioning the iris on the dentin surface. composite resin was packed and light-cured. After 24 hours the shear bond strength was measured at a crosshead speed of 0.5 mm/min. Fracture analysis was performed using a microscope and SEM. The data was analyzed statistically by a two-way ANOV A and t-test. Results : The shear bond strength with metal iris was significant higher than those with dentin iris (p=0.034). Using $ONE-STEP^{\circledR}$, the shear bond strength with metal iris was significant higher than those with dentin iris (p=0.005), but not in $ALL-BOND^{\circledR}$ 2 (p=0.774). The incidence of cohesive failure was very lower than other shear bond strength tests that did not use iris method. Conclusions:The iris method may significantly reduce the cohesive failures in the substrates. According to the bonding agent systems. the shear bond strength was affected by the cavity wall property.

Assessment of System Reliability and Capacity-Rating of Concrete Box-Girder Highway Brdiges (R.C 박스거교의 체계신뢰성 해석 및 안전도 평가)

  • 조효남;신재철
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.187-198
    • /
    • 1995
  • This paper develops practical and reallstic reliabllity models and methods for the evaluation of system rehability and system rellabllity based ratlng of R.C box glrder bridge superstructures. The precise prediction of reberved carrying capacity of bridge as d system is extremely difficult especially when the brldges are highly redundant and slgnlficantly deter 1or;itcd or dainagetl. Thls papel proposes a nt2w approach for the evaluation of reseived system c,drrying capaaty of br~dges in terms ot equ~vdleiit system strength, which may b~ ddcflned as a brtdge system strength correipcmdlng tu the system rehability of the bridge. This cm be ticrAvcd from an Inverse process bami or1 the con~ept of FOSM(F1rst Order Second Moment) form of system reliabihty index. The sf rength llmt state models for K C box girder br~dges suggested In the paper dre based on the basi~ bending and shear strength And thc system reliatxllty pro,~lerri of box gritier super structure 1s formuldted as parallel serles models obtalncd f ~ o m thc FMA(Fdilure blode Rp proath) based on major failure mc>clmusrns or c~itlcal fdure ,>tatcs of each nuder .WOSM(Ad-vanced First Order Second Moment) and IST(1mportance Sampling Technique) simulation algorithm are used for the reliability analysis of the proposed models.

Development of Reliability-Based Design Program based on the MATLAB GUI Environment (MATLAB GUI 환경기반 신뢰성 설계기법의 개발)

  • Jeong, Shin-Taek;Ko, Dong-Hui;Park, Tae-Hun;Kim, Jeong-Dae;Cho, Hong-Yeon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.6
    • /
    • pp.415-422
    • /
    • 2010
  • Development of the reliability-based design program in the GUI environment is inadequate for engineers familiar with the deterministic design to deal with the international design criterion based on the probabilistic design. In this study, the design program based on the GUI environment is developed in order to more efficiently input the design factor and more easily carry out the design works. The GUI environment is the GUIDE (Graphic User Interface Development Environment) tool supported by the latest MATALB version 7.1. In order to test the model reliability, the probabilities of failure (POF) on the breakwater armor block (AB) and gravity quay-wall (QW) in the sliding mode are computed using the model in the Level II and Level III. The POF are 55.4~55.7% for breakwater AB and 0.0006~0.0007% for gravity QW. A non-GUI environment program results of the POF are 55.6% for breakwater AB and 0.0018% for gravity QW. In comparison, the POF difference is negligible for breakwater AB because the exact input design parameters are available, whereas the large POF difference, but within the same order, for gravity QW can be explained by the difference of the input design factors because of the poor input data information.

A Study of Hazard Analysis and Monitoring Concepts of Autonomous Vehicles Based on V2V Communication System at Non-signalized Intersections (비신호 교차로 상황에서 V2V 기반 자율주행차의 위험성 분석 및 모니터링 컨셉 연구)

  • Baek, Yun-soek;Shin, Seong-geun;Ahn, Dae-ryong;Lee, Hyuck-kee;Moon, Byoung-joon;Kim, Sung-sub;Cho, Seong-woo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.222-234
    • /
    • 2020
  • Autonomous vehicles are equipped with a wide rage of sensors such as GPS, RADAR, LIDAR, camera, IMU, etc. and are driven by recognizing and judging various transportation systems at intersections in the city. The accident ratio of the intersection of the autonomous vehicles is 88% of all accidents due to the limitation of prediction and judgment of an area outside the sensing distance. Not only research on non-signalized intersection collision avoidance strategies through V2V and V2I is underway, but also research on safe intersection driving in failure situations is underway, but verification and fragments through simple intersection scenarios Only typical V2V failures are presented. In this paper, we analyzed the architecture of the V2V module, analyzed the causal factors for each V2V module, and defined the failure mode. We presented intersection scenarios for various road conditions and traffic volumes. we used the ISO-26262 Part3 Process and performed HARA (Hazard Analysis and Risk Assessment) to analyze the risk of autonomous vehicle based on the simulation. We presented ASIL, which is the result of risk analysis, proposed a monitoring concept for each component of the V2V module, and presented monitoring coverage.

Fatigue Evaluation of Precast Concrete Deck Connection using Ultra-High Performance, Fiber Reinforced Concrete (초고성능 섬유보강 콘크리트를 적용한 프리캐스트 바닥판 접합부의 피로성능 평가)

  • Lee, Jun-Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.275-285
    • /
    • 2015
  • This experimental study presents the fatigue evaluation of a precast deck connected using Ultra-High Performance, Fiber Reinforced Concrete (UHPFRC). Four types of two identical large-scale specimens were fabricated with simplified splice rebar details which had a short splice length of ten times rebar diameter. The flexural behavior of each type of specimens until failure was investigated and fatigue behavior of the same type of specimens was then evaluated using two-million cyclic loading. In the flexural tests, tensile rebars exhibited the deformation exceeding yielding strain but failure mode related to the splice details was not observed in spite of such a short splice length. In the fatigue tests, damage was not appreciably accumulated by the cyclic loading except initial flexural cracks and the stress variations in tensile rebars was less than the allowable stress range. These experimental results demonstrate that all types of specimens exhibited acceptable fatigue performance and indicate that enhanced mechanical properties of ultra-high performance material permits to use a simplified splice details along with short joint width.

Experimental Study of Down-Scaled Model Slope on the Variation of the Ground Water Level of Drainable Soil Nailing (배수겸용 쏘일네일링의 지하수위 변화에 관한 축소모형사면 실험연구)

  • Kim, Young-Nam;Chae, Young-Su;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.1
    • /
    • pp.39-50
    • /
    • 2013
  • This study aims at investigating the behavior of the ground water level when installing upward soil nails that drain water as well. To do this, a series of down-scaled model tests were conducted. A model slope with weathered soils was prepared and then an artificial rain was scattered on the slope. The relative densities of soil specimen were 60%, 75%, and 90%, and the rainfall intensities 50mm/hr, 75mm/hr, 100mm/hr, and 125mm/hr, respectively. The experimental parameters, such as the ground water level, ratio of soil runoff, and failure mode of the slope were measured and analyzed. As the results, It may be concluded that the ground water level in the slope supported by drainable upward soil nails increases very gradually while the unsupported soil changes dramatically. In addition, the ground water level becomes constant and no failure occurs as time goes by. In case of the relative density of 75%, the runoff ratio seemed to increase up to about 8~15% after reinforcement.

Analysis of Failure Behavior of FRP Rebar Reinforced Concrete Slab based on FRP Reinforced Ratio (FRP 보강근비에 따른 FRP 보강 콘크리트 슬래브의 파괴거동 분석)

  • Jang, Nag-Seop;Kim, Young-Hwan;Oh, Hong-Seob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.173-181
    • /
    • 2021
  • Reinforced concrete structures are exposed to various environments, resulting in reinforcement corrosion due to moisture and ions penetration. Reinforced concrete corrosion causes a decrease in the durability performance of reinforced concrete structures. One solution to mitigate such issues is using FRP rebars, which offer several advantages such as high tensile strength, corrosion resistance, and light-weight than conventional rebars, in reinforced concrete instead of conventional steel rebars. The FRP rebar used should be examined at the limit state because FRP reinforced concrete has linear behavior until its fracture and can generate excessive deflection due to the low elastic modulus. It should be considered while designing FRP reinforced concrete for flexure. In the ultimate limit state, the flexural strength of FRP reinforced concrete as per ACI 440.1R is significantly lower than the flexural strength by applying both the environmental reduction and strength reduction factors accounting for the material uncertainty of FRP rebar. Therefore, in this study, the experimental results were compared with the deflection of the proposed effective moment of inertia referring to the local and international standards. The experimental results of GFRP and BFRP reinforced concrete were compared with the flexural strength as determined by ACI 440.1R and Fib bulletin 40. The flexural strength obtained by the experimental results was more similar to that obtained by Fib bulletin 40 than ACI 440.1R. The flexural strength of ACI 440.1R was conservatively evaluated in the tension-controlled section.

Evaluation of Design Formulae for T-joints on the Branch Plate and Hollow Steel Sections welded connections (지관 플레이트가 주관에 용접된 각형강관 접합부의 설계내력 평가에 관한 연구)

  • Park, Keum Sung;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.581-591
    • /
    • 2005
  • This paper proposes a design formulae that evaluates the design strength of T-joints made of cold-formed square hollow steel sections with longitudinal branch plate. The T-joints had a configuration that a branch member used to longitudinal plate to the main chord in the plane. This study focused on the branch plate T-joints governed by the main chord flange failure mode among the experimental results. Based on the test results of the longitudinal branch plate T-joint in the square hollow sections, the ultimate strength on the T-joints was defined as 1.5 times the load at 1% B the strength of joints that governed the serviceability in control for $16.7{\leq}2\gamma(B/T){\leq}31.3$ and $0.20{\leq}{\beta}(b1/B){\leq}0.75$. Existing yield line models for normal T-joints were investigated to be the main chord flange failure for the branch plate T-joint, and this proposal design formula was based on the theory of the yield line model. Finally, the value of the finite element method compared with the value of the test and theory for the T-joints verified the validity of the design formulae.

EFFECT OF ACID-TREATMENT ON DENTIN BONDING (산 처리가 상아질 접착에 미치는 영향)

  • Kim, Young-Kyong;Kim, Sung-Kyo;Park, Jin-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.73-83
    • /
    • 1993
  • The purpose of this study was to evaluate the effect of various acid treatments on dentin bonding. Freshly extracted human teeth were uprightly embedded in self curing acrylic resin, and their occlusal surfaces were grinded to expose flat dentin surfaces. The specimens were divided into 4 groups. Specimens of one group were not treated so as to be a control and those of the other three groups were threated with 10% polyacrylic acid, 10% phosphoric acid, and 10-3 solution(10% citric acid/3% ferric chloride) respectively. Primer, bonding resin and composite resin were applied over the treated dentin surfaces sequentially. All specimens were stored in $37^{\circ}C$ distilled water for 24 hours, then the tensile bond strength was measured and the treated dentin surfaces and fracured dentin surfaces were examined under a scanning electron microscope. The results were as follows: Bond strengths of acid-treated groups were higher than those of the untreated group. In the acid-treated groups, bond strength was found to be the highest in the 10-3 solution group followed by the 10% phosphoric acid group and the 10% polyacrylic acid group(P<0.01). On SEM examination of dentin surfaces, the untreated dentin surface showed a remaining smear layer and closed dentinal tubules. Dentin surfaces treated with 10 % polyacrylic acid showed a clean dentin surface without the smear layer, but showed remaining smear plugs in dentinal tubules. A dentin surface treated with 10% phosphoric acid or 10-3 solution showed open dentinal tubules without the smear layer or smear plugs. On SEM observation of the fractured dentin-resin interface, the untreated group showed that failure occurred in the smear layer. The group treated with 10% polyacrylic acid showed no resin tag remained in the dentinal tubules, but resin tags in the dentinal tubules were observed in the group treated with the 10% phosphoric acid or the 10-3 solution. On the failure mode examination, the higher the bond strength of the group, the higher the frequency of cohesive failure. The coefficient between bond strength and cohesive failure rate was 0.71.

  • PDF

Structural Integrity Evaluation of Mechanically Fastened FRP Beams Under the Effects of Sustained Loads and Environments (지속하중과 환경영향을 받은 MF-FRP 보강보의 구조건전성 평가)

  • Lee, Jae-Ha;Kim, Woo-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Mechanically fastening FRP (MF-FRP) strips using nails and anchors, has been shown to provide a more ductile behavior to the strengthened structural element than using bonded FRP. To further advance the state of the knowledge on this strengthening method, the current study examined environmental effects for six months on MF-FRP beams. Reinforced concrete beams strengthened with mechanically fastened FRP strips and subjected to sustained loads for six months were exposed to outdoor weather and constant high temperatures ($40^{\circ}C$). For comparison, the behavior of RC beam with and without sustained loads was evaluated. Results from flexural tests did not show any significant degradation or change of failure mode as a result of sustained load and of environmental effects such as high temperatures and outdoor weather over a period of six months. Failure of the beams was governed by FRP delamination followed by concrete crushing as not much load applied to the nail and anchors because of slip effects.