• Title/Summary/Keyword: Mode S

Search Result 6,366, Processing Time 0.039 seconds

Development of lumped model to analyze the hydrological effects landuse change (토지이용 변화에 따른 수문 특성의 변화를 추적하기 위한 Lumped모형의 개발)

  • Son, Ill
    • Journal of the Korean Geographical Society
    • /
    • v.29 no.3
    • /
    • pp.233-252
    • /
    • 1994
  • One of major advantages of Lumped model is its ability to simulate extended flows. A further advantage is that it requires only conventional, readily available hydrological data (rainfall, evaporation and runoff). These two advantages commend the use of this type of model for the analysis of the hydrological effects of landuse change. Experimental Catchment(K11) of Kimakia site in Kenga experienced three phases of landuse change for sixteen and half years. The Institute of Hydrology offered the hydrological data from the catchment for this research. On basis of Blackie's(l972) 9-parameter model, a new model(R1131) was reorganized in consideration of the following aspects to reflect the hydrological characteristics of the catchment: 1) The evapotranspiration necessary for the landuse hydrology, 2) high permeable soils, 3) small catchment, 4) input option for initial soil moisture deficit, and 5) othel modules for water budget analysis. The new model is constructed as a 11-parameter, 3-storage, 1-input option model. Using a number of initial conditions, the model was optimized to the data of three landuse phases. The model efficiencies were 96.78%, 97.20%, 94.62% and the errors of total flow were -1.78%, -3.36%, -5.32%. The bias of the optimized models were tested by several techniques, The extended flows were simulated in the prediction mode using the optimized model and the data set of the whole series of experimental periods. They are used to analyse the change of daily high and low-flow caused by landuse change. The relative water use ratio of the clearing and seedling phase was 60.21%, but that of the next two phases were 81.23% and 83.78% respectively. The annual peak flows of second and third phase at a 1.5-year return period were decreased by 31.3% and 31.2% compared to that of the first phase. The annual peak flow at a 50-year return period in the second phase was an increase of only 4.8%, and that in the third phase was an increase of 12.9%. The annual minimum flow at a 1.5-year return period was decreased by 34.2% in the second phase, and 34.3% in the third phase. The changes in the annual minimum flows were decreased for the larger return periods; a 20.2% decrease in the second phase and 20.9% decrease in the third phase at a 50-year return period. From the results above, two aspects could be concluded. Firstly, the flow regime in Catchment K11 was changed due to the landuse conversion from the clearing and seedling phade to the intermediate stage of pine plantation. But, The flow regime was little affected after the pine trees reached a certain height. Secondly, the effects of the pine plantation on the daily high- and low-flow were reduced with the increase in flood size and the severity of drought.

  • PDF

Chronic Renal Failure in Children: A Nationwide Survey in Korea (소아 만성 신부전증의 전국적인 조사연구)

  • Kim, KyoSun;Jeon, Jeong-Sik;Lee, Ik-Jun;Go, Dae-Gyun;Lee, Gyeong-Il;Yun, Hui-Sang;Gu, Ja-Hun;Go, Cheol-U;Jo, Byeong-Su;Kim, Jun-Sik;Son, Chang-Seong;Yu, Gi-Hwan;An, Yeong-Ho
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.92-101
    • /
    • 2000
  • Purpose : We analyzed the demogaphic data md clinical course of Korean children with chronic renal failure (CRF) observed between 1990 and 1999. Patients and Methods : Questionnaires were mailed to all children's hospitals ail through the country. We asked for primary renal disease age and serum creatinine levels at first presentation with CRF and end-stage renal disease (ESRD), and modes of renal replacement therapy (RRT). Results : 401 children (254 boys, 147 girls) with CRF, defined as a permanent increase of serum creatinine above 1.2 mg/dl for at least 3 months or until death, were identified. This represents an incidence of 3.68 per million child population per year. Of these patients, 22$\%$ on younger than 5 years, 28$\%$ 5 to 10 years and 50$\%$ 10 to 15 year. Eight five $\%$ of the patients could be classified with a primary renal disease. The most frequent cause is glomerulonephritis (36$\%$), followed by chronic pyelonephritis (21$\%$), renal hrpo/dylplasia (9$\%$), and hereditary nephropathies (7$\%$). Reflux nephropathy (16$\%$) was the most common single cause of CRF. ESRD was reached in 70$\%$ of all patient. 99.3$\%$ of these started RRT. Hemodialysis (HD, 42$\%$), peritoneal dialysis (PD, 35$\%$) and transplantation (TP, 23$\%$) were performed as the initial mode of RRT. A total of 161 TPs were performed (159 first grafts, 2 second grafts). A total of 32 patients died. The main causes of death were dialysis related complication in HD patients and infections in PD patients. Survival rate on any form of RRT was 88.7$\%$ during the mean follow-up period of 37 months. Conclusion Major efforts should be directed toward earlier diagnosis and treatment of reflux nephropathy to prevent occurrence of Of. Dialysis and TP have now become well accepted forms of treatment in Korean children with ESRD.

  • PDF

Economic and Political Responses to Globalization: Economic Restructuring and Local Government as an Entrepreneur (세계화에 따른 경제${\cdot}$정치적 동향: 경제재구조와 기업가로서의 지방정부)

  • Koh, Tae-Kyung
    • Journal of the Korean Geographical Society
    • /
    • v.31 no.4
    • /
    • pp.662-671
    • /
    • 1996
  • Since the world's economic and political structures have changed, the term 'globlization' has shown up as a dominant power and as a necessity for regional and national development. Each nation is responding to the globalization process economically and politically in various ways. In general, however, the economic response to the globalization is economic restructuring from the Fordist industries to 'flexible specialization'. And the political response to the globalization is 'global localization' as a new type of local politics(i.e., local policy activism or growth-enhancing local development policies). The crisis of Fordism shifted the role of local governments towards more involovement with local economic development. Local governments are mobilizing for loca economic development, they are taken into a process of institutional change that tends to redefine their responsibilities inside the state. Local governments thus tend to act as an entrepreneur in order to restructure theiir local economies and to compete with other national and international regions. State restructuring towards enerepreneurialism and efficient regional policy pursuing a pro-growth coalition trategy is chosen as a new mode of regulation for the post-Fordism at the local level. The flexible specialization as the post-Fordist economy and the local government as an entrepreneur are the global choice for globalization and a post-Fordist society. The paper focuses on the regulation theory which comprises the political economic perspective on resturcturing. Economic restructuring and state restructuring will be discussed in detail. And the paper tries to combine the economic globalization and the global localization as economic and political responses to globalization.

  • PDF

A STUDY ON THE MODE OF POLYMERIZATION OF LIGHT-CURED RESTORATIVE MATERIALS CURED WITH PLASMA ARC LIGHT CURING UNIT (Plasma arc light curing unit을 이용한 광중합형 수복재의 중합양상)

  • Woo, Youn-Sun;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.262-269
    • /
    • 2002
  • The purpose of this study was to compare the effect of distance of light tip to resin surfaces and exposure time on the polymerization of surface and 2 mm subsurface of composite resins cured with two light sources; conventional halogen light (XL 3000, 3M, U.S.A.) and plasma arc light (Flipo, LOKKI, France) and compare the uniformity of polymerization from the center to the periphery of resin surfaces according to polymerization diameter cure with two light sources. From the experiment, the following results were obtained. 1. Difference of relative light intensity decrease in plasma arc light smaller than that of conventional halogen light(p<0.05). 2. In all groups, microhardness of top surfaces was decreased when distance of the light tip to resin surfaces is more than 2mm and increased according to increase of exposure time(p<0.05). 3. Difference of microhardness of the 2mm subsurface was rapidly decreased when distance of light tip to resin surfaces is more than 4mm(except, plasma arc light exposure time of 3 seconds). and the distance of light tip to resin surfaces and exposure time more affected 2mm subsurface rather than top surface(p<0.05). 4. Although exposure time was increased, difference of microhardness of the 2mm subsurface with the distance of light tip to resin surfaces was relatively high in groups between below 4mm and 6 mm(p<0.05). 5. Plasma arc light exposure time of 6 to 9 seconds produced microhardness values and microhardness change according to various distance similar to those produced with 40 to 80 second exposure to a conventional halogen light(p>0.05). 6. In all groups, microhardness was decreased gradually from the center to the periphery of resin surfaces(p<0.05).

  • PDF

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.

Different Metabolic Patterns of Parkinsonism: Analysed by Statistical Parametric Mapping (통계적 파라미터를 이용한 Parkinsonism의 Metabolic pattern 분석)

  • 주라형;김재승;최보영;문대혁;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.108-123
    • /
    • 2003
  • The purpose of this study is to evaluate the contribution of $^{18}$ F-FDG brain PET in the differentiating Idiopathic parkinson's diesease (IPD), progressive supranuclear palsy (PSP), and multiple system atrophy (MSA). We studied 24 patients with parkinsonism : 8 patients (mean age 67.9$\pm$10.7 y: M/F : 3/5) with IPD, 9 patients (57.9$\pm$9.2 y : M/F : 4/5) with MSA and 7 patients (67.6$\pm$4.8 y : M/F 3/4) with PSP. All patients with parkinsonism and 22 age-matched normal controls underwent $^{18}$ F FDG PET in 3D mode after the injection of 370 MBq $^{118}$ F FDG. The patients with IPD, MSh and PSP were compared with a normal control group by a two-sided t-test of SPM99 (uncorrected P<0.001, extent threshold>100 voxel). All three parkinsonism groups, showed significant hypometabolism in the cerebral neocortex compared to the normal control group. However, the three groups displayed different metabolism in the subcortical structure, brain stem, and cerebellum. In IPD, there was no significant hypometabolism in the putamen, brain stem and cerebellum. However, MSA patients showed significant hypometabolism in the striatum, pons, and cerebellum compared to the normal controls and IPD patients. In addition, PSP showed significant hypometabolism in the caudate nuclei, the thalamus, midbrain, and the cingulate gyrus compared to the normal controls, the IPD, and MSA groups (IPD vs Normal sensitivity/specificity : 75%/l00%, MSA vs Normal sensitivity/specificity :100%/87%, PSP vs Normal sensitivity/specificity : 86%/94%). Our results show that the regional metabolism of IPD, MSA, and PSP is different mainly in the striatum, thalamus, brain stem and cerebellum. An assessment of the $^{18}$ F-FDG PET scan images using SPM may be a useful adjunct to a clinical examination in making a differential diagnosis of Parkinsonism.

  • PDF

MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN (Flowable Composite Resin의 미세변연누출 및 전단결합강도)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

Psychophysiologic Responses to Event Imagery in Traffic Accident Related Patients (교통사고관련 환자에서 사건상상에 대한 정신생리반응)

  • Chung, Sang-Keun;Choi, Myong-Su;Hwang, Ik-Keun
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.1
    • /
    • pp.45-51
    • /
    • 2001
  • Objectives: The experience of traffic accident is a kind of the psychosocial stressors to person. The traffic accident-related patients may show the psychophysiologic hyperarousal. So we examined the differences of psychophysiologic response between patients with and without the memory of experienceing a traffic accident. Methods: Twenty-four traffic accident-related patients were divided into two groups according to ther memory of a traffic accident. In psychological assessment, levels of anxiety and depression were evaluated by State-Trait Anxiety Inventory, Beck's Depression Inventory, and Hamilton Rating Scales For Anxiety and Depression. Heart rate, electrodermal response (EDR), and electromyographic activity (EMG) were measured by biofeedback system, and systolic and diastolic blood pressure by automated vital sign monitor during baseline, task, and rest periods. We utilized script-driven imagery technique as a stressful task. The patients listened to the script describing their own traffic accident experience and were instructed to imagine the event during the task period. Statistically analytic data were obtained from the differences of psychological and psychophysiologic data between two groups. Results: The memory group did not show significantly higher EDR than the none memory group, but showed higher tendency during baseline, imagery, and rest periods. The memory group showed significantly lower EMG than the none memory group during rest period. However, there were no differences in other psychophysiologic reponses between the two groups. Conclusion: Our results showed that the memory group had higher tendency in autonomic arousal level such as electrodermal response than the none memory group. We suggest that physicians need to minimize repetitive imagery of traffic accident (reexperience), and decrease the autonomic hyperarousal in the treatment of traffic accident-related patients.

  • PDF

Development of a deep-learning based tunnel incident detection system on CCTVs (딥러닝 기반 터널 영상유고감지 시스템 개발 연구)

  • Shin, Hyu-Soung;Lee, Kyu-Beom;Yim, Min-Jin;Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.915-936
    • /
    • 2017
  • In this study, current status of Korean hazard mitigation guideline for tunnel operation is summarized. It shows that requirement for CCTV installation has been gradually stricted and needs for tunnel incident detection system in conjunction with the CCTV in tunnels have been highly increased. Despite of this, it is noticed that mathematical algorithm based incident detection system, which are commonly applied in current tunnel operation, show very low detectable rates by less than 50%. The putative major reasons seem to be (1) very weak intensity of illumination (2) dust in tunnel (3) low installation height of CCTV to about 3.5 m, etc. Therefore, an attempt in this study is made to develop an deep-learning based tunnel incident detection system, which is relatively insensitive to very poor visibility conditions. Its theoretical background is given and validating investigation are undertaken focused on the moving vehicles and person out of vehicle in tunnel, which are the official major objects to be detected. Two scenarios are set up: (1) training and prediction in the same tunnel (2) training in a tunnel and prediction in the other tunnel. From the both cases, targeted object detection in prediction mode are achieved to detectable rate to higher than 80% in case of similar time period between training and prediction but it shows a bit low detectable rate to 40% when the prediction times are far from the training time without further training taking place. However, it is believed that the AI based system would be enhanced in its predictability automatically as further training are followed with accumulated CCTV BigData without any revision or calibration of the incident detection system.

Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error (유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석)

  • Sohn Jason W.;Mansur David B.;Monroe James I.;Drzymala Robert E.;Jin Ho-Sang;Suh Tae-Suk;Dempsey James F.;Klein Eric E.
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Automated analysis software was developed to measure the magnitude of the intrafractional and interfractional errors during breast radiation treatments. Error analysis results are important for determining suitable planning target volumes (PTV) prior to Implementing breast-conserving 3-D conformal radiation treatment (CRT). The electrical portal imaging device (EPID) used for this study was a Portal Vision LC250 liquid-filled ionization detector (fast frame-averaging mode, 1.4 frames per second, 256X256 pixels). Twelve patients were imaged for a minimum of 7 treatment days. During each treatment day, an average of 8 to 9 images per field were acquired (dose rate of 400 MU/minute). We developed automated image analysis software to quantitatively analyze 2,931 images (encompassing 720 measurements). Standard deviations ($\sigma$) of intrafractional (breathing motion) and intefractional (setup uncertainty) errors were calculated. The PTV margin to include the clinical target volume (CTV) with 95% confidence level was calculated as $2\;(1.96\;{\sigma})$. To compensate for intra-fractional error (mainly due to breathing motion) the required PTV margin ranged from 2 mm to 4 mm. However, PTV margins compensating for intefractional error ranged from 7 mm to 31 mm. The total average error observed for 12 patients was 17 mm. The intefractional setup error ranged from 2 to 15 times larger than intrafractional errors associated with breathing motion. Prior to 3-D conformal radiation treatment or IMRT breast treatment, the magnitude of setup errors must be measured and properly incorporated into the PTV. To reduce large PTVs for breast IMRT or 3-D CRT, an image-guided system would be extremely valuable, if not required. EPID systems should incorporate automated analysis software as described in this report to process and take advantage of the large numbers of EPID images available for error analysis which will help Individual clinics arrive at an appropriate PTV for their practice. Such systems can also provide valuable patient monitoring information with minimal effort.

  • PDF