• Title/Summary/Keyword: Mode B

Search Result 2,440, Processing Time 0.034 seconds

X-RAY ASTRONOMY EXPERIMENT ON THE INDIAN SATELLITE IRS-P3

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;SHAH M. R.;MCKERJEE K.;VARIA M. N.;YADAV J. S.;DEDHIA D. K.;MALKAR J. P.;SHAH P.;DAMLE S. V.;MARAR T. M. K.;SEETHA S.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.429-432
    • /
    • 1996
  • An x-ray astronomy experiment consisting of three collimated proportional counters and an X-ray Sky Monitor (XSM) was flown aboard the Indian Satellite IRS-P3 launched on March 21, 1996 from SHAR range in India. The Satellite is in a circular orbit of 830 km altitude with an orbital inclination of $98^{\circ}$ and has three axis stabilized pointing capability. Each pointed-mode Proportional Counter (PPC) is a multilayer, multianode unit filled with P-10 gas ($90\%$ Ar + $10\%\;CH_4$) at 800 torr and having an aluminized mylar window of 25 micron thickness. The three PPCs are identical and have a field of view of $2^{\circ}{\times}2^{\circ}$ defined by silver coated aluminium honeycomb collimators. The total effective area of the three PPCs is about 1200 $cm^2$. The PPCs are sensitive in 2-20 keV band. The XSM consists of a pin-hole of 1 $cm^2$ area placed 16 cm above the anode plane of a 32 cm$\times$32 cm position sensitive proportional counter sensitive in 3-8 keV interval. The position of the x-ray events is determined by charge division technique using nichrome wires as anodes. The principal objective of this experiment is to carry out timing studies of x-ray pulsars, x-ray binaries and other rapidly varying x-ray sources. The XSM will be used to detect transient x-ray sources and monitor intensity of bright x-ray binaries. Observations of black-hole binary Cyg X-1 and few other binary sources were carried out in early May and July-August 1996 period. Details of the x-ray detector characteristics are presented and preliminary results from the observations are discussed.

  • PDF

The biblographical study on $T{\acute{o}}u\;f{\bar{e}}ng$ and Migraine -(Comparative study between Oriental and Western Medicine)- (두풍(頭風)과 편두통(Migraine)에 대(對)한 동서의학적(東西醫學的) 문헌고찰(文獻考察))

  • Oh, So-Jeo;Jeong, Ji-Cheon;Lee, Won-Chul
    • The Journal of Internal Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.129-138
    • /
    • 1993
  • This report on the $T{\acute{o}}u\;f{\bar{e}}ng$ and Migraine comes to conclude, through the study of the Oriental- Western medical references, as follow; 1. First, $T{\acute{o}}u\;f{\bar{e}}ng$ and Migraine had some concurrencies that both the two symptoms have appeared severe and recurrent headache and more often to the female. 2 Many of them e.g. Sensory disturbance, Vertigo, Nausea, Vomiting, Tinnitus etc. in the prodrome and main symptom of $T{\acute{o}}u\;f{\bar{e}}ng$ and Migraine were identical, especially the symptom of the $f{\bar{e}}ng\;t{\acute{a}}n\;t{\acute{o}}u\;t{\grave{o}}ng$ was similar to the prodrome of the Migraine. We could find out the semilarity of the symptoms through that Migraine is proximately set in unilateral, and $Pi{\bar{a}}nT{\acute{o}}u\;f{\bar{e}}ng$ is so called alias $B{\grave{a}}n\;bi{\bar{a}}n\;t{\acute{o}}u\;t{\grave{o}}ng$. 3. The pathogeny of $T{\acute{o}}u\;f{\bar{e}}ng$ include the case of ‘$f{\bar{e}}ng\;xi{\acute{e}}\;r{\grave{u}}\;n{\bar{a}}o$’, the patient feeling weak condition, $T{\acute{a}}n,\;T{\acute{a}}nshi,\;T{\acute{a}}nhu{\breve{o}},\;Y{\grave{u}}q{\grave{i}}$, etc. and, ‘$t{\acute{a}}n\;zhu{\grave{o}}\;sh{\grave{a}}ng\;y{\acute{a}}o$’, ‘$G{\bar{a}}n\;y{\acute{a}}ng\;hu{\grave{a}}\;f{\bar{e}}ng$’. There were variable that $F{\bar{e}}ng,\;Xu{\grave{e}},\;F{\bar{e}}ngr{\grave{a}},\;F{\bar{e}}ngx{\bar{u}},\;Xu{\grave{e}}x{\bar{u}},\;Hu{\check{o}}$ in the left, and $t{\acute{a}}n,\;R{\grave{e}},\;t{\acute{a}}nr{\grave{e}},\;Qir{\acute{a}}$ in the right partial pathogeny. It was referred $Sh{\grave{a}}o\;y{\acute{a}}ng\;j{\bar{i}}ng$, $Ju{\acute{e}}\;y{\bar{i}}n\;j{\bar{i}}ng$, $Y{\acute{a}}ng\;m{\acute{i}}ng\;j{\bar{i}}ng$, $T{\grave{a}}i\;y{\acute{a}}ng\;j{\bar{i}}ng$ in connection with the Meridian system. And otherwise the primary cause of Migraine is still unknown to us. Heredity is probably important, but the mode of transmission is uncertain. Recently, the important assumption is the vasomotor change caused by vasoconstrictors like that norepinephrine, epinephrine, and serotonin etc.

  • PDF

Association of Blood Pressure Levels with Carotid Intima-Media Thickness and Plaques (혈압 수준과 경동맥 내중막 두께 및 동맥경화반의 관련성)

  • Lee, Young-Hoon;Kweon, Sun-Seog;Choi, Jin-Su;Rhee, Jung-Ae;Choi, Sung-Woo;Ryu, So-Yeon;Shin, Min-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.5
    • /
    • pp.298-304
    • /
    • 2009
  • Objectives : The aim of this study was to investigate the association of blood pressure levels with the common carotid artery intima-media thickness (CCA-IMT) and carotid plaques. Methods : Data were obtained from 2,635 subjects, aged 50 years and over, who participated in the Community Health Survey (a population-based, cross-sectional study) in Dong-gu, Gwangju city between 2007 and 2008. Participants were categorized into three groups according to blood pressure levels; normotensives (<120/80 mmHg), prehypertensives (120-139/80-89 mmHg), and hypertensives ($\geq$140/90 mmHg). Prehypertensives were further categorized as low prehypertensives (120-129/80-84 mmHg) and high prehypertensives (130-139/85-89 mmHg). Carotid intima-media thickness and plaques were evaluated with a high-resolution B-mode ultrasound. Statistical analyses were performed using chi-square test, ANOVA, and multiple logistic regression. Results : Prehypertensives had significantly greater maximal CCA-IMT values than normotensives, with a multivariate adjusted odds ratio of 1.78 (95% CI=1.36-2.32) for abnormal CCA-IMT (maximal CCA-IMT$\geq$1.0 mm), and 1.45 (95% CI=1.19-1.77) for carotid plaques. The multivariate adjusted odds ratio of low prehypertensives was 1.64 (95% CI=1.21-2.21) for abnormal CCA-IMT, and 1.30 (95% CI=1.04-1.63) for carotid plaques compared with normotensives. Subject with hypertension had higher frequency of abnormal CCA-IMT (odds ratio, 2.18; 95% CI=1.49-3.18), and carotid plaques (odds ratio, 1.98; 95% CI=1.46-2.67) compared with normotensives after adjustment for other cardiovascular risk factors. Conclusions : Our results indicate that there is a significant increase in the prevalence of carotid atherosclerosis in subjects with prehypertension (even in low prehypertensives) compared with normotensive subjects. Further studies are required to confirm the benefits and role of carotid ultrasonography in persons with prehypertension.

The use of SMA wire dampers to enhance the seismic performance of two historical Islamic minarets

  • El-Attar, Adel;Saleh, Ahmed;El-Habbal, Islam;Zaghw, Abdel Hamid;Osman, Ashraf
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.221-232
    • /
    • 2008
  • This paper represents the final results of a research program sponsored by the European Commission through project WIND-CHIME ($\underline{W}$ide Range Non-$\underline{IN}$trusive $\underline{D}$evices toward $\underline{C}$onservation of $\underline{HI}$storical Monuments in the $\underline{ME}$diterranean Area), in which the possibility of using advanced seismic protection technologies to preserve historical monuments in the Mediterranean area is investigated. In the current research, the dynamic characteristics of two outstanding Mamluk-Style minarets, which similar minarets were reported to experience extensive damage during Dahshur 1992 earthquake, are investigated. The first minaret is the Qusun minaret (1337 A.D, 736 Hijri Date (H.D)) located in El-Suyuti cemetery on the southern side of the Salah El-Din citadel. The minaret is currently separated from the surrounding building and is directly resting on the ground (no vaults underneath). The total height of the minaret is 40.28 meters with a base rectangular shaft of about 5.42 ${\times}$ 5.20 m. The second minaret is the southern minaret of Al-Sultaniya (1340 A.D, 739 H.D). It is located about 30.0 meters from Qusun minaret, and it is now standing alone but it seems that it used to be attached to a huge unidentified structure. The style of the minaret and its size attribute it to the first half of the fourteenth century. The minaret total height is 36.69 meters and has a 4.48 ${\times}$ 4.48 m rectangular base. Field investigations were conducted to obtain: (a) geometrical description of the minarets, (b) material properties of the minarets' stones, and (c) soil conditions at the minarets' location. Ambient vibration tests were performed to determine the modal parameters of the minarets such as natural frequencies and mode shapes. A $1/16^{th}$ scale model of Qusun minaret was constructed at Cairo University Concrete Research Laboratory and tested under free vibration with and without SMA wire dampers. The contribution of SMA wire dampers to the structural damping coefficient was evaluated under different vertical loads and vibration amplitudes. Experimental results were used along with the field investigation data to develop a realistic 3-D finite element model that can be used for seismic risk evaluation of the minarets. Examining the updated finite element models under different seismic excitations indicated the vulnerability of such structures to earthquakes with medium to high a/v ratio. The use of SMA wire dampers was found feasible for reducing the seismic risk for this type of structures.

Interpretations of Staurolite Porphyroblast and Pseudomorph Formed During Polymetamorphism Using THERMOCALC (THERMOCALC를 이용한 다변성작용 동안 성장한 십자석 반상변정과 가상의 해석)

  • Kim Hyeong-Soo
    • The Journal of the Petrological Society of Korea
    • /
    • v.15 no.1 s.43
    • /
    • pp.10-24
    • /
    • 2006
  • Staurolite grains in staurolite, kyanite and sillimanite zones occurred in the Littleton Formation, Northcentral Massachusetts have interpreted to form by Barrovian-type metamorphism during Acadian orogeny. However, various occurrence of staurolite in the three zones, (a) porphyroblast, (b) randomly oriented and coarse-grained muscovite pseudomorph after staurolite, (c) recrystallized staurolite at the margin of garnet porphyroblast and within the pseudomorph, indicates that they have resulted from polymetamorphism. Staurolite in these three metamorphic zones can be formed by demise of chlorite or chloritoid that depends on difference of bulk-rock compositions and changes of P-T conditions. Staurolite modal proportion calculated in MnNCKFHASH system using THERMOCALC program reveals that staurolite could have grown with garnet with increasing pressure and temperature, if it coexist with chlorite. After demise of chlorite and appearance of biotite, staurolite mode decrease with increasing pressure and temperature. Therefore, based on the previous P-T paths for the Acadian metamorhism, staurolite porphyroblast grew with garnet during 400-370 Ma. Randomly oriented and coarse-grained muscovite pseudomorphs after staurolite probably have grown due to heating with appearance of kyanite and sillimanite. Consequently, pseudomorphisrn of staurolite occurred by heating derived from locally intense Alleghanian shearing (ca. 320-300 Ma) overprinted the Acadian metamorphism. Recrystallized fine-grained staurolite in sillimanite zone observed between the grain boundaries of muscovite in the pseudomorphs and at the edge of garnet porphyrobasts has formed during decreasing temperature and pressure (ca. 300-280 Ma) after peak temperature (ca. $700^{\circ}C$) of the Allegllanian metamorphism.

Use of ultrasonography for improving reproductive efficiency in cows II. Comparative evaluation of ovarian structures using ultrasonography and plasma progesterone analysis in subestrous dairy cows (초음파 진단장치를 이용한 축우의 번식효율증진에 관한 연구 II. 무발정 젖소에서 초음파검사 및 progesterone 농도측정에 의한 난소 구조물의 비교평가)

  • Son, Chang-ho;Kang, Byong-kyu;Choi, Han-sun;Kang, Hyun-gu;Paik, In-seok;Suh, Guk-hyun
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.642-651
    • /
    • 1998
  • The accuracy of ultrasonography for determining the presence of a functional corpus luteum in subestrous dairy cows was investigated, using a radioimmunoassay for progesterone in plasma. Luteal status (high or low progesterone concentrations) was diagnosed in 534 cows, using B-mode transrectal ultrasonography. Accuracy of ultrasonography was 96.3% and 88.8% in the cows with and without functional corpus luteum, respectively. In 362 cows diagnosed with functional corpus luteum by ultrasonographic examination, 20 cows were diagnosed with the non-functional corpus luteum by analysis of plasma progesterone concentrations (false positive). In 172 cows with non-functional corpus luteum by ultrasonographic examination, 13 cows were diagnosed with the functional corpus luteum based on plasma progesterone assay (false negative). Most of the corpus luteum with well-defined border and homogeneous echotexture were diagnosed with functional corpus luteum. All cows that were not detected a corpus luteum by ultrasonographic examination were diagnosed as non-functional corpus luteum. The corpus luteum of cows that were diagnosed with false positive appeared homogeneous echotexture and above 15 mm in diameter, but the corpus luteum was the non-functional corpus luteum within Day 5 (Day 0 is ovulation day) or after Day 19. The corpus luteum of cows that were diagnosed with false negative appeared heterogeneous echogenicity and below 15 mm in diameter, but the corpus luteum was the functional corpus luteum after Day 5 or around Day 17. It was concluded that accuracy of ultrasonography was excellent for determining the presence of a functional corpus luteum in subestrous dairy cows. The corpus luteum that was diagnosed with false positive or false negative was the developing or regressing states. Thus, ultrasonography was required a serial examination of two or three times accurately diagnosing these corpus luteum.

  • PDF

Ciphering Scheme and Hardware Implementation for MPEG-based Image/Video Security (DCT-기반 영상/비디오 보안을 위한 암호화 기법 및 하드웨어 구현)

  • Park Sung-Ho;Choi Hyun-Jun;Seo Young-Ho;Kim Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.27-36
    • /
    • 2005
  • This thesis proposed an effective encryption method for the DCT-based image/video contents and made it possible to operate in a high speed by implementing it as an optimized hardware. By considering the increase in the amount of the calculation in the image/video compression, reconstruction and encryption, an partial encryption was performed, in which only the important information (DC and DPCM coefficients) were selected as the data to be encrypted. As the result, the encryption cost decreased when all the original image was encrypted. As the encryption algorithm one of the multi-mode AES, DES, or SEED can be used. The proposed encryption method was implemented in software to be experimented with TM-5 for about 1,000 test images. From the result, it was verified that to induce the original image from the encrypted one is not possible. At that situation, the decrease in compression ratio was only $1.6\%$. The hardware encryption system implemented in Verilog-HDL was synthesized to find the gate-level circuit in the SynopsysTM design compiler with the Hynix $0.25{\mu}m$ CMOS Phantom-cell library. Timing simulation was performed by Verilog-XL from CadenceTM, which resulted in the stable operation in the frequency above 100MHz. Accordingly, the proposed encryption method and the implemented hardware are expected to be effectively used as a good solution for the end-to-end security which is considered as one of the important problems.

Clinical Value of Real Time Elastography in Patients with Unexplained Cervical Lymphadenopathy: Quantitative Evaluation

  • Fu, Ying;Shi, Yun-Fei;Yan, Kun;Wang, Yan-Jie;Yang, Wei;Feng, Guo-Shuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5487-5492
    • /
    • 2014
  • Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 to February 2012, 39 enlarged lymph nodes from 39 patients with unexplained cervical lymphadenopathy were assessed. All the patients were examined by both B-mode ultrasound, color Doppler flow imaging and elastography. The method of analyzing elasto-graphic data was the calculation of the 10 parametres ("mean", "sd", "area%", "com", "kur", "ske", "con", "ent", "idm", "asm") offered by the software integrated into the Hitachi system. The findings were then correlated with the definitive tissue diagnosis obtained by lymph node dissection or biopsy. Final histology revealed 10 cases of metastatic lymph nodes, 11 cases of lymphoma, 12 cases of tuberculosis and 6 cases of nonspecific lymphadenitis. The significant distinguishing features for conventional ultrasound were the maximum short diameter (p=0.007) and absent of echogenic hilum (p=0.0293). The diagnostic accuracy was 43.6% (17/39 cases) and there were 17 patients with equivocal diagnosis. For elastography, "mean" (p=0.003), "area%" (p=0.009), "kurt" (p=0.0291), "skew" (p=0.014) and "cont" (p=0.012) demonstrated significant differences between groups. With 9 of the 17 patients with previous equivocal diagnoses (52.9%) definite and correct diagnoses could be obtained. The diagnostic accuracy for conventional ultrasound combined elastography was 69.2% (27/39 cases). There were differences in the diagnostic sensitivity of the two methods (p=0.0224). Ultrasound combined with elastography demonstrated higher rates of conclusive and accurate diagnoses in patients with unexplained cervical lymphadenopathy than conventional ultrasound. The quantitative program showed good correlation with the pathology of different lymph node diseases.

An Admission Control Mechanism to guarantee QoS of Streaming Service in WLAN (WLAN에서 스트리밍 서비스의 QoS를 보장하기 위한 승인 제어 기술)

  • Kang, Seok-Won;Lee, Hyun-Jin;Lee, Kyu-Hwan;Kim, Jae-Hyun;Roh, Byeong-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.595-604
    • /
    • 2009
  • The HCCA reserves the channel resources based on the mean data rate in IEEE 802.11e. It may cause either the waste of channel resource or the increase of transmission delay at MAC layer if the frame size is rapidly varied when a compressed mode video codec such as MPEG video is used. To solve these problems, it is developed that the packet scheduler allocates the wireless resource adaptation by according to the packet size. However, it is difficult to perform the admission control because of the difficulty with calculating the available resources. In this paper, we propose a CAC mechanism to solve the problem that may not satisfy the QoS by increasing traffic load in case of using EDCA. Especially, the proposed CAC mechanism calculates the EB of TSs using the traffic information transmitted by the application layer and the number of average transmission according to the wireless channel environment, and then determines the admission of the TS based on the EB. According to the simulation results of the proposed CAC mechanism, it admitted the TSs under the loads which are satisfied within the delay bound. Therefore, the proposed mechanism guarantees QoS of streaming services effectively.

Development of Differential Diagnosis and Treatment Method of Reproductive Disorders Using Ultrasonography in Cows II. Differential Diagnosis of Subestrous Dairy Cows (초음파검사에 의한 소의 번식장애 감별진단 및 치료법 개발 II. 무발정우의 감별진단)

  • 강병규;최한선;강현구;오기석;서동호;손창호;서국현
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.307-318
    • /
    • 1998
  • Accuracy of rectal palpation and ultrasonography for differential diagnosis of subestrous dairy trows were investigatedl using the result of pIRsma progesterone assay. The ovaries were examined 2 times of 10 days interval in 520 posearom and postinsemination subestroHs dairy cows, using rectal palpation and B-mode transrectal ultrasonography. The results of rectal palpation, ultrasonographic examination and measurement of plasma progesterone profiles in 520 subestrous dairy cows were silent brat or error of estrus detection 303 (58.3%), persistent corpus luteum 59 (11.3%), follicular cyst 37 (7.1%), luteal cyst 16 (3.1%), inactive ovary 9 (1.7%), granulosa tumor 1 (0.2%), hydmsalphinx 1 (0.2%), endomehris 81 (15.6%), pyometra 12 (2.3%) and mummified fetus 1 (0.2%), respectively. Accuncy of rectal palpation and ultrasonography for diagiosing ovarian disordeir based on plasma progesterone profiles were silent heat or error of estrus detection 80.5% and 96.7%$\boxUl$ persistent corpus luteum 57.6% and 94.9%, follicular cyst 62.5% and 91.9%1 luteal cyst 62.5% and 87.5%, maclive ovary 55.6% and 88.9% and granulosa cell tumor 100% and 100%, respectively. Acnuucy of rectal palpation for diagnosing uterine disorders based on ultrasonography was pyometra 75.0%1 endometritis 51.9% and mummified fetus 100%, respectively. Cbaracteristic ultrasonographic appearances of ovaries in subestrous dairy cows were as follows; Silent heat or error of estrus detection: anechoic follicle or hypoechoic corpus luteum than ovarian stroma was alternately present on Day 0 (first examination) and Day 10. Follicular cyst: uniformly nonechogenic ovarian structure $\geq $ 25 mm in diameter with a wall < 3 mm was present in ipsilateral on Day 0 and Day 10. Luteal cyst: luteal cyst was similar to follicular cysts but thickness of cystic wall was $\geq $ 3 mm. Inactive ovary : structures within ovaries was not present on Day 0 Bnd Day 10. Characteristic uthssonograpsc appearances of uterus in subestrous dairy cows were as follows; Endometritis: characterized by uterine lumen containing fluid in which 'snowy'echogenic particles art suspended. Pyometra: ultrasonographic appearance of pyometra was diffuse echogenic particles distributed in fluid within the distended uterus, and a thickened uterine wall. These results indicated that ultrasonography was practical far diagnosing reproductive disorders. To diagnosing ovarian disorders, ultrasonography should be carried out 2 times of 10 days interval and rndometritis should be differentiated with uterus of luteal phase in normal cycling cows.

  • PDF