Jeon, Joo Hyeon;Lee, Na Eun;Lee, Yoon Ho;Jang, Jea Moon;Joo, Moon Gab;Yoo, Byung Hwa;Yu, Jae Do
Journal of Information Processing Systems
/
v.17
no.6
/
pp.1179-1190
/
2021
A data acquisition and monitoring system was developed for an automated system of a smart fish farm. The fish farm is located in Jang Hang, South Korea, and was designed as circulation filtration system. Information of every aquaculture pool was automatically measured by pH sensors, dissolved oxygen sensors, and water temperature sensors and the data were stored in the database in a remoted server. Modbus protocol was used for gathering the data which were further used to optimize the pool water quality to predict the rate of growth and death of fish, and to deliver food automatically as planned by the fish farmer. By using JSON protocol, the collected data was delivered to the user's PC and mobile phone for analysis and easy monitoring. The developed monitoring system allowed the fish farmers to improve fish productivity and maximize profits.
국내 산업현장에서 공장시스템들을 효율적이고 유기적으로 연결시키기 위해서 산업네트워크인 산업용 프로토콜을 활용한다. 그중에서도 국내 굴지의 석유화학 공정에서는 Modbus Protocol을 사용하고 있다. 하지만 이에 대한 연구가 국내에서는 매우 열악하여 제대로 된 정보를 찾기 힘들다. 이에 국내 산업환경에서 활용하는 모드버스 프로토콜을 개선하여 이를 현장에 적용하는 연구를 하게되었다. 이전 연구에서는 모드버스 프로토콜 개선을 위해서 캐쉬 기법을 적용하여 탱크 데이터 처리 시간을 단축시키는 결과를 도출하였으며 이를 이용하여 석유화학 공정 탱크의 교체시기를 판별하였다. 이번에는 모드버스 캐쉬 기법을 이용하여 탱크사용 예측과 하드닝 기법을 적용한 탱크 테이터예측 알고리즘을 설계하고 이를 시뮬레이션 결과를 소개하고자 한다.
The vacuum gauge control system has been designed and implemented using multi-serial communication controllers (MSCC) for the 2.5 Gev storage ring at the Pohang Accelerator Laboratory (PAL). There are 20 Balzers vacuum gauges and 17 Granville-Phillips vacuum gauges at the storage ring. A MSCC have two RS485 (max speed 460.8Kbps) field network port, 8 channel serial communication ports (max speed 460.8Kbps) connected to gauge controller for serial communication control. 12 MSCCs are connected to a personal computer (PC) through the RS485 field network. The PC can automatically control the MSCCs by sending set of commands through the network. The commands specify the duration of the MODBUS protocol. Upon receiving a command from a PC running under Windows2000 through the network, the MSCC communicate through the serial output ports to gauge controller. In this paper, we describe control structure and scheme of the vacuum gauge control system.
Proceedings of the Korean Society of Marine Engineers Conference
/
2001.05a
/
pp.192-196
/
2001
These days, most of electric power facilities need high stability. Therefore integrated system has been required to monitor and control electronic power distribution system in fields at all times when the interruption of electric power has occurred. To construct this system, unit that convert and process the input signal from fields needed. And for control and monitoring from remote place MMI software is required. Lastly network equipments are required for real-time communications. So, in this paper, units for control and monitoring of emergency power generator and for electric power monitoring in normal electric power and interruption of electric power are developed. Also integrated remote system for monitoring in remote is developed.
Journal of Institute of Control, Robotics and Systems
/
v.9
no.4
/
pp.340-346
/
2003
Driven by the growth of the Internet and the increasing ubiquity of embedded computing systems, the embedded system is exploding in terms of it proliferation of products and the number of complex applications. Intelligent dedicated systems and appliances used in interface, monitoring, communications, and control applications increasingly demand the services of a sophisticated, state-of-the-art operating system. In the case of industrial controller, it is required to use a real-time operating system (RTOS) as a good building block to enable Internet connectivity. However, commercial RTOSes are increasingly less desirable due to their lack of standardization and their inability to keep pace with the rapid evolution of technology. In order to overcome these problems, we consider using embedded Linux and embedded web server. Availability of source code, reduced licensing, reliability, open source community support, as well as others, are key reasons for the use of embedded linux by embedded developers. In this paper, we develop embedded linux platform to control the industrial inverter with the Internet connecting feature. The method of web-based management is also proposed by using the embedded web server and Java applet. We show the feasibility of remote management for the commercial inverter controller with the proposed three-tier web-based remote management system.
A PMS (Power Management System) controls vessel's power systems to improve the system efficiency and to protect a blackout condition. The PMS should be developed with considering the type and the capacity of the vessel's power system. It is necessary to test the PMS functions developed for vessel's safe operations under various sailing situations. Therefore, the function tests in cooperation with practical power systems are required in the PMS development. In this paper, a hardware-in-the-loop (HIL) simulator is developed for the purposes of the PMS function tests. The HIL simulator can be more cost-effective, more time-saved, easier to reproduce, and safer beyond the normal operating range than conventional off-line simulators, especially at early stages in development processes or during fault tests. Vessel's power system model is developed by using a MATLAB/SIMULINK software and by communicating between an OPAL-RT's OP5600 simulator. The PMS uses a Modbus communication protocol implemented using LabVIEW software. Representative tests of the PMS functions are performed to verify the validity of the proposed HIL-based test platform.
The Transactions of The Korean Institute of Electrical Engineers
/
v.67
no.10
/
pp.1382-1387
/
2018
There is a high demand for energy efficiency improvement of factories that make up a large part of national electric energy. Therefore, research on smart FEMS technology for monitoring, analyzing and controlling energy consumption patterns is under way, but there is still a lack of research on detailed element technology for communication and control inside the factory. In this paper, we proposed OFDM VLC system based on MODBUS protocol for communication between gateways, sensors, and devices to implement smart FEMS in indoor factory environment. Assuming a conveyor belt load control, we validated the proposed system by simulating the inverter motor control and checking the performance.
광섬유 온도센서를 이용하여 밀폐형 폐쇄배전반 내부에 설치된 진공차단기(Vacuum Circuit Breaker: 이하 VCB)의 접촉부 및 부싱부 이상 온도변화를 상시 감시할 수 있는 On-line 온도 감시 시스템을 개발하였다. 본 시스템은 온도변화를 측정하는 광센서부, 광신호의 이동 통로역할을 하는 Optical Head부, 변환된 전기신호를 신호처리하고 상위 시스템으로 통신을 수행할 신호처리장치의 세 부분으로 구성되어 있다. 구현한 시스템은 측정 범위가 $-25\;{\sim}\;200^{\circ}C$인 희토류 원소가 첨가된 광섬유 온도센서를 사용하였고, 시스템의 측정 범위는 $-20\;{\sim}\;150^{\circ}C$, 측정 정밀도는 Full Scale의 ${\pm}2\;%$, 측정 주파수는 0.1 Hz이었다. 검출된 온도 값은 Modbus Protocol을 이용하여 상위 시스템으로 송신하도록 구현하였다.
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
2021.05a
/
pp.283-284
/
2021
The domestic and overseas IoT (Internet of Things)-based automation industry is developing remarkably, and the development of this automation technology is further accelerated by the development of sensor technology. In recent years, the smart farm industry for the purpose of growing crops based on various sensor technologies is rapidly developing. In the case of smart farms, real-time monitoring and mobile services are provided by measuring representative environmental data such as temperature, humidity, and CO2 required for crop cultivation. Most of these environmental monitoring and control operations use the RS-485-based Modbus (RTU) communication method. In this paper, we intend to test the performance of sensor data and actuator information required for smart farm construction by building a platform for controlling sensor data and actuators based on LabView using MQTT (Message Queuing Telemetry Transport), an IoT standard protocol.
Kim, Yunha;Yu, Chool;Oh, Eun;Kim, Chanmoon;Park, Ikdong;Kim, Yongseong;Choi, Hyunju
Journal of Korean Society of Water and Wastewater
/
v.33
no.5
/
pp.329-339
/
2019
Recently, the advancement of information and communication technology(ICT) is expanding the connectivity through Internet of Things(IoT), and the media of connection is also expanding from wire/cable transmission to broadband wireless communication, which has significantly improved mobility. This hyperconnectivity has become a key element of the fourth industrial revolution, whereas the supervisory control network of purification plants in korea is operated as a communication network separated from the outside, thereby lagging in terms of connectivity. This is considered the best way to ensure security, and thus there is hardly any consideration of establishing alternatives to operate an efficient and stable communication network. Moreover, security for management of a commercialized communication network and network management solution may be accompanied by immense costs, making it more difficult to make new attempts. Therefore, to improve the conditions for the current supervisory control network of purification plants, this study developed a industrial security L2 switch that supports modbus TCP(Transmission Control Protocol) communication and encryption function of the transmission section. As a result, the communication security performance improved significantly, and the cost for implementing the network management system using Historical Trend and information of HMI(Human Machine Interface) could be reduced by approximately KRW 200 million. The results of this study may be applied to systems for gas, electricity and social safety nets that are infrastructure communication networks that are similar to purification plants.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.