• 제목/요약/키워드: Modal Test

검색결과 717건 처리시간 0.028초

다단 천음속 압축기의 유동 불안정성에 관한 실험적 연구 (Experimental Research on Aerodynamic Instabilities in a Multi Stage Transonic Axial Compressor)

  • 강영석;박태춘;황오식;임형수;양수석
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.12-19
    • /
    • 2012
  • This study presents unsteady and unstable characteristics of three stage transonic axial compressor, developed by Korea Aerospace Research Institute. As approaching to the unstable operating region at the 103% design speed of the compressor, a modal type stall precursor appears in front of highly loaded 3rd rotor row at first, and it propagates to the upstream. On the contrary, actual stall cell initiates from the stall precursor in front of the 1st rotor row, and it propagates to the downstream of the compressor. After the stall region reached the 3rd stage and stall cell rotates circumferentially about 360 deg, it develops to one dimensional compressor surge mode. It shows a mild surge behaviour with 3~4 Hz frequency. From the test data, it can be suggested that there is a priority to give an optimum blade loading distributions to construct a multi stage transonic axial compressor stages either to secure more stable compressor operating ranges, or to maximize the compressor efficiency.

헬리콥터용 무베어링 로터 시스템의 강성 및 고유 진동수 측정 (The Measurement Test of Stiffness and Natural Frequencies for Bearingless Rotor System of Helicopter)

  • 윤철용;김덕관
    • 한국소음진동공학회논문집
    • /
    • 제25권12호
    • /
    • pp.881-887
    • /
    • 2015
  • The stiffness and natural frequencies for blades, flexbeam, and torque tube of bearingless rotor system are measured to determine the material input properties such as mass distributions and stiffness distribution for the rotor dynamics and load analysis. The flap stiffness, lag stiffness, and torsional stiffness are calculated by measuring section strain or twist angle, gages position, and applied loads through bending and twist tests. The modal tests are undertaken to find out the natural frequencies for flap, lag, torsion modes in non-rotating conditions. The stiffness values and mass properties are tuned and updated to match prediction frequencies to the measured frequencies. The rotorcraft comprehensive code(CAMRAD II) is used to analyze the natural frequencies of the specimens. The analysis results with the updated material properties agree well with the measured frequencies. The updated properties will be used to analyze the rotor stability, dynamic characteristics and loads for the rotor rotation test in a whirl tower.

고속열차 감속기의 상시감시시스템 설계 및 가변속주행시 안정성 향상을 위한 동특성해석 (Dynamic Characteristics Analysis for the Online Monitoring System Designing KTX MRU and Improvement of the Stability Related Variable High Speed)

  • 박병수;김진우;최상락;송영천
    • 한국소음진동공학회논문집
    • /
    • 제23권4호
    • /
    • pp.301-307
    • /
    • 2013
  • MRU(motor reduction unit) for KTX is a assembled complex structure that is equipped with a lot of parts at the express train KTX and that is the core power source operating variable speeds. This study is recorded the dynamic characteristics analysis results tested by EMA which is done through the parts and assembly test, transient analysis and stoped train test in order to design the online monitoring system for KTX MRU. And the mode shapes result from critical vibration frequency explain the relation with variable speeds of express train over 250 km/hr. Also these variable speeds make variable operational frequencies at pinion, axle gear mesh frequency and normal bearing fault frequencies. As the specified speed can make resonance with natural frequencies of the MRU, for the train operating stability, this study also presents the MRU's critical speeds calculated by the each train speed.

안전도를 고려한 전동 틸트/텔레스코픽 조향주의 해석 및 설계 (Analysis and Design of a Motor Driven Tilt/Telescopic Steering Column for Safety Improvement)

  • 신문균;홍성우;박경진
    • 대한기계학회논문집A
    • /
    • 제24권6호
    • /
    • pp.1479-1490
    • /
    • 2000
  • The design process of the motor driven tilt/telescopic steering column is established by axiomatic design approach in conceptual design stage. By selecting independent design variables for improvin g performance of the steering system, each detailed design can be carried out independently. In the detailed design, the safety in crash environment and vibration reduction are considered. An occupant analysis code SAFE(Safety Analysis For occupant crash Environment) is utilized to simulate the body block test. Segments, contact ellipsoids and spring-damper elements are used to model the steering column in SAFE. The model is verified by the result of the body block test. After the model is validated, the energy absorbing components are designed using an orthogonal array. Occupant analyses are performed for the cases of the orthogonal array. Final design is determined for the minimum occupant injury. For vibrational analysis, a finite element model of the steering column is defined for the modal analysis. The model is validated by the vibration experiment. Size and shape variables are selected for the optimization process. An optimization is conducted to minimize the weight subjected to various constraints.

Wind load estimation of super-tall buildings based on response data

  • Zhi, Lun-hai;Chen, Bo;Fang, Ming-xin
    • Structural Engineering and Mechanics
    • /
    • 제56권4호
    • /
    • pp.625-648
    • /
    • 2015
  • Modern super-tall buildings are more sensitive to strong winds. The evaluation of wind loads for the design of these buildings is of primary importance. A direct monitoring of wind forces acting on super-tall structures is quite difficult to be realized. Indirect measurements interpreted by inverse techniques are therefore favourable since dynamic response measurements are easier to be carried out. To this end, a Kalman filtering based inverse approach is developed in this study so as to estimate the wind loads on super-tall buildings based on limited structural responses. The optimum solution of Kalman filter gain by solving the Riccati equation is used to update the identification accuracy of external loads. The feasibility of the developed estimation method is investigated through the wind tunnel test of a typical super-tall building by using a Synchronous Multi-Pressure Scanning System. The effects of crucial factors such as the type of wind-induced response, the covariance matrix of noise, errors of structural modal parameters and levels of noise involved in the measurements on the wind load estimations are examined through detailed parametric study. The effects of the number of vibration modes on the identification quality are studied and discussed in detail. The made observations indicate that the proposed inverse approach is an effective tool for predicting the wind loads on super-tall buildings.

Wind-induced lateral-torsional coupled responses of tall buildings

  • Wu, J.R.;Li, Q.S.;Tuan, Alex Y.
    • Wind and Structures
    • /
    • 제11권2호
    • /
    • pp.153-178
    • /
    • 2008
  • Based on the empirical formulas for power spectra of generalized modal forces and local fluctuating wind forces in across-wind and torsional directions, the wind-induced lateral-torsional coupled response analysis of a representative rectangular tall building was conducted by setting various parameters such as eccentricities in centers of mass and/or rigidity and considering different torsional to lateral stiffness ratios. The eccentricity effects on the lateral-torsional coupled responses of the tall building were studied comprehensively by structural dynamic analysis. Extensive computational results indicated that the torsional responses at the geometric center of the building may be significantly affected by the eccentricities in the centers of mass and/or rigidity. Covariance responses were found to be in the same order of magnitude as the along-wind or across-wind responses in many eccentricity cases, suggesting that the lateral-torsional coupled effects on the overall wind-induced responses can not be neglected for such situations. The calculated results also demonstrated that the torsional motion contributed significantly to the total responses of rectangular tall buildings with mass and/or rigidity eccentricities. It was shown through this study that the framework presented in this paper provides a useful tool to evaluate the wind-induced lateral-torsional coupled responses of rectangular buildings, which will enable structural engineers in the preliminary design stages to assess the serviceability of tall buildings, potential structural vibration problems and the need for a detailed wind tunnel test.

월유출량의 모의발생에 관한 비교 연구 (Comparative Studies on the Simulation for the Monthly Runoff)

  • 박명근;서승덕;이순혁;맹승진
    • 한국농공학회지
    • /
    • 제38권4호
    • /
    • pp.110-124
    • /
    • 1996
  • This study was conducted to simulate long seres of synthetic monthly flows by multi-season first order Markov model with selection of best fitting frequency distribution, harmonic synthetic and harmonic regression models and to make a comparison of statistical parameters between observes and synthetic flows of five watersheds in Geum river system. The results obtained through this study can be summarized as follow. 1. Both gamma and two parameter lognormal distributions were found to be suitable ones for monthly flows in all watersheds by Kolmogorov-Smirnov test. 2. It was found that arithmetic mean values of synthetic monthly flows simulated by multi-season first order Markov model with gamma distribution are much closer to the results of the observed data in comparison with those of the other models in the applied watersheds. 3. The coefficients of variation, index of fluctuation for monthly flows simulated by multi-season first order Markov model with gamma distribution are appeared closer to those of the observed data in comparison with those of the other models in Geum river system. 4. Synthetic monthly flows were simulated over 100 years by multi-season first order Markov model with gamma distribution which is acknowledged as a suitable simulation modal in this study.

  • PDF

중공부가 있는 다단계 긴장 PSC 거더의 동특성 실험 및 해석 (Dynamic Test and Analysis of Multilevel Post-tensioned PSC Girder with Holed Web)

  • 박봉식;조재열;한만엽
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.11-12
    • /
    • 2010
  • 복부에 중공부가 있는 PSC 거더는 여러 가지 이점이 있다. 중공부에 정착부를 두어 프리스트레싱힘을 단계적으로 도입할 수 있으며 길이가 동일한 경우 거더의 중량을 줄일 수가 있고, 같은 중량인 경우 경간을 더 늘일 수 있다. 그리고 빔에 의한 조망권의 간섭도 줄일 수 있다. 본 연구에서는 복부에 여러 개의 원형 개구부를 가지고 있는 50m 실물 다단계 긴장 PSC 거더를 제작하여 모달테스트를 수행하였다. 모달테스트를 위한 가진방법으로 거더의 중앙에 가진기를 설치하여 일정 주파수 단위로 가진시킴으로써 정확한 주파수응답을 얻고자 하였다. 얻어진 주파수응답을 FFT와 PSD를 통하여 거더의 고유진동수와 감쇠비를 추정하였고 이를 Midas FEA를 이용한 해석결과와 비교하였다.

  • PDF

상용차용 SCR 머플러의 방사소음 개선에 관한 연구 (A Study on the Improvement of Radiated Noise in SCR Muffler of Commercial Vehicle)

  • 이동원;김완수;배철용;김찬중;권성진;이봉현
    • 한국소음진동공학회논문집
    • /
    • 제18권8호
    • /
    • pp.816-822
    • /
    • 2008
  • This study presents the design modification for SCR muffler of a commercial vehicle. Its main objective is the reduction of radiated noise at SCR muffler. For this study, the research of five steps were achieved by experimental and CAE analysis. First step is the measurement of radiated noise using impact-acoustic test. Second step is the source identification using experimental modal analysis. The cause of radiated noise source is confirmed by the resonance of end plates at SCR muffler. Third step confirms the possibility of resonance avoidance using SDM analysis applied the mass control. Fourth step is the suggestion of design modification which is the change of mode shape by CAE analysis. Last step is the verification of design modification using SYSNOISE analysis. Finally, the prototype product applied the countermeasure of resonance evasion was manufactured and the reduction of radiated noise at SCR muffler was confirmed by pass-by noise test.

풍력타워용 부스덕트 포설시스템 개발 (Development of the Bus Duct Installation System for Wind Tower)

  • 이희남;이준근;김봉석;박성희
    • 한국소음진동공학회논문집
    • /
    • 제24권3호
    • /
    • pp.219-226
    • /
    • 2014
  • A bus duct system for wind tower is introduced. A marine cable has been widely used in wind tower or various offshore structures. However, as the electric load capacity is increases, large number of cable lines must be used to cover the huge amount of electric capacities. Therefore, the installation of the cable lines becomes very difficult due to the heavy weight and volume of the cables. On the other hand, by using a single bus duct system line, the power capacity amount of 16 cables can be delivered with significantly compacted form. However, unlike flexible cables, the bus duct is relatively stiff which could generate the resonance phenomenon in the operating condition of the wind tower. In this study, the vibration characteristics of the bus duct are investigated and its long-term reliability during the life time of the wind tower is verified.