• 제목/요약/키워드: Modal Coupling

검색결과 213건 처리시간 0.02초

모드 연성을 수반하는 분할 모형의 비틀림 감쇠비 추정 (Torsional Damping Estimation of a Segmented Hull Model with Modal Coupling)

  • 김유일;박성건
    • 대한조선학회논문집
    • /
    • 제53권6호
    • /
    • pp.482-493
    • /
    • 2016
  • The identification of modal damping of a segmented hull model with torsional response is difficult task due to the coupling of modal response. This is because the 1st and 2nd torsional vibration modes are closely spaced in frequency domain leading to the situation that the modal decomposition is difficult to achieve by simple band-pass filter. Present study applied several different modal decomposition methods to derive the damping ratio of different modes. The modal decomposition methods considered in this study are simple band-pass filter, Hilbert vibration decomposition, Wavelet transform and proper orthogonal decomposition. Coupled free decay signal obtained from the torsional hammering test on a segmented hull model was processed with four different methods and the derived damping ratios were compared with each other. Discussions also have been made on the pros and cons of the different methodologies.

진동-음향 연성계의 모드특성에 대한 연구 (A Study on the Modal Characteristics of the Vibration-Acoustic Coupled System)

  • 김석현
    • 산업기술연구
    • /
    • 제16권
    • /
    • pp.239-245
    • /
    • 1996
  • Modal parameters determine the frequency response characteristics of vibration system or acoustic system. When the two systems are fully coupled, however, coupling changes the vibrational and acoustic model parameters into those of the coupled system. In this case, it is very difficult to obtain the modified model parameters and response characteristics. In this paper, coupling effect is analytically investigated on the natural frequency, mode and frequency response characteristics. The result can be applied to understand and to design the frequency response characteristics of the vehicle passenger compartment.

  • PDF

Optical Power Transfer of Grating - Assisted Directional Coupler with Three - Guiding Channels : TM modes Case

  • Ho, Kwang-Chun;Ho, Kwang-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제8권4호
    • /
    • pp.149-155
    • /
    • 2004
  • Newly developed modal transmission-line theory(MTLT) is used to analyze rigorously the optical power distribution in grating-assisted directional couplers(GADCs) with three guiding channels. By defining a novel coupling efficiency ${\eta}$ amenable to the rigorous analytical solutions of modal transmission-line theory, we explicitly evaluate the power coupling and distribution of TM modes. The results reveal that the incident power is sensitively partitioned through three output channels in terms of such grating parameters as the grating period, the duty cycle, and the operating wavelength.

원형 외팔보의 응답에서의 비선형 현상 (Non-linear Phenomenon in the Response of Circle Cantilever Beam)

  • 김명구;이흥식;조종두
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.445-451
    • /
    • 2005
  • This paper is the result of a experimental study about non-linear one to one modal coupling of a flexible circular cantilever beam which was transversely excited with harmonic excitation. It was proved that 2 order jumping in out of plane was caused by jump phenomenon in in-plane of flexible circular cantilever beam, because of non-linear coupling. In addition, cantilever beam showed hardening spring characteristics in in-plane and softening spring characteristics in out-of-plane.

원형 외팔보의 응답에서의 비선형 현상 (Non-linear Phenomenon in the Response of Circle Cantilever Beam)

  • 김명구;이흥식;조종두
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.129-133
    • /
    • 2004
  • This paper is the result of a experimental study about non-linear one to one modal coupling of a flexible circular cantilever beam which was transversely excited with harmonic excitation. It was proved that 2 order jumping in out of plane was caused by jump phenomenon in in-plane of flexible circular cantilever beam, because of non-linear coupling. In addition, cantilever beam showed hardening spring characteristics in in-plane and softening spring characteristics in out-of-plane.

  • PDF

입구와 유연한 구조물로 구성된 경계를 가지는 구조-음향 연성계의 수학적 표현 (A Mathematical Formulation of the Structural-acoustic System with an Opening and a Flexible Structure)

  • 서희선;김양한
    • 한국소음진동공학회논문집
    • /
    • 제15권5호
    • /
    • pp.527-535
    • /
    • 2005
  • This paper explains a general coupling system in terms of the system parameters. impedance of a cavity or mobility of a structure. To easily access the mechanism of the structural-acoustic coupled system, a simple expression is derived. A general coupled equation is also derived of a general coupled problem constituted a flexible structure and an opening boundary in terms of vector and matrix notation, and is analyzed the coupling phenomena using the understanding acquired simple coupled system. The paper shows that the general coupled equation is expanded version of the simple coupled equation by some limiting checks. The paper also shows that the degree of coupling is proportioned to a stiffness of the acoustic system and a modal coupling coefficient, but is in inverse proportion to a mass of the structural system and the difference of the excitation frequency and resonant frequency of the acoustic or structural system.

잔향수조의 구조-음향 연성효과에 관한 수치 및 실험적 고찰 (Numerical and Experimental Investigation on Structure-acoustic Coupling Effect in a Reverberant Water Tank)

  • 박용;김국현;조대승;이종주
    • 대한조선학회논문집
    • /
    • 제56권1호
    • /
    • pp.94-101
    • /
    • 2019
  • Underwater acoustic power should be measured in a free field, but it is not easy to implement. In practice, the measurement could be performed in a reverberant field such as a water-filled steel tank and concrete tank. In this case, the structure and the acoustic field are strongly or weakly coupled according to material properties of the steel and water. So, characteristics of the water tank must be investigated in order to get the accurate underwater acoustic power. In detail, modal frequencies, mode shapes of the structure and frequency response functions of the acoustic field could represent the characteristics of the reverberant water tank. In this paper, the structure-acoustic coupling has been investigated on a reverberant water tank numerically and experimentally. The finite element analysis has been carried out to estimate the structural and acoustical modal parameters under the dry and water-filled conditions, respectively. In order to investigate the structure-acoustic coupling effect, the numerical analysis has been performed according to the structure stiffness change of the water tank. The acoustic frequency response functions were compared with the numerical analysis and acoustic exciting test. From the results, the structural modal frequencies of the water-filled condition have been decreased compared to those of the dry condition in the low frequency range. The acoustic frequency response functions under the coupled boundary conditions showed different patterns from those under the ideal boundary conditions such as the pressure release and rigid boundary condition, respectively.

Modal transformation tools in structural dynamics and wind engineering

  • Solari, Giovanni;Carassale, Luigi
    • Wind and Structures
    • /
    • 제3권4호
    • /
    • pp.221-241
    • /
    • 2000
  • Structural dynamics usually applies modal transformation rules aimed at de-coupling and/or minimizing the equations of motion. Proper orthogonal decomposition provides mathematical and conceptual tools to define suitable transformed spaces where a multi-variate and/or multi-dimensional random process is represented as a linear combination of one-variate and one-dimensional uncorrelated processes. Double modal transformation is the joint application of modal analysis and proper orthogonal decomposition applied to the loading process. By adopting this method the structural response is expressed as a double series expansion in which structural and loading mode contributions are superimposed. The simultaneous use of the structural modal truncation, the loading modal truncation and the cross-modal orthogonality property leads to efficient solutions that take into account only a few structural and loading modes. In addition the physical mechanisms of the dynamic response are clarified and interpreted.

Experiment of A Cavity-gap Coupling Model for The Safty and Comfort of A Driving Condition

  • Kang, Sang-Wook;Loh, Byoung-Gook
    • International Journal of Safety
    • /
    • 제7권1호
    • /
    • pp.5-9
    • /
    • 2008
  • For the purpose of controlling the coupling between the car body panels and passenger compartment, experimental investigation of an acoustic cavity with an air gap is carried out to reveal how the air gap influences the acoustic modal characteristics of the cavity. The acoustic modal characteristics of the cavity is closely related with the booming noise. The experimental results show that a very small air gap can change the acoustic modal characteristics of the cavity and, as a result, the air gap can be an important factor in controlling the booming noise for comfortable and safe passenger compartment.

비고전적으로 감쇠하는 선형 진동시스템의 주파수응답 (Frequency Response of Nonclassically Damped Linear Systems)

  • 황재혁;남창호
    • 대한기계학회논문집
    • /
    • 제17권11호
    • /
    • pp.2742-2751
    • /
    • 1993
  • Nonclassically damping domes from drastic variations of energy absorption rates of the materials in different parts of structures, or from the external damping sources inserted into the structures. In this study, an approximate method to calculate the frequency response of a method is superior to other approaches in respect of computational effort and accuracy. In addition, when frequency response is calculated by neglecting the off-diagonal elements of modal damping matrix, a criterion to ensure small errors is derived. In is shown that the criterion can be described as the vector sum of each modal coupling to the corresponding mode.