• 제목/요약/키워드: Mock-Up Test

검색결과 355건 처리시간 0.033초

자연 기화식 가습기와 초음파 가습기의 PM10 제거성능 (A Study on the Removal Performance of PM10 by the Air-washer and the Ultrasonic Humidifier)

  • 이주호;김선숙;박성관;박준형;이윤규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.720-724
    • /
    • 2008
  • The purpose of this study is to evaluate the PM10 removal efficiencies of an Air-washer and an Ultrasonic humidifier by mock-up experiments. The concentrations of PM10 were measured at 5 minute intervals using $\beta$-Ray method. The average PM10 removal efficiency of the Air-washer was 79.8%, while the PM10 concentrations increased with the operation of Ultrasonic humidifier. In the case of operating the Air-washer, the R.H(Relative Humidity) level of the test room was maintained at around 45%, regardless of initial R.H condition. The R.H of the test room with Ultrasonic humidifier was influenced by the initial R.H condition.

  • PDF

알루미노 실리케이트계 내화보드의 내화성능 및 현장적용성 평가 (An Evaluation of Fire Resistance and Mock-up Test of the Alumino-silicate Fire Resistant Board)

  • 김두호;박동철;김우재;이세현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 2부
    • /
    • pp.43-47
    • /
    • 2010
  • The use of high-strength concrete has increased for its excellent structural stability as buildings become higher and bigger than ever before in Korea and overseas recently. The functional requirement of building materials has also been bolstered so for the high -performance, high-quality construction materials to be used more extensively. However, the internal structure of the high-strength concrete is very dense so spalling can be caused during fire. The spalling in turn can cause critical structural damages followed by the fatal consequences, demolition of the building. Therefore, ensuring fire safety for high-rise buildings is assumed to be urgent. Alumino-silicate fire resistant board producing technology has been developed in situations that new materials with excellent fire resistance and easy installation has been sought. The alumino-silicate fire resistant board turned out to exhibit not only fire resistance and excellent physical and dynamical characteristics but also excellent onsite applicability and easy process and transportation after completing Mock-up test. Its excellence as a high-performance building materials was proven.

  • PDF

폴리론 화이버를 혼입한 고강도 RC 보 및 슬래브의 내화특성 분석을 위한 Mock-Up 실험 (Mock-Up Test for the Fire Resistance Analysis of High Strength RC Beam and Slab Using the Polylon Fiber)

  • 손호정;황동규;한창평;한민철;양성환;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.93-96
    • /
    • 2009
  • The objective of this study is to analyze the insulation characteristics of the polylon hybrid fiber inserted high-strength RC beam and slab produced as a single body and the results of this study can be summarized as follows. In the spalling mechanism as an insulation characteristic, the slab of the single body type specimen shows an exposure in concrete covers at the center of slab and that leads to the spalling, which exposures reinforcing bars. In the case of the beam, the spalling was presented at several sections as a type of peel spalling before and after 10 minutes from the insulation test. Whereas, although the internal temperature history of concrete represents the highest range as 581℃ in the case of the center of the bottom of beam base, it can be considered that it satisfies the regulation of insulation certification.

  • PDF

건축물 시공 자동화 시스템을 위한 자립형 철골 접합부의 시공성 분석 (Constructibility Analysis of Self-supported Steel Joint for Automated Construction System)

  • 김동건;양성우;김태훈;신윤석;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.1-4
    • /
    • 2009
  • Construction automation and robotics are being introduced as an efficient alternative to overcome troubles caused by lack of skilled labors. To accomplish effective automated construction system, design for automation(DFA) should be performed in parallel with the development of core technologies such as control and sensing of robots. In Korea, the development of robotic crane-based construction automation(RCA) system is progressing, and the research group has recently developed newly designed steel joint to improve the efficiency of the system. However, performance of the new system should be examined prior to its application on construction sites. Therefore, This study analyzed performance of the new steel frame focused on its constructibility by carrying out mock-up test. As a result, the steel frame satisfied the standards of allowable stress and deflection. It also enables to reduce the time for installation.

  • PDF

UHF Sensor를 이용한 SF6 절연 MV 개폐기의 부분방전 검출 시스템 (Partial Discharge Monitoring for $SF_6$ Insulated MV Switchgear using UHF sensors)

  • 이도훈;강원종;신양섭;김영근;오일성;김동명;권태호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2040-2041
    • /
    • 2007
  • In this paper, the UHF PD(Partial Discharge) sensors for $SF_6$ insulated MV $SF_6$ switchgear have been proposed and related investigations have been performed in order to detect the PD which were produced inside the MV $SF_6$ switchgear. Firstly, the internal type UHF PD sensor based on spiral antenna theory has been developed. This type sensor is highly sensitive and has lowly effect on by on-site noise. Secondly, the external type UHF PD sensor was developed based on log periodic antenna concept. This type sensor is removable and detectable for operating switchgear. These sensors were designed and simulated using RF simulation tool. In order to verify the sensitivity of these sensors, we performed the on-site test using the mock-up switchgears including the artificial defects which were the protrusion on high voltage conductor, free moving metal particle and surface defect on insulator. These mock-up switchgear were installed on the test distribution line.

  • PDF

하이브리드 복합재 철도차량 차체의 화재 안전성 평가연구 (A Study on the Fire Safety of a Hybrid Composite Train Carbody)

  • 김정석;이덕희;정우성;조세현
    • Composites Research
    • /
    • 제21권4호
    • /
    • pp.1-6
    • /
    • 2008
  • 본 논문에서는 탄소/에폭시 면재와 알루미늄 허니콤 심재를 갖는 바디와 스테인레스 언더프레임을 갖는 철도차량 차체에 대한 화재안전성평가 시험을 수행하였다. 이를 위해 실규모 차체를 제작하고 이를 이용하여 시험을 수행하였다. 시험에 적용된 차체는 내장재가 포함되지 않은 차체와 내장재를 포함을 차체 두가지를 이용하였으며 시험조건은 대구지하철 화재사고 시나리오에 근거하여 설정하였다. 시험결과 차체 및 내장재 표면의 최대온도는 각각의 발화온도에 미치지 못함을 확인하였고, 차체 내부에 화염전파도 발생하지 않았다.

Barrier Free Accessibility to Trains for All

  • Rentzsch, Manfred;Seliger, Denis;Meissner, Thomas;Wessner, Claudia
    • International Journal of Railway
    • /
    • 제1권4호
    • /
    • pp.143-148
    • /
    • 2008
  • This paper is the output of a collaborative European project concerning the barrier free accessibility for disabled persons to regional and long distance trains in Europe. Disabled people represent around 13% of the population in Europe. This is approximately 63 million people. The range of disabilities includes people with reduced mobility including wheel chair users, viewing and hearing impaired people and other forms of impairment. Improving accessibility aims at contributing to the provision of public transport services to all citizens in an equitable way. The purpose of the project was to analyse and to evaluate the existing solutions at selected European railways for all required modules at the entrance (doors, information and safety solutions), to derive a design concept, to develop a mock-up in meeting the needs of rail travellers with the above mentioned impairments and to test it with user groups. The project also aims at deriving components for the determination of standards. The EUPAX Design Mock-up test was performed to verify the advantages of the layout of the train segment including the different modules such as access area (including the access door, gaps between platform and train as well as boarding aid devices), entrance vestibule, information systems inside and outside the train, emergency facilities, toilet with all conveniences and the additional test arrangements regarding push buttons, steps and emergency equipment. For this purpose a questionnaire was developed for the assessment of the EUPAX segment and the additional test arrangements. With the help of this questionnaire it was possible to execute a quantitative and qualitative evaluation. During three test phases 67 experts and handicapped persons from 6 countries have evaluated the Industrial Design mock-up based on this questionnaire. The test group covered persons from North (Denmark) to the South (Italy) and from the West (Spain) to the Middle of Europe (Germany). This is especially important for the generalization (harmonisation) of the results for all European countries. According to COST 335 the information for people with reduced mobility should be clear, concise, accurate and timely. So that all information can be received from persons, they must be transferred on at least two of the three possible ways (acoustical, visual, tactile), a so called "2-sense-principle". Based on the results ergonomic specifications/ solutions for the ergonomic design of the access area, the acoustic, visual and tactile information and the emergency devices including the emergency communication system were developed, related to the benefiting passenger groups.

  • PDF

고강도-고성능 콘크리트의 모의 부재 및 실대 구조물 시공 실험 (An Constructive Experiment through Mock-up and Monolith of High-Strength High-Performance Concrete)

  • 김태영;이영호;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.357-364
    • /
    • 1997
  • In this experiment high-strength concrete of good workability is made by means of either replacing unit cement quantity to fly-ash by 20% or using low heat cement to reduce the internal hydration heat suggested as the fault of concrete. Concrete is poured through ready mixed concrete to test the ability of applying to the substantial works and is carried out the test of flowing and core strength and record of temperature of imitating specimens. It is capable to apply high-strength concrete replaced to fly-adh 20% to the substantial works through the experiment

  • PDF

도로 및 비탈면 유실 항구적 긴급복구를 위한 골재망 콘크리트 활용기술 개발 (Emergency and Permanent Repair Technology for Damaged Road Bases and Slopes using Gravel-Netting Concrete)

  • 김용재;정해국;김승원;박철우
    • 한국도로학회논문집
    • /
    • 제20권2호
    • /
    • pp.9-17
    • /
    • 2018
  • PURPOSES : The frequency and severity of natural disasters such as torrential rain or typhoons have become increasingly significant worldwide. Events such as summer typhoons and localized torrential downpour can cause severe damages to a residential area and road networks, resulting in serious harm to the daily lives of people, especially in rural areas by isolating residents from road networks. An immediate and emergency repair technology for the collapsed road networks is urgently needed. This study introduces a new technology to repair road bases or slopes. METHODS : The development of new technology for emergency and permanent repair consists of first, packing of cement paste-coated gravel, second, combining appropriate equipment, and third, conducting a field applicability test. In this research, the compressive strength of cement pastecoated gravel, gravel-netting concrete properties, and packing efficiency were determined, and a full scale field mock-up test was carried out. RESULTS : The compressive strength of the cement paste-coated gravel concrete satisfied the required limit for road base of 5 MPa after 7 days. With appropriate netting materials and packing size, gravel-netting concrete was successful up to a slope of 1:1.5. The full scale field mock-up test showed efficiency in the field and penetration resistance performance. CONCLUSIONS : The new technology of emergency and permanent repair for damaged road bases and slopes, introduced in this study, showed satisfactory performance. The technology is expected to be applied in the field when construction procedures and quality specifications are made.

수직 외벽면 적용 BIPV의 Mock-up 실험연구 (A Study on the Mock-up test for applying BIPV in the external curtain Wall)

  • 이한명;오민석;김회서
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.110-118
    • /
    • 2009
  • This research is an experimental study on BIPV Power performance of See-through a-si and Light-through applying external curtain wall. In case of See-through a-si Photovoltaic, appropriateness of facade applying standard($950\;{\times}\;980mm$) large($950\;{\times}\;1960mm$)area photovoltaic was examined. Transparent performance was also investigated through Power simulation according to angles and seasons of See-through a-si and Light-through Photovoltaic so that Power output was surveyed with using designed and manufactured Mock-up. When comparing See-through a-si to Light-through Photovoltaic for simulation Power output on angles based on full south aspect, which the result was that See-through a-si Power output according to Light-through Power output was the highest of 65.5% when applying a 90 degree angle. Monthly accumulated average Power output during winter seasons (December, January and February) applying a vertical plane on full south aspect was analyzed, which results in 66.37W/h of See-through a-si and 139.1 W/h of Light-through. See-through a-si Power output showed 47.7% in comparison with Light-through transparent. Also monthly, hourly average Power efficiency according to solar radiation during winter seasons (December, January and February) was that 4.7% of See-Through a-si and 9.8% of Light-through.