• Title/Summary/Keyword: Mock Up

Search Result 802, Processing Time 0.026 seconds

Strength Property and Mock-up Test of the High Performance Concrete with Emulsified Refined Cooking Oil (유화처리 정제식용유(ERCO) 사용에 따른 고성능 콘크리트의 Mock-up 및 강도특성)

  • Jo, Man-Ki;Kang, Byeong-Hoe;Lee, Dong-Gyu;Park, Kyu-Yeon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.136-137
    • /
    • 2014
  • In this study, fundamental performances of high strength concrete with ERCO has been analysed according to mock-up test. The following results could be made as the conclusion. For the fresh concrete, flowability and air content decreased with the addition of ERCO, and all the specimens satisfied the target range. For the strength properties, all the specimens with different nominal strength showed higher compressive srength than Plain which with 0% dosage of ERCO.

  • PDF

Autogenous Property and Mock-up Test of the High Performance Concrete with Emulsified Refined Cooking Oil (유화처리 정제식용유(ERCO) 사용에 따른 고성능 콘크리트의 Mock-up 및 자기수축특성)

  • Jo, Man-Ki;Kim, Jun-Ho;Lee, Dong-Gyu;Park, Kyu-Yeon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.134-135
    • /
    • 2014
  • In this study, mock-up test for high strength concrete with ERCO has been carried to analyse the effect of autogenous shrinkage reducing of using ERCO. The following results could be made as the conclusion. Results of EIS were lower than 2.5 and showed good resistance for separation of materials. For the setting time, specimen with ERCO showed delay of setting comparing with Plain. For the autogenous shrinkage, as the generation of saponification, capillary pores inside the concrete were filled by soap and the autogenous shrinkage has been obviously decreased. It could be identified that using ERCO in high strength showed good effect on reducing autogenous shrinkage in high strength concrete.

  • PDF

Mock-up Test of Low Heat Concrete Using High Volume Mineral Admixture (혼화재를 다량 사용한 저발열 콘크리트의 모의부재실험)

  • Kim, Yong-Ro;Song, Young-Chan;Kim, Hyo-Rak;Park, Jong-Ho;Yoo, Jung-Hoon;Jeong, Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.31-34
    • /
    • 2011
  • In this study, for the evaluation of field application of low heat concrete using high volume mineral admixture, the characteristics of hydration heat generation and engineering properties of low heat concrete was investigated by mock-up test according to the replacement ratio of mineral admixture. Also, it was evaluated the compressive strength of low heat concrete with curing temperatures and ages for effective concrete mix design considering seasonal change.

  • PDF

Mock-Up Test On Anti-Freezing Method with Double bubble Sheets Subject to Cold weather Banking (이중버블시트를 이용한 동상방지공법의 동절기 성토공사 Mock-up 실험)

  • Hong, Seak-Min;Son, Ho-Jung;Oh, Chi-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.33-34
    • /
    • 2011
  • In this study, using the double bubble sheet to anti-freezing method in winter the soil embanking Mock up as a part of the development process was carried out. As results, two layers of the double bubble sheet effect 12.6℃~13.8℃ temperature difference of out door temperature that proved superior insulation and thermal performance of the double bubble sheet.

  • PDF

The Mock-up Test of the Exposed Concrete by Applying the Flowing Concrete Method (유동화 공법을 적용한 노출 콘크리트 배합의 현장적용성에 관한 Mock-up Test)

  • Son, Ho-Jung;Park, Kyung-Taek;Hong, Seak-Min;Oh, Ch-Hyun;Han, Cheon-Goo;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.165-167
    • /
    • 2011
  • This study is to evaluate the feasibility of the mix design for exposed concrete. Mock-up sized specimens were prepared, and a flowing concrete method was selected for placement. Results showed that the fluidity and air content of fresh concrete achieved target values, the compressive strength at 7 days was 27 MPa, and surface roughness was in the range of between around 1.53 and 1.68 ㎛, which was in the quality level. Therefore it is concluded that the proposed mix design for exposed concrete can be applied in practice.

  • PDF

Design of 3 Dimensional Digital Mock-up using the PDM of Highspeed Tilting EMU(TTX) (틸팅전동차 PDM을 이용한 3차원 디지털 Mock-Up 설계에 관한 연구)

  • Han, Seong-Ho;Song, Young-Su;Lee, Su-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.123-125
    • /
    • 2004
  • Tilting train has been developed to increase the operational speed of the trains on conventional lines which have many curves. This train are tilted at curves to compensate for unbalanced carbody centrifugal acceleration to a greater extent than compensation produced by the track cant, so that passengers do not feel centrifugal acceleration and thus trains can run at higher speed at curves. This paper developed 3 Dimensional Digital Mock-UP using PDM(product data managemnet) to make a system engineering of TTX(tilting train express) wiht maximum operation speed 180 km/h.

  • PDF

Reliability evaluation of recliner by multi moulding Fineblanking (다단 성형 파인 블랭킹을 적용한 리클라이너의 신뢰성 평가)

  • Lee, K.Y.;Nam, K.W.;Moon, C.K.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.59-66
    • /
    • 2011
  • This study was carried out the experimental and the analysis for process of carburizing and quenching, evaluated the reliability of mock-up. Carburizing of comer of rock gear was higher than body regardless of condition of eight processes, and the end of gear tooth was more highly distributed than root. Hardness of surface shows the maximum value and was decreased linear to depth direction. The result of analysis wasn't nearly the heat deformation. In mock-up, tooth flank increased 0.096%, thickness of tooth decreased 0.11% and body increased 0.11%. It had no trouble with assembly and operation like this. The mock-up of recliner for automobile was secured stability by four types of test.

A Study on Concentration Change of Volatile Organic Compounds; VOCs by using Mock-up Test (실물실험을 통한 개별 VOC의 농도변화에 관한 연구)

  • Kim Chang-Nam;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.487-495
    • /
    • 2005
  • Recently, due to the airtightness of buildings or the misuse of building materials, we have been witness SHS (Sick House Syndrome) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. As a result of this situation, we went to restrict the TVOC (Total Volatile Organic Compound) and formaldehyde. But these guidelines concentrated on only TVOC although TVOC are consist of many individual VOC. Therefore, in this study, we will look about concentration change of VOCs (Volatile Organic Compounds) by using Mock-up test. As result of test, the concentration of four individual VOC (Benzene, Toluene, Ethylbenzene, Styrene) showed quitely low level after 7 days. On the other hand the concentration of Xylene and formaldehyde showed low level after 14 days.

A Fundamental Study on Concrete Packing Ability by Placement Method - for H-beam column - (타설방법에 따른 콘크리트의 충전성 컴토를 위한 기초적 연구 - H형강이 있는 기둥을중심으로 -)

  • 강동현;김병천;정근호;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.835-840
    • /
    • 2000
  • The purpose of this study is developing concrete Mixing & placing method that could be adjusted to vertical joint at top-down method. Basic test was consists of general, high fluidity, and high quality mixing concretes and Mock-up test had several placing ways, placing positions. They were examined several placing ways, placing positions with Mock-up model comparison with three mixing concrete to know fluidity characterics. Used with Mock-up model to know packing ability from placing ways and positions. The result of the study like this; High fluidity and High quality concretes show favorable packing ability, especially, in sheath placing way. It was expected to good result in next planned real structure test.

  • PDF

An Evaluation of Daylight Distribution with Korean Traditional Paper and Roller Shading Systems in the Mock-up model (Mock-up 실험을 통한 전통한지와 차양장치의 주광유입 특성 평가)

  • Lee, Soon-Ji;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.85-88
    • /
    • 2008
  • The purpose of this study is to analyze daylight distribution and light characteristics on the Ma-ji and Roller Shade fabric, and to investigate a possibility of using it as a shading system. Using a 1/2 Mock-up model, daylight distribution is analyzed with the Ma-ji and Sun-ji (Korean traditional paper) which have good efficiency and less glare. Ma-ji has the best daylight distribution, so that daylight experiment is conducted with the Ma-ji and Roller Shade fabric. In current office buildings and apartment houses, daylight characteristics of Korean traditional paper windows could be used as preliminary data to develop a window system which makes better daylight performance.

  • PDF