• 제목/요약/키워드: Mock Up

검색결과 802건 처리시간 0.022초

기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구 (A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board)

  • 김혜정;송규동;이윤규
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

적합한 조명시뮬레이션 사용을 위한 주광 시뮬레이션과 Mock-up 실험 비교에 관한 연구 (A Study on the Comparison of the Illuminance Values from Daylight Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation)

  • 김유신;최안섭
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.35-44
    • /
    • 2010
  • 주광은 인공광원보다 심리적 안정과 심리적 신체적 건강 측면 등에서 질적으로 우세하며, 작업능률의 향상에 도움을 주는 것으로 알려져 있다. 또한 쾌적한 빛 환경에 대한 재실자들의 요구가 증가하고 있다. 그러나 주광의 양과 질이 항상 일정하지 않아 예측하기가 어렵기 때문에 이러한 주광의 유용성에도 불구하고 건축설계에 주광을 적극적으로 반영하는 경우가 드물다. 본 연구의 목적은 이러한 주광의 성능을 계량화하고 가시화 할 수 있는 다양한 조명시뮬레이션 소프트웨어(Lightscape 3.2, Relux 2007, Radiance 3.9)를 사용함으로 주광을 예측하고, 도출된 결과 값과 Mock-up 실험의 실측값을 비교 분석을 통하여 조명 시뮬레이션 소프트웨어 활용성을 극대화하는 것이다.

배쳐플랜트배합시험 및 실대부재시험을 통한 콘크리트의 조기강도 발현특성에 관한 실험적 연구 (An Experimental Study on the High Early Strength Development Properties of Concrete according to Batcher Plant Test and Mock-up Test)

  • 이지환;이종석;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.1-5
    • /
    • 2008
  • In this study, batcher plant composition test and mock-up test were carried out to conduct comparison and analysis on flow behavior and strength properties of concrete at early age. As a result, it was found that slump and amount of air in batcher plant composition test reached the target range. As for compressive strength, composition using HESPC showed the most excellent strength development. In mock-up test which was carried out to find out the strength properties, two methods with specimen and core test body both revealed HESPC as the most excellent composition. However, strength estimation with ultrasonic survey presented less reliable data. As a result of the previously conducted indoor composition test and the mock-up test in this study, target performance of concrete at early age was 4day/cycle. It was found that the optimum conditions that meet the required strength, 5MPa/18hr and 14MPa/36hr in mullion and transom are; curing temperature above 15℃, W/B 45%, unit-water 165kg/㎥ and CHC cement.

  • PDF

ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구 (Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior)

  • 김영호;이용수
    • 한국디지털건축인테리어학회논문집
    • /
    • 제13권4호
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.

창고 모델 실물화재 특성에 대한 실험적 연구 (An Experimental Study on the Warehouse Mock-up Fire Test)

  • 권오상;유용호;김흥열
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.47-54
    • /
    • 2010
  • 본 연구에서는 창고 화재 사고의 위험성을 파악하기 위해서 중규모 실물 화재 실험 장비인 룸코너 시험기(Room Corner Tester)를 통해 구축된 단위 구성품의 화재 특성 DB를 바탕으로 화재에 취약할 것으로 판단되는 의류 창고를 실험 모델로 구성하여 실물 화재실험 장비인 라지 스케일 칼로리미터(Large Scale Calorimeter)에서 실물 화재실험을 실시하였다. 창고 모델의($3m{\times}3m{\times}2.4m$) 벽체는 불연등급의 그라스울과 일반 스티로폼 샌드위치 패널로 구성하였다. 실험결과 최대 열방출률은 그라스울 샌드위치 패널 창고모델에서 5MW, 스티로폼 샌드위치 패널 창고모델에서 11MW를 나타내었다.

Analysis of VVER-1000 mock-up criticality experiments with nuclear data library ENDF/B-VIII.0 and Monte Carlo code MCS

  • Setiawan, Fathurrahman;Lemaire, Matthieu;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.1-18
    • /
    • 2021
  • The criticality analysis of VVER-1000 mock-up benchmark experiments from the LR-0 research reactor operated by the Research Center Rez in the Czech Republic has been conducted with the MCS Monte Carlo code developed at the Computational Reactor Physics and Experiment laboratory of the Ulsan National Institute of Science and Technology. The main purpose of this work is to evaluate the newest ENDF/B-VIII.0 nuclear data library against the VVER-1000 mock-up integral experiments and to validate the criticality analysis capability of MCS for light water reactors with hexagonal fuel lattices. A preliminary code/code comparison between MCS and MCNP6 is first conducted to verify the suitability of MCS for the benchmark interpretation, then the validation against experimental data is performed with both ENDF/B-VII.1 and ENDF/B-VIII.0 libraries. The investigated experimental data comprises six experimental critical configurations and four experimental pin-by-pin power maps. The MCS and MCNP6 inputs used for the criticality analysis of the VVER-1000 mock-up are available as supplementary material of this article.

원전 벽체구조물의 철근모듈화 적용을 위한 Mock-Up 실험연구 (The Mock-Up Test for Applying Rebar Modularization to the Wall of Nuclear Power Plant)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.7-8
    • /
    • 2016
  • We are developing the technology for applying the Rebar Modularization Method to the Nuclear Power Plant Structures. To achieve this, we had developed the elementary technology for applying this method to Nuclear Power Plant Structures efficiently and performed the Mock-Up Test by using the developed elementary technology. By analysing this test result, we deduced the problems and found solutions to solve them.

  • PDF

장수명 공동주택 표준모델 개발을 위한 실험주택 건립과 현장적용성 평가 (Constructing Mock-up House and Evaluating Field Application for Development of Standard Long-Life Housing Model)

  • 진주원;장한두;최경렬;박준영
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.167-172
    • /
    • 2008
  • The ultimate objective of this research is to develop the technologies for the construction of 100-year housing as the first task for improving housing environments. The technological development of 100-year housing makes it possible to advance construction technologies and part development, to develop long-life housing with durability and Flexibility responding to customers' needs for future living space. At first, for this purpose, the applications according to the types of the Standard Model of Long-life Housing are proposed to respond to the life-cycle of near-future demographic and social structure, and the construction of the Mock-up House execute based on the location selected during the 2nd year and the basic plan. Then the Standard Model of Long-life Housing are advanced and proposed through evaluating the field applicability of the Mock-Up House.

  • PDF

선박용 판넬의 음향투과손실(STL)의 실험실법 측정과 Mock-up 측정값의 비교 (Comparison of Panel STLs for Ships Measured in Laboratory and Mock-up)

  • 김현실;김봉기;차선일;김영수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.69-72
    • /
    • 2005
  • In this paper, FSTL(field sound transmission loss) measured in the mock-up is studied and compared to the STL measured in laboratory. A mock-up is built by using 6t steel plate, and two identical cabins are made where 25t or 50t panel is used to construct wall and ceiling inside the steel structure. Various wall panels and ceilings are tested, where the effects of U/T, sealing, panel thickness, ceilings are studied. It is shown that the effect of ceiling thickness is negligible and FSTL is lower than STL by 5-7 dB due to several flanking paths.

  • PDF

고부가가치선의 Unit Cabin Mock-up 을 이용한 캐빈소음 저감 연구 (Cabin Noise Reduction using Unit Cabin Mock-up of High Value Ship)

  • 주원호;송근복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.483-484
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value ship such as drill ship and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission, and radiated noise measurements were carried out by using the mock-up of living quarter. From the tests, it was found out that the combined noise level of a unit cabin could be dominated by the radiated noise from wall panel in low frequency range and the design guidelines for the noise control of unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

  • PDF