• Title/Summary/Keyword: Mobility of movement

Search Result 470, Processing Time 0.03 seconds

Efficient Approach for Maximizing Lifespan in Wireless Sensor Networks by Using Mobile Sinks

  • Nguyen, Hoc Thai;Nguyen, Linh Van;Le, Hai Xuan
    • ETRI Journal
    • /
    • v.39 no.3
    • /
    • pp.353-363
    • /
    • 2017
  • Recently, sink mobility has been shown to be highly beneficial in improving network lifetime in wireless sensor networks (WSNs). Numerous studies have exploited mobile sinks (MSs) to collect sensed data in order to improve energy efficiency and reduce WSN operational costs. However, there have been few studies on the effectiveness of MS operation on WSN closed operating cycles. Therefore, it is important to investigate how data is collected and how to plan the trajectory of the MS in order to gather data in time, reduce energy consumption, and improve WSN network lifetime. In this study, we combine two methods, the cluster-head election algorithm and the MS trajectory optimization algorithm, to propose the optimal MS movement strategy. This study aims to provide a closed operating cycle for WSNs, by which the energy consumption and running time of a WSN is minimized during the cluster election and data gathering periods. Furthermore, our flexible MS movement scenarios achieve both a long network lifetime and an optimal MS schedule. The simulation results demonstrate that our proposed algorithm achieves better performance than other well-known algorithms.

Healing of the Bone around Hydroxyapatite-Coated Implants without Primary Bone Contact (초기 골 접촉이 없는 수산화 인회석 피복 임프란트 주위 골의 치유)

  • Cho, Hyung-Soo;Shin, Kwang-Yong;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.2
    • /
    • pp.415-433
    • /
    • 1999
  • Implant stability is the key to long-term successful outcome for osseointegrated implants. To evaluate the initial healing response of bone around HA-coated implants without primary bone contact. 21 HA-coated thread type implants(STERI-OSS?) were placed in the femurs of 5 mongrel dogs, about 1-year old. Implants, 8 mm in length and 3.8mm(experimental 1group), 5.0mm(experimental 2group) and 6.0mm(control group) in diameter, were inserted after 3 holes of 6.0mm in diameter and 10mm in depth were prepared in the surgical sites each dog. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), in order to prevent the ingrowth of upper soft tissue into the gap between bone and implant, and to maintain each implant to be positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 implants were inserted in 2 dogs for mobility test and removal torque test. Fluorescent dyes were injected for the observation of new bone formation in order of $Terramycin^{(R)}$, Arizarin $Red^{(R)}$, and $Calcein^{(R)}$ at an interval of 2 weeks. 3 dogs were sacrificed for histologic observation at 4, 8, and 12-week after placement. Light microscopy and confocal laser scanning microscopy were used to qualitatively characterize the bone around HA-coated implant. 2 dogs were sacrificed for mobility test($Periotest^{(R)}$, Simens AG, Bensheim, Germany) and removal torque test($Autograph^{(R)}$ AGS-1000D series, Japan) at 8 and 12-week after placement The results were as follows: 1. Histologic observation showed that osseointegration occurred to both control and experimental groups as time lapse, but delayed bone healing was revealed in 3.8mm group (experimental 1group), compared to contrtol group and 5.0mm group (experimental 2group). 2. The mobility test showed that the experimental groups had no distinguishable movement during experimental periods of 8 and 12-week, and there was no difference in mobility depending on the gap between bone and implant, and time lapse. 3. The removal torque forces were increased depended on the gaps decreasing between bone and implant, and time lapse. The results suggest that HA-coated implant without primary bone contact, based on guided bone regeneration could obtain its stability in all experimental groups as time lapse, but bone healing was delayed in experimental group of 3.8mm. And the results suggested that studies on correlationship between mobility test and removal torque test for implant stability would be necessary.

  • PDF

A Novel QoS Provisoning Scheme Based on User Mobility Patterns in IP-based Next-Generation Mobile Networks (IP기반 차세대 모바일 네트워크에서 사용자 이동패턴에 기반한 QoS 보장기법)

  • Yang, Seungbo;Jeong, Jongpil
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.25-38
    • /
    • 2013
  • Future wireless systems will be required to support the increasingly nomadic lifestyle of people. This support will be provided through the use of multiple overlaid networks which have very different characteristics. Moreover, these networks will be required to support the seamless delivery of today's popular desktop services, such as web browsing, interactive multimedia and video conferencing to the mobile devices. Thus one of the major challenges in the design of these mobile systems will be the provision of the quality of service (QoS) guarantees that the applications demand under this diverse networking infrastructure. We believe that it is necessary to use resource reservation and adaptation techniques to deliver these QoS guarantee to applications. However, reservation and pre-configuration in the entire service region is overly aggressive, and results in schemes that are extremely inefficient and unreliable. To overcome this, the mobility pattern of a user can be exploited. If the movement of a user is known, the reservation and configuration procedure can be limited to the regions of the network a user is likely to visit. Our proposed Proxy-UMP is not sensitive to increase of the search cost than other schemes and shows that the increasing rate of total cost is low as the SMR increases.

Intra-MARIO: Mobility Management Protocol to Support Intra-PAN Handover with Route Optimization for 6LoWPAN (Intra-MARIO: 6LoWPAN에서 PAN 내부 핸드오버를 최적화된 경로로 지원하기 위한 이동성 프로토콜)

  • Ha, Min-Keun;Kim, Seong-Hoon;Hong, Sung-Min;Kim, Dae-Young;Yoe, Hyun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.12
    • /
    • pp.1189-1193
    • /
    • 2010
  • Mobility management is one of the most important research issues in 6LoWPAN, Since the IP-WSN application domain is expanded to real-time applications such as healthcare and surveillance systems, a fast and seamless handover becomes an important criterion in 6LoWPAN. However, a draft of IETF 6LoWPAN WG for mobility support does not decrease handover delay. Although LoWMob supports a fast intra-PAN handover. it can be supported when the infrastructure node has the location information of the other nodes in the mobile node's moving direction. In this paper, we propose a fast and seamless mobility protocol to support intra-PAN handover, named intra-MARIO. In intra-MARIO, a parent node of the mobile node preconfigures its handover to the PAN when the parent node detects its movement, thereby reducing the handover delay. Since intra-MARIO also supports route optimization, the mobile node can communicate with its corresponding nodes through the optimal route. In this paper, we analysis the signaling cost and evaluates that the handover can be completed in 20ms by simulation.

Efficient Virtual Machine Migration for Mobile Cloud Using PMIPv6 (모바일 클라우드 환경에서 PMIPv6를 이용한 효율적인 가상머신 마이그레이션)

  • Lee, Tae-Hee;Na, Sang-Ho;Lee, Seung-Jin;Kim, Myeong-Eeob;Huh, Eui-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37B no.9
    • /
    • pp.806-813
    • /
    • 2012
  • In a cloud computing environment, various solutions were introduced to provide the service to users such as Infrastructure as a Service (IaaS), Platform as a Service (PaaS), Software as a Service (SaaS) and Desktop as a Service (DaaS). Nowadays, Mobile as a Service (MaaS) to provide the mobility in a cloud environment. In other words, users must have access to data and applications even when they are moving. Thus, to support the mobility to a mobile Thin-Client is the key factor. Related works to support the mobility for mobile devices were Mobile IPv6 and Proxy Mobile IPv6 which showed performance drawbacks such as packet loss during hand-over which could be very critical when collaborating with cloud computing environment. The proposed model in this paper deploys middleware and replica servers to support the data transmission among cloud and PMIPv6 domain. It supports efficient mobility during high-speed movement as well as high-density of mobile nodes in local mobility anchor. In this paper, through performance evaluation, the proposed scheme shows the cost comparison between previous PMIPv6 and verifies its significant efficiency.

A Study on the Concept of the Temporary dwelling space by the composition and use of the mobile Space - FA way of moving, folding, module, extension, evolution by aware of nomad - (모바일 스페이스(Mobile Space)의 공간 구성 및 용법에 의한 일시적 거주 공간 개념에 관한 연구 - 노마드적 인식에 의한 이동, 접이, 모듈, 확장, 진화의 방법으로 -)

  • 김진숙;임종엽
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.5
    • /
    • pp.106-113
    • /
    • 2004
  • The purpose of this study is to present the dwelling space by attaching or inserting the mobile space unit to the fixed building by providing the temporary dwelling space for those suffering from flood disaster, natural disaster or solitary old people or the space and program that the completed building in the city can not provide such as temporary events in the bridge, passage space, walking space for the handicapped, stores located between street blocks, and plaza. Therefore, this study was intended to investigate temporary dwelling space through the composition of space and the experiment of the applicability of the program through the methods of movement, folding, module, expansion and evolution of mobile space. An attempt was made to apply the concept of ‘mobile space’ to the dwelling space not only with a focus on the freedom of variable and changeable physical movement but also with a focus on the existence of the nomad and the way of thinking that bleaks away from a given value system and code, creates a new value and continues to move to a new domain. This study attempted to analyze how the concept of ‘mobile space’ has been developed in what form and method they have been applied and interpreted in the historical background. It attempted to resolve the concepts of movement and mobility through the experiment so that they might apply to the space of contemporary city. This study attempted to experiment this possibility using the mobile space unit and apply it.

A CASE REPORT ABOUT CORRECTION OF IMPLANT POSITION AT HORIZONTAL PLANE AFTER CORTICOTOMY (피질골 절단술을 이용한 수평면에서의 임플란트의 위치 교정에 대한 치험례)

  • Choi, Bin;Oh, Hae-Soo;Kim, Jin-Chul;Kil, Yong-Gab;Kim, Kyoung-Soo;Kim, Jwa-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • Preface: Dental implant is important method that may solve the mastication, occlusion, esthetic, temporomandibular joint, and psychologic problem in oral and maxillofacial surgery. It is ideal that all of the implant are well positioned by adequate technique. By the way it‘s not always possible because of some anatomic, physiologic factor. In this case, If the implant can be moved to adequate position, it may be possible more esthetically and implanted patients more satisfied, but the majority of Implantists and orthodontists have thought that it is not possible. However, Implant, in fact, can be moved. and thus we can overcome the limit of implantation more. The aim of the present study was to evaluate the possibility of implant movement after corticotomy. Case report: Patient missed the upper right first molar. and implantation was done after completion of socket healing. We wait six months for osseointegration. Then, corticotomy was done under local anesthesia and close coil was used for orthodontic force. After traction during 3 weeks, we find the change of implant position at horizontal plane. we can not see the degenerative change on adjacent structure and tracted implant. there is a clinical mobility on upper right second premolar that used for anchorage but it subside spontaneously at the timing of prosthetic restoration without additional treatment. Discussion: As we could have some knowledge with this experiment, we report the case of implant movement after corticotomy and suggest a method about more esthetic implant treatment with a review of literature.

CBT Combustion Precise Modeling and Analysis Using VOF and FSI Methods (VOF와 FSI 방법을 적용한 CBT 연소 정밀 모델링 및 해석)

  • Jeongseok Kang;Jonggeun Park;Hong-Gye Sung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.5
    • /
    • pp.35-43
    • /
    • 2022
  • Precise modeling and analysis of closed bomb test(CBT) combustion using solid propellants was performed. The fluid structure interaction(FSI) method was implemented to analyze the gas and solid phases at the same time. The Eulerian analysis method was applied for the gas phase and grain combustion, and the Lagrangian analysis method was implemented for the grain movement. The interaction between the solid phase grains and the combustion gas was fully coupled through the source term. The volume of fluid(VOF) method was used to simulate the burning distance of the grain and the movement of the combustion surface. The force acting on the grain was comprised of the pressure and gravity acting on the grain burning surface, and the grain burning rate and grain movement speed were considered in the velocity term of the VOF. The combustion analysis was performed for both one and three grains, and fairly compared with the experiments. The acoustic field during grain combustion due to pressure fluctuations was also analyzed.

Segmental Hard Shell Design of Knee Protector for Children Using 3D Printing (3차원 프린팅을 이용한 어린이용 무릎보호대의 분절형 하드쉘 설계)

  • Lee, Hyojeong;Lee, Yejin
    • Journal of Fashion Business
    • /
    • v.21 no.4
    • /
    • pp.116-126
    • /
    • 2017
  • This study applied a segmented hard shell design on knee protectors for children with the objective of increasing mobility. The prototype of the hard shell that does not correspond to movement of the body among components of the knee protector was developed. Surface modeling was conducted based on 3D knee data to enhance comfort through optimized fit on the knee joint where the hard shell would be worn. For this, previous studies on changes in skin near the knee joint during knee flexion were reviewed to establish basic segmental lines. The basic design included six segments, and the number of segments was used as the design variable by increasing or decreasing it to 0, 3, 6, 9, and 14 segments. A prototype was produced from 3D printing with TPU material, worn for wearing assessment. Results revealed fewer numbers of segments resulting in less fit with the body, while actual appearance was stable. Meanwhile, the number of proper segments improved better fit with the body during movement. The wearing assessment revealed the amount of gap reflects change in skin length depending on movement. Assessment results demonstrated basic segment design, S6 with 6 segments, had the best design and most optimized fit. Findings in this study can provide key data for designing knee protection products for children.

The Influence of Scapular-Pelvic Patterns of Proprioceptive Neuromuscular Facilitation on Hemiplegic Gait -A Case Report- (PNF 어깨뼈-골반 패턴이 편마비 환자의 보행에 미치는 영향 -증례보고-)

  • Choi, Jae-Won;Hwang, Sin-Pil
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.27-32
    • /
    • 2018
  • Purpose: This study examined changes in gait speed and stride length after an intervention involving simultaneous scapular and pelvic patterns of proprioceptive neuromuscular facilitation in a hemiplegic patient. Methods: A 58-year-old woman with left hemiplegia who had complained of slowness of gait speed and weakness of leg strength took part in an intervention involving scapular postdepression patterns on the affected side and pelvic postdepression patterns on the nonaffected side. The intervention was performed with the patient lying on her left side, in a half kneeling position, and in a standing posture. Rhythmic initiation was used for teaching the movements to the patient and improvement of kinesthesia, and a combination of isotonic was employed for increasing strength and irradiation of the scapula and pelvic movement. The intervention took place for 30 min. It was implemented twice a day, 5 days a week, for 3 weeks. After three repetitions, the average time taken to complete the 10-m walk test (10 MWT), in addition to stride length, was measured to determine gait speed. Results: After the 3-week program, the patient's performance in the 10 MWT improved from 21.7sec to 17.1sec, and her stride length improved from 31.4cm to 38.7cm. Conclusion: The results showed that trunk movement exercise, especially coordinative movements of the scapula and pelvis can improve gait speed and stride length by increasing trunk stability and mobility. A combination of pelvic and scapular patterns can facilitate trunk rotation, thereby improving gait speed and stride length.