• 제목/요약/키워드: Mobile Stations

검색결과 436건 처리시간 0.025초

위험과 운전 분석을 통한 이동식 수소충전소 안전성 향상에 관한 연구 (A Study on Safety Improvement for Mobile Hydrogen Refueling Station by HAZOP Analysis)

  • 변윤섭
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.299-307
    • /
    • 2021
  • In order to expand the supply of hydrogen vehicles, the first thing to be done is to build an infrastructure to supply hydrogen. There are fixed and mobile types of hydrogen refueling stations that can supply hydrogen. Mobile hydrogen refueling stations have the advantage of supplying hydrogen to two or three areas, so the introduction of mobile hydrogen refueling stations is considered at the initial stage of hydrogen vehicle dissemination. However, mobile hydrogen refueling stations have greater risks than fixed hydrogen refueling stations due to the hazard associated with movement and intensive installation of facilities in vehicle, so stricter design standards to lower the risk must be applied. Therefore, in this study, basic data for establishing safety standards for mobile hydrogen refueling stations were proposed by suggesting improvements such as the location of emergency shutoff valves, the number of gas detectors etc., using HAZOP analysis.

이동릴레이의 추정기반 스캐닝 방안 (An Estimation-Based Scanning Method of Mobile Relay)

  • 이현진;김재현
    • 한국통신학회논문지
    • /
    • 제37A권10호
    • /
    • pp.850-857
    • /
    • 2012
  • Moving network는 고속의 이동체에 설치된 이동릴레이를 통하여 사용자 단말에게 통신서비스를 제공하는 사용 모델이다. 이동릴레이는 핸드오버 과정에서 타겟 기지국을 선택하기 위하여 주기적으로 인접기지국의 신호세기를 측정하며 이동릴레이에 연결된 사용자 단말은 이동릴레이가 측정을 수행하는 동안 서비스의 단절을 경험할 수 있다. 본 논문에서는 이동릴레이의 측정에 의한 사용자 단말의 서비스 단절을 극복하기 위하여 추정 기반의 스캐닝 방안을 제안한다. 제안하는 방안은 이동 릴레이에 종속된 사용자 단말이 핸드오버를 수행하기 위하여 주기적으로 측정한 인접기지국의 수신신호세기를 이용하여 이동릴레이와 인접기지국간의 수신신호세기를 추정하는 것이다. 성능 분석은 신호세기 추정의 정확도, 채널 정보 교환에 따른 오버헤드에 관하여 수행한다. 성능 분석 결과 추정오차는 추정에 사용된 사용자 단말이 6개 이상일 경우 4dBm이내의 정확도를 보였으며 이동릴레이가 직접 스캐닝을 수행하는 방안과 비교했을 때 전송속도가 8Mbps 이상일 경우 제안하는 방안의 오버헤드가 낮은 것을 알 수 있었다.

2 클래스 CDMA 시스템의 성능과 블록킹 확률 (Performance and blocking probability in a two-class CDMA system with mobile station of 2 classes)

  • 김두용;최덕규
    • 한국통신학회논문지
    • /
    • 제21권6호
    • /
    • pp.1501-1509
    • /
    • 1996
  • Mobile stations can be classified by the transmission power level in CDMA system. Different performance parameters will be given to each class of mobile stations so that the appropriate quality ofservices can be provided. In this paper, it is assumed that there are two clsses of mobile stations. with the classification of mobile stations, analytical models are presented for the estimates of the reverse link capacity and the blocking probability. From the model for the reverse link capacity, the maximum number of each class of mobile stations to be served is derived. It is shown that $E_{b/}$I reduction of 1 dB allows the capacity to be increased by 25% and the data transmission rate and the power control accuracy have a significant effect on the reverse link capacity and the blocking probability. Simulation results are provided for validating the anlaytical estimates of the blocking probability.ocking probability.y.

  • PDF

Laws & Regulations concerning Base-Stations for Next-generation Mobile Communication Networks

  • Noh, Sun-Kuk
    • Journal of information and communication convergence engineering
    • /
    • 제2권4호
    • /
    • pp.209-213
    • /
    • 2004
  • With the commercialization of CDMA 2000-1x late in 2000, a high-speed wireless Internet, based on a mobile communication networks, appeared in Korea. This will develop into the next-generation of mobile communications(4G) in the future and the new cell layout will be required the cellular configuration of 4G. We would need the legislation with respect to base-stations and to building the mobile communication networks, as well as the optimization of mobile communication systems. In this study, in order to provide 4G, I examined and analyzed that the current laws & regulations related to licensing and operating a mobile communication base-stations in KOREA.

An Efficient Paging Strategy Based on Paging Agents of Base Stations in Cellular Mobile Networks

  • Suh, Bong-Sue;Choi, Jin-Seek;Choi, Song-In
    • ETRI Journal
    • /
    • 제25권1호
    • /
    • pp.55-58
    • /
    • 2003
  • We propose a new paging strategy to reduce paging cost by adding paging agents at base stations. When a mobile-terminated call occurs, the base stations look up the paging agents to determine if terminal paging is actually to be made. An analytical model based on a Markov chain is used to evaluate the performance of the proposed strategy. The numerical results show that the proposed strategy significantly reduces the paging cost compared with the simultaneous paging strategy.

  • PDF

멀티 홉 릴레이 네트워크에서 간섭을 완화하는 동적 자원 할당 기법 (Dynamic Resource Allocation Scheme for Interference Mitigation in Multi-Hop Relay Networks)

  • 안광훈;김태준
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제5권5호
    • /
    • pp.103-108
    • /
    • 2016
  • 본 논문에서는 멀티 홉 릴레이 네트워크에서 기지국(base station), 중계국(relay station)과 각 단말(mobile station)간의 전송률(throughput)을 향상시킬 수 있는 자원 할당 방법과 간섭을 겪는 단말들의 간섭을 최소화하여 모든 단말의 전송률을 보장하는 방법을 제안하고 있다. 멀티 홉 릴레이 시스템에서 기지국과 릴레이가 주파수 자원을 공유할 수 있으므로 간섭에 취약한 단말들이 생길 수 있다. 본 논문에서는 각 단말의 신호대 잡음 간섭 비(signal to interference plus noise ratio)를 이용하여 엑세스 영역(access zone)과 릴레이 영역(relay zone)의 경계를 동적으로 조절하는 기법과 함께 간섭에 취약한 단말을 분류하고 이를 관리하는 기법을 제안한다. 성능 평가를 통해 제안하는 기법이 무선자원 사용의 효율성을 향상하고 각 단말들의 공평성을 보장하며 네트워크 전체 성능을 향상시키는 것을 확인하였다.

육각형의 셀배치를 가지는 CDMA 이동통신 시스템에서 MSC 간의 소프트 핸드오프를 위한 성능분석 (Performance Analysis for CDMA Soft Handoffs between MSC's under Hexagonal Configuration)

  • 최우용;전치혁
    • 대한산업공학회지
    • /
    • 제30권4호
    • /
    • pp.277-284
    • /
    • 2004
  • CDMA (Code Division Multiple Access) is a promising air interface technique for digital cellular systems. The soft handoff between base stations is one of many important features of CDMA for the mobile stations crossing the cell boundaries. The service areas of MSC's (Mobile Switching Centers) are defined as the unions of the service areas of the base stations connected to MSC's and are assumed to have hexagonal shapes. An analytical approach to the performance analysis of the link between MSC's for supporting the inter-MSC soft handoff scheme will be developed to obtain the probability that a soft handoff to an adjacent MSC will be blocked due to the shortage of the link capacity. Also, the rate of new connection establishments that are requested by the mobile stations moving to the service area of an MSC according to the inter-MSC soft handoff scheme will be obtained.

Hyper-encryption Scheme for Data Confidentiality in Wireless Broadband (WiBro) Networks

  • Hamid, Abdul;Hong, Choong-Seon
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2007년도 춘계학술발표대회
    • /
    • pp.1096-1097
    • /
    • 2007
  • We address the data confidentiality for wireless broadband (WiBro) networks. In WiBro, as the channel is wireless in nature, it suffers from passive and active attack. Passive attack, for example is to decrypt traffic based on statistical analysis and active attack is to modify traffic or inject new traffic from unauthorized mobile stations. Due to high mobility, frequent session key distribution is a bottleneck for the mobile stations. In aspect of WiBro, there is a communication between mobile station to base station, and also in mobile station to mobile station. It is expected to ensure data confidentiality while maintaining minimum overhead for the resource constrained mobile stations. In this paper, we proposed a security framework based on the concept of hyper-encryption to provide data confidentiality for wireless broadband networks.

  • PDF

Performance Evaluation of Vehicle-mounted Mobile Relay in Next Generation Cellular Networks

  • Heo, Keun-Hang;Kang, Hyun-Sik;Moon, Un-Chul;Lee, Jung-Ryun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권5호
    • /
    • pp.874-887
    • /
    • 2011
  • Compared to nomadic and fixed relay stations, vehicle-mounted mobile relay stations show different characteristics caused by the time-variant topology, due to their mobility. Especially, a relay mounted in a vehicle is differentiated from nomadic or fixed relay by the restricted distance between the relay and associated mobile station and the variable density of relay deployment in a cell. In this paper, we identify the characteristics of vehicle-mounted mobile relay stations and provide some parameters that highly influence the performance of vehicle-mounted relay. Through simulation, we measure the effect of relay density, zone ratio, relay transmission power, and frame transmission mode on the performance of vehicle-mounted relay. The results show that the performance of vehicle-mounted relay is highly susceptible to the above vehicle-mounted relay-specific parameters.

Low-cost System with Handheld Analyzer for Optimizing the Position of Indoor Base Stations

  • Lee, C.C.;Xu, Degang;Chan, George
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권2호
    • /
    • pp.404-420
    • /
    • 2021
  • In this paper, an automatic system of locating the indoor area with weak or no mobile signal was proposed and demonstrated experimentally by using the Internet of Things (IoT) technology. Nowadays, the technicians of mobile services providers need to go along with numerous heavy equipment to measure and record the mobile signal strength at outside environment. Recently, there are systems proposed to do such measurement at outdoor area by using the IoT technology automatically. However, these works could not be applied in the indoor area since there are difficulties to do the indoor mapping and positioning. In this work, the Bluetooth Low Energy (BLE) was used to tackle these two difficulties. After a proper placement of BLE in the testing site, while the technician walk around with a handheld analyzer, the data can be obtained accordingly for further analysis in the proposed system which includes the construction of floor plan, detection of mobile signal strength and suggestion of indoor base stations. The gift wrapping and centroid algorithms were used during the analysis. The experimental results showed that the proposed system successfully demonstrated the indoor mapping, positioning of weak mobile signal area and suggestion of indoor base stations for the normal rectangular rooms with an area of 100 m2 on single floor.