• Title/Summary/Keyword: Mixing condition

Search Result 1,057, Processing Time 0.025 seconds

Properties of Sawdust-Rice Husk Mixed Ceramic According to The Rice Husk Mixing Ratios (왕겨의 혼합비율에 따른 톱밥⋅왕겨 혼합세라믹의 성질)

  • Oh, Seung Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.420-427
    • /
    • 2014
  • The physical and mechanical properties of sawdust-rice husk mixed ceramic were investigated with rice husk mixing ratios. The mixed ceramic board was produced with carbonization and resin impregnated sawdust-rice husk board at high temperature. At the same percentage of resin impregnation condition, density and bending strength of the mixed ceramic board increased with increasing the mixing rates of rice husk, whereas weight loss of the ceramic boards decreased. At the same temperature condition for the carbonization of resin impregnated sawdust-rice husk board, the density and bending strength were the highest with 40% of rice husk mixing ratio.

Spray Characteristics of Internal-Mixing Twin-Fluid Atomizer using Sonic Energy (음향에너지를 이용한 내부 혼합형 이유체 분사노즐의 분무특성)

  • Cho, H.K.;Kang, W.S.;Seok, J.K.;Lee, G.S.;Lee, C.W.
    • Journal of ILASS-Korea
    • /
    • v.4 no.3
    • /
    • pp.32-41
    • /
    • 1999
  • In this research, internal-mixing twin-fluid atomizer using sonic energy is designed and manufactured. We are trying to intimate high efficiency twin-fluid atomizer to obtain good liquid atomization in the low pressure region. Define of geometric form of atomizer, characteristics of spray is influenced by position, depth and height variation of cavity resonator, variation of sound intensity and resonant sound frequency with liquid flow rate. The liquid atomization is promoted by multi-stage disintegration of mixing flow of gas with liquid and the optimum condition of position and depth of cavity resonator according to sonic energy is obtained from the condition at a=2.5mm and L=2mm. The velocity distribution of droplets shows negative value due to recirculation region at the center of axial, and as the radial direction distance is far, the velocity distribution of droplets decrease slowly after having a maximum value. However velocity and SMD show nearly uniform distribution at the down stream and as result compared to Nukiyama and Tanasawa's equation. atomization of mixing flow with air and liquid dispersing from the outlet of the nozzle is promoted by the effect of collision at the cavity resonator.

  • PDF

Effect of Plasma Enhancement on the Al-doped ZnO Thin Film Synthesis by MOCVD (유기금속화학기상증착법에 의한 ZnO:Al 필름 합성에서 플라즈마 인가 효과)

  • Seomoon, Kyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.1
    • /
    • pp.33-40
    • /
    • 2019
  • Al-doped ZnO (AZO) thin films were synthesized on Si(100) wafers via plasma enhanced metal organic chemical vapor deposition (PE-MOCVD) method using diethyl zinc (DEZ) and N-methylpyrrolidine alane (MPA) as precursors. Effects of Al/Zn mixing ratio, plasma power on the surface morphology, crystal structure, and electrical property were investigated with SEM, XRD and 4-point probe measurement respectively. Growth rate of the film decreased slightly with increasing the Al/Zn mixing ratio, however electrical property was enhanced and resistivity of the film decreased greatly about 2 orders from $9.5{\times}10^{-1}$ to $8.0{\times}10^{-3}{\Omega}cm$ when the Al/Zn mixing ratio varied from 0 to 9 mol%. XRD analysis showed that the grain size increased with increasing the Al/Zn mixing ratio. Growth rate and electrical property were enhanced in a mild plasma condition. Resistivity of AZO film decreased down to $7.0{\times}10^{-4}{\Omega}cm$ at an indirect plasma of 100 W condition which was enough value to use for the transparent conducting oxide (TCO) material.

The Luminous Efficiency Improvement of Color AC Plasma Display Panel by adding Ar Gas (Ar Gas 첨가에 따른 칼라 플라즈마 디스플레이 패널의 효율 향상)

  • Shin, Jae-Hwa;Choi, Hoon-Young;Lee, Seok-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.3
    • /
    • pp.132-136
    • /
    • 2002
  • In this study, we analyzed the luminous efficiencies of Ne-Xe-Ar and He-Ne-Xe-Ar mixing gas in compared with those of Ne-Xe and He-Ne-Xe mixing gas to improve luminous efficiency by adding a small amount of Ar gas. At the Xe 4%, the brightness of Ne-Xe and He-Ne-Xe mixing gas is higher than others. As the Xe % increases, power consumption decreases. Thus, in the Ne-Xe and He-Ne-Xe mixing gas of Xe 4%, we obtained maxium luminous efficiency. The Ar concentration is varied from 0.1% to 0.7% in this study. The luminous efficiency of the Ne-Xe(4%) mixing gas is improved to 1.16 and 1.13 lm/W by adding an Ar concentration of 0.4% and 0.5%, respectively. The luminous efficiency of the He-Ne-Xe(4%) (He : Ne = 7 : 3) mixing gas is considerably improved by adding an Ar concentration of above 0.3%. The maximum luminous efficiency of this mixing gas is 1.38 lm/W at the condition of adding an Ar concentration of 0.5%.

Effects of mixing/aeration ratio and SRT on nutrient removal in SBR process (연속회분식반응조 공정에서 교반/폭기비와 SRT가 영양염류제거에 미치는 영향)

  • Jeon, Seok-Jun;Kim, Han-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.291-301
    • /
    • 2002
  • In this study, nutrients treatment by sequencing batch reactors(SBR) was performed. Nitrogen and phosphorus removal efficiencies were evaluated by changing SRT and mixing/aeration ratio. Not only nitrogen but also phosphorus removal patterns were investigated through track studies on 1 cycle. As SRT was fixed and mixing/aeration ratio was changed, maximum nitrogen removal efficiency was 87.6% at mixing/aeration ratio 0.67. Phosphorus removal efficiencies were more than 85.5% except no mixing condition. As mixing/aeration ratio was fixed and SRT was changed, nitrogen removal efficiencies were 70.5~79.8%, which represented slight changes, while phosphorus removal efficiencies were 49.0~97.3%, which represented sharply decreasing tendency at less than 20 day. Both phosphorus release rate k and maximum phosphorus release rate $P_{max}/M$ were are decreased as SRT was decreased, but they were not affected by mixing/aeration ratio. It was found that there is a linear relationship between ortho-phosphate uptake and maximum ortho-phosphate release.

Stress evaluation of tubular structures using torsional guided wave mixing

  • Ching-Tai, Ng;Carman, Yeung;Tingyuan, Yin;Liujie, Chen
    • Smart Structures and Systems
    • /
    • v.30 no.6
    • /
    • pp.639-648
    • /
    • 2022
  • This study aims at numerically and experimentally investigating torsional guided wave mixing with weak material nonlinearity under acoustoelastic effect in tubular structures. The acoustoelastic effect on single central frequency guided wave propagation in structures has been well-established. However, the acoustoelastic on guided wave mixing has not been fully explored. This study employs a three-dimensional (3D) finite element (FE) model to simulate the effect of stress on guided wave mixing in tubular structures. The nonlinear strain energy function and theory of incremental deformation are implemented in the 3D FE model to simulate the guided wave mixing with weak material nonlinearity under acoustoelastic effect. Experiments are carried out to measure the nonlinear features, such as combinational harmonics and second harmonics in related to different levels of applied stresses. The experimental results are compared with the 3D FE simulation. The results show that the generation combinational harmonic at sum frequency provides valuable stress information for tubular structures, and also useful for damage diagnosis. The findings of this study provide physical insights into the effect of applied stresses on the combinational harmonic generation due to wave mixing. The results are important for applying the guided wave mixing for in-situ monitoring of structures, which are subjected to different levels of loadings under operational condition.

Analyses of Ocean Discharges Municipal Water and its Near-Field Mixing Characteristics (도시 하수의 해양방류 및 근역혼합특성 분석)

  • 김강만;김지연;이중우
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.243-252
    • /
    • 1999
  • Recently several research groups using CORMIX, approved by EPA, have been working on the hydrodynamic mixing processes due to the ocean discharges. It provides a useful tool for analyzing near field mixing characteristics through the outfall system. This paper applies CORMIX 1 & 2 to the Pusan Jungang Effluent Outfall System, which is planned to be in the Gamchun harbour and will be completed in 2011. This model output shows the trajectoral variation of dilution and concentration for three cases of outfall system. Dilution differences have been simulated and found the highest dilution condition under the different displacement of outfall system. On the basis of these outputs it will be proposed the optimum outfall system type and location. This approach might contribute on protecting the serious water quality problem due to the ocean discharge.

The comparison research of the setting expansion and surface condition by using method of dental stone (치과용 경석고의 사용방법에 따른 경화팽창과 표면상태 비교연구)

  • Park, Soo-chul;Nam, Sang-young;Jung, In-ho
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.263-272
    • /
    • 2016
  • Purpose: The purpose of this study is to measure and compare a degree of setting expansion of dental stone by time depending on the mixing methods and mixing ratios of dental stone, to compare the surface state of each specimen with the use of an optical camera with microscope, and thereby to provide a fundamental material for making dental prostheses. Methods: The test on setting expansion of dental stone is based on ISO 6873. With two different mixing ratios and three kinds of stone mixing methods, test groups were created, and a total of six types of specimens (N=30) were made. Based on the specimens, the setting expansion rate of each one was measured in each time slot of 24 hours, and the surface of the set stone was measured. Results: According to the analysis on setting expansion rate of stone, the setting expansion of the specimen that was created in the way of vacuum mixing at normal mixing ratio was 0.1944% at 120 minutes; the setting expansion of the specimen that was created in the way of vacuum mixing at the mixing ratio which was 40% higher than normal mixing ratio was 0.195% at 120 minutes; the setting expansion of the specimen that was created in the way of mixing with hands at normal mixing ratio and then removing bubbles in vacuum mixer was 0.196% at 120 minutes. Conclusion: The setting expansion rate of each dental stone specimen was significantly different with the lapse of time up to 24 hours(p<.001).

Flow visualization Study on the Turbulent Mixing of Two Fluid Streams(I) (분지관 혼합기의 난류 혼합에 대한 유동 가시화 연구(I))

  • Kim, Gyeong-Cheon;Sin, Dae-Sik;Lee, Bu-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.1
    • /
    • pp.25-33
    • /
    • 1998
  • An experimental study has been carried out to obtain optimal conditions for turbulent mixing of two fluid streams at various angle branches by a flow visualization method. The main purpose of this study is the utilization of flow visualization method as a fast and efficient way to find the optimal mixing conditions when several flow control parameters are superimposed. It is verified that the optimal conditions estimated by flow visualization method have good agreement with the concentration field measurements. The results demonstrate that the diameter ratio is mainly attributed to the mixing phenomena than the branch pipe angle and the Reynolds number. The most striking fact is that there exists the best diameter ratio, d/D.ident. O.17, which requires the minimum momentum ratio in the range of the present experiment. The velocity ratio for the optimal mixing condition has a value within 2 to 16 according to the different flow parameters.

Effect of Swirling Flow by Normal Injection of Secondary Air on the Gas Residence Time and Mixing Characteristics in a Lab-Scale Cold Model Combustor

  • Shin, D.;Park, S.;Jeon, B.;Yu, T.;Hwang, J.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2284-2291
    • /
    • 2006
  • The present study investigates gas residence time and mixing characteristics for various swirl numbers generated by injection of secondary air into a lab-scale cylindrical combustor. Fine dust particles and butane gas were injected into the test chamber to study the gas residence time and mixing characteristics, respectively. The mixing characteristics were evaluated by standard deviation value of trace gas concentration at different measurement points. The measurement points were located 25 mm above the secondary air injection position. The trace gas concentration was detected by a gas analyzer. The gas residence time was estimated by measuring the temporal pressure difference across a filter media where the particles were captured. The swirl number of 20 for secondary air injection angle of 5$^{\circ}$ gave the best condition: long gas residence time and good mixing performance. Numerical calculations were also carried out to study the physical meanings of the experimental results, which showed good agreement with numerical results.