• 제목/요약/키워드: Mixed working fluid

검색결과 26건 처리시간 0.01초

N$_2$와 CF$_4$ 혼합물을 작동유체로 하는 극저온 열사이펀에 대한 실험적 연구 (Experimental Investigation on the Cryogenic Thermosiphon Using N$_2$ and CF$_4$ Mixture as the Working Fluid)

  • 김영권;이지성;정상권;한영희;정세용;박병준
    • 설비공학논문집
    • /
    • 제21권9호
    • /
    • pp.505-512
    • /
    • 2009
  • A thermosiphon is utilized as a thermal shunt to reduce the cool-down time of a cryogenic system cooled by a two stage cryocooler. The cool-down time reduction by the thermosiphon is determined by the type of working fluid which is directly related to the operating temperature range of the thermosiphon. A mixed working fluid has a potential to widen the operation temperature range of the thermosipohon. In this study, the thermosiphon using N$_2$ and CF$_4$ mixture as the working fluid is fabricated and tested to verify its transient heat transfer performance. The thermosiphon with the mixed working fluid has no noticeable reduction of cool-down time compared with that of the thermosiphon with pure working fluid in this experiment. However, it seems that the thermosiphon with mixed working fluid may have an advantage according to the cooling capacity of a cryocooler, the cooling target temperature and the size of a cooling object.

Transparent cryogenic thermosiphon using $N_2\;and\;CF_4$ mixture as the working fluid

  • Lee, Ji-Sung;Jeong, Sang-Kwon;Ko, Jun-Seok;Kim, Young-Kwon;Jung, Se-Yong;Han, Young-Hee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권2호
    • /
    • pp.37-40
    • /
    • 2009
  • A mixed working fluid has a potential to widen the operation temperature range of the thermosiphon. In this study, the thermosiphon using $N_2\;and\;CF_4$ mixture as the working fluid is fabricated and tested to verify its transient thermo hydraulic characteristic. A transparent pyrex glass tube was used for the thermosiphon itself and the vacuum chamber was also fabricated by glass to visualize the internal state of thermo siphon. Onset of condensation temperature was related to the partial pressure of $CF_4$. Two solidifications were observed and condensate temperature range of mixed working fluid was from 160K to 70.7K with $N_2$ 25% composition.

R14와 질소 혼합유체를 사용하는 극저온 열사이펀의 과도상태 거동 (Transient behavior of cryogenic thermosiphon working with R14 and nitrogen mixture)

  • 이지성;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.66-70
    • /
    • 2010
  • The operational temperature range of thermosiphon is generally limited from the critical point to the triple point of the working fluid to maintain two-phase state. Thermosiphon with mixed working fluid has a potential to widen the operational temperature range. In this study, the physical behavior of mixed working fluid during the transient operation of thermosiphon was analyzed with temperature-mole fraction diagram. The condenser and the evaporator temperature variations were explained by the dew line and the bubble line of the mixture. It is encouraging that the thermosiphon operation commences early with larger fraction of high boiling point component, but the temperature gap between the condenser and the evaporator due to the separation of two components has a negative effect on the officient cool down process.

혼합 작동 유체를 이용한 진동 세관형 히트 파이프의 압력 진동과 열전달 특성에 관한 연구 (The Study on Pressure Oscillation and Heat Transfer Characteristics of Oscillating Capillary Tube Heat Pipe Using Mixed Working Fluid)

  • 정현석;김정훈;김주원;김종수
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.318-327
    • /
    • 2002
  • In this paper, heat transfer and pressure oscillation characteristics on oscillating capillary tube heat pipe(OCHP) according to input heat flux, mixture ratio of working fluid and inclination angle were investigated and were compared single working fluid(R-142b) with binary mixture working fluid(R-142b-Ethano1). OCHP was made to serpentine structure of loop type with 10 turns by drilling the channels of length 220mm, width 1.5mm, and depth 1.5mm on the surface of brass plate. In this study, R-l42b and R-l42b-Ethanol were used as working fluids, the charging ratio of working fluids was 40(vol.%), the input heat flux to evaporating section was changed from 0.3W/㎠ to 1.8W/㎠, and mixture ratio of working fluid was R(100%), R(95%)-E(5%), R(90%)-E(10%), and R(85%)-E(15%). From the experimental results, it was found that the effective thermal conductivity of single working fluid was better than that of binary mixture working fluid. But, in case of binary mixture working fluid, critical heat flux was higher than that of single working fluid. And, the higher the mixture ratios of working fluid, the lower heat transfer performance. In case of pressure oscillation, as the inclination angle was lower, pressure wave was more irregular. These phenomena were more serious when the working fluid was binary mixture. Besides, when mixture ratio was higher, saturated pressure was increased, more irregular wave was observed and the mean amplitude was increased. For the same input heat flux, inclination angle and charging ratio, when pressure oscillation has sinusoidal wave, mean amplitude was small, and saturated pressure was low value, the heat transfer was excellent.

미립잠열슬러리의 유체역학적 특성연구 (Fluid dynamical characteristics of microencapsulated phase change material slurries)

  • 이효진;이승우;이재구
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.549-559
    • /
    • 1999
  • An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.

  • PDF

냉열을 이용한 랭킨 사이클 방식의 발전시스템에서 혼합냉매유체 조성비의 적용한계 분석 (A Feasibility Study on the Mixed Refrigerant Composition in the Rankine Cycle Empowered by Cold Energy)

  • 정문;조은비;황인주;강춘형
    • 한국유체기계학회 논문집
    • /
    • 제19권3호
    • /
    • pp.14-18
    • /
    • 2016
  • The power generation system using cold energy, which evolves in a large amount during the vaporization process of the liquefied natural gas, was designed in favor of the Rankine cycle with a mixed refrigerant as the working fluid. In this study it is intended to identify the allowable limits of the working fluid composition in respect of equipment safety in the Rankine cycle-type power generation system driven by the cold energy. The thermodynamic properties of the working fluid, which is a hydrocarbon mixture, were calculated with the Peng-Robinson model. In the steady state simulation of the power generation system by using a commercial tool Aspen HYSYS, the feed conditions of LNG Test Bed Train No.1 along with some necessary assumptions were incorporated. The results indicated that deterioration of the mechanical performance of the equipment as well as its safety would be brought about if contents of $C_2H_6$ and $C_3H_8$ in the mixture become, respectively, too high or too low.

냉매를 작동유체로 사용하는 태양열 난방시스템에 관한 연구 (A study on the solar assisted heating system with refrigerant as working fluid)

  • 김지영;고광수;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.37-44
    • /
    • 2005
  • An experimental study was conducted to analyze performance of a heating system with variation of control logic of the system. The system uses a solar as heat source and composed with heat pump that uses R-22 as working fluid. The difference between the developed system and the commercially available heating system is working fluid. The solar assisted heating system which was widely distributed in the market uses water as a working fluid. It could be freezing in case of the temperature drops down under freezing point. The anti-freezing fluids such as methyl-alcohol or ethylene-glycol are mixed with the water to protect the freezing phenomena. However, the system developed in this study uses a refrigerant as a working fluid. It makes the system to run under zero degree temperature conditions. Another difference of the developed system compare with commercial available one is auxiliary heating method. The developed system has removed an auxiliary electric heater that has been used in conventional solar assisted heating system. Instead of the auxiliary electric heater, an air source heat exchanger which generally used as an evaporator of a heat pump was adapted as a backup heating device of the developed system. As results, an efficiency of the developed system is higher than a solar assisted heat pump with auxiliary electric heater. The merit of the developed system is on the performance increment when the system operates at a lower solar energy climate conditions. In case of the developed system operates at a normal condition, COP of the solar collector driven heat pump is higher than the air source heat exchanger driven heat pump's.

고하중과 고속 미끄럼 베어링 시스템의 경계윤활에 대한 연구 (Study on Boundary Lubrication in the Sliding Bearing System under High Load and Speed)

  • 장시열
    • Tribology and Lubricants
    • /
    • 제15권3호
    • /
    • pp.248-256
    • /
    • 1999
  • Many tribological components in automobile engine undergo high load and sliding speed with thin film thickness. The lubrication characteristics of the components are regarded as ether hydrodynamic lubrication or boundary lubrication, whereas in a working cycle they actually have both characteristics. Many modem engine lubricants have various additives for better performance which make boundary film formation even under hydrodynamic lubrication regime. Conventional Reynolds equation with the viewpoints of continuum mechanics concerns only bulk viscosity of lubricant, which means that its simulation does not give insights on boundary lubrication characteristics. However, many additives of modern engine lubricant provide mixed modes of boundary lubrication characteristics and hydrodynamic lubrication. Especially, high molecular weight polymeric viscosity index improvers form boundary film on the solid surface and cause non-Newtonian fluid effect of shear thinning. This study has performed the investigation about journal bearing system with the mixed concepts of boundary lubrication and hydrodynamic lubrication which happen concurrently in many engine components under the condition of viscosity index improver added.

자동차 조향장치의 트라이볼로지적 고장특성에 관한 사례연구 (Case Study of Tribological Failure Characteristics in Automotive Steering System)

  • 김청균;이일권;조승현
    • Tribology and Lubricants
    • /
    • 제26권1호
    • /
    • pp.61-67
    • /
    • 2010
  • The purpose of this paper is to study and analyze the failure examples on tribological characteristics of an automotive steering system. In this failure study, the grease leakage may stick leaked grease, dust, and wear particles between pinion and rack gears in mechanical steering system. In the case of seal failures such as a rod seal, o-ring and oil seals, the gear box and oil pump do not operate properly due to lack of oils. This means that oil pump does not supply a working fluid and produce a normal oil pressure of the steering system. This leads to leak a working fluid from the seals and produce a wear between pinion and rack gears. Especially, the leaked oil is usually mixed with internal wear particles and foreign dust/fine sands. Thus no leakage of working oils is very important design concepts, which is strongly related to the sealing components and smoothly operating of the mechanical friction parts of power steering system.

산업용 교반기의 고체-액체 혼합에 대한 Eulerian Two-Phase 유동해석 (Eulerian Two-Phase Flow Analysis for Solid-Liquid Mixing in a Industrial Mixer)

  • 송애경;허남건;원찬식;안익진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.471-474
    • /
    • 2006
  • The Mixer is apparatus that help precipitation or an inhomogeneous distribution of various phases to be mixed and that user makes necessary material mixing one or the other. Mainly the mixer which is used from chemical and food industry is very important system in engineering that mixes the material. The inside flow of the mixer under the actual states which put a basis in flow of the fluid is formed rotation of the impeller. The inside flow of impeller will be caused by various reasons change with shape of impeller, number of rotation, mixing material and flow pattern of free surface etc. Also mixer study depended in single-phase flow and experimental research. So the numerical analysis of flow mixing solid-fluid particle is simulated. It is become known, that the case where agitator inside working fluid includes the solid particle the sinkage reverse which the solid particle has decreases an agitation efficiency. From the research which it sees the hazard solid which examines the effect where the change of the sinkage territory which it follows agitation number of revolution and diameter of the particle goes mad to an agitator inside flow distribution - numerical analysis the inside flow distribution of liquid state with Eulerian Two-Phase Method.

  • PDF