• Title/Summary/Keyword: Mixed distribution

Search Result 1,352, Processing Time 0.026 seconds

Determining the Proper Level of Spare Parts using the CSP and (r,Q) Policies in a Two-Echelon Distribution System (2계층 분배시스템에서 혼합재고정책을 이용한 적정재고수준 결정에 관한 연구)

  • Jeong, Suk-Tae;Lee, Jung-Hack;Kim, Kyung-Sup
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.4
    • /
    • pp.121-127
    • /
    • 2007
  • CSP(Concurrent Spare Parts) is supplied with the procurement of new equipment or weapon system and is used to sustain the equipment without resupply during the initial coverage period. This study is concerned with a problem of determining the near optimal inventory level of the spare parts, especially Concurrent Spare Parts. For this, we utilize the mixed periodic and continuous review polices considering the CSP and (r,Q) Policies concurrently in a two-echelon distribution system. We propose the mathematical model to minimize the total cost which is composed with ordering cost, purchasing cost, holding cost, and stickout cost. If the mixed policy is compared to other policies(CSP, (r,Q)), the proposed methodology performs well and is best policy in the equipment maintenance expenses.

Complexes of Polyvalent Metal Ions (Ⅵ). Complexes of Nickel and Cadmium with Dibasic Organic Acids in Aqueous, Ethanol-Water and Acetone-Water Solutions$^*$

  • Sang-Up Choi;Joon-Kil Kang;Young-Il Pae
    • Bulletin of the Korean Chemical Society
    • /
    • v.1 no.2
    • /
    • pp.49-54
    • /
    • 1980
  • Solutions of $Ni^{2+}$ and $Cd^{2+}$ were mixed with the solutions of various dibasic organic acids in the presence of cation exchange resin at room temperature. The distribution ratios of the metal ions between resin and solution were measured, using radioactive metal ions as tracer. From the observed variation of the distribution ratios with acid anion concentrations, it was concluded that $Ni^{2+}$ and $Cd^{2+}$ formed one-to-one complexes with succinate, malonate, o-phthalate and tartarate ions in aqueous, 20 % ethanol-water and 20 % acetone-water solutions. The results of the present study indicated that the relative stabilities of the complexes in solution increased generally in the order : $Ni^{2+}$ < $Cd^{2+}$ complexes. Succinate < malonate < o-phthalate < tartarate complexes. Aqueous < mixed solvent systems.

Sequential Copolypeptides (Ⅲ). Synthesis and Characterization of Poly ($\gamma$-benzyl-L-glutamyl-$\gamma$-benzyl-L-glutamyl-glycine)

  • Choi, Sang-Up;Kang, Joon-Kil
    • Bulletin of the Korean Chemical Society
    • /
    • v.1 no.3
    • /
    • pp.78-82
    • /
    • 1980
  • Solutions of $Cd^{2+}$, $Co^{2+}$ and $Ni^{2+}$ were mixed with the solutions of hydroxycarboxylic acids such as salicylic, lactic and mandelic acids in the presence of cation exchange resin at room temperature. The distribution ratios of the metal ions between resin and solution were measured, using radioactive metal ions as tracer. From the observed variation of the distribution ratios with the acid anion concentrations, it was concluded that $Cd^{2+}$, $Co^{2+}$ and $Ni^{2+}$ formed the one-to-one complexes with salicylate, lactate and mandelate ions in aqueous, 20 % ethanol-water and 20 % acetone-water solutions. The results of the present study indicated that the relative stabilities of the metal-acid complexes in solution increased in the order: $Cd^{2+}$ <$Co^{2+}$ <$Ni^{2+}$ complexes. Salicylate

Estimation of Weibull Lifetimes in Mixed Replacement Model (와이블분포를 따르는 수명시간의 추정)

  • 이태섭
    • Journal of the military operations research society of Korea
    • /
    • v.22 no.2
    • /
    • pp.215-226
    • /
    • 1996
  • The estimation of lifetimes are examined when the distribution of lifetimes are Weibull. It is assumed that, due to physical restrictions and/or economic requirements, the lifetimes are investigated only at certain time intervals during the test period with 'mixed replacement' experiment, even though it is well known that 'with replacement' experiment produces better accuracy than 'without replacement' one. The maximum likelihood estimators are derived through the iterative method like as Lawless(1982). Also Cramer-Rao lower bounds are found as the asymptotic variances of the estimates.

  • PDF

혼합모드 피로균열의 응력재분배 상태 하의 전파거동

  • 이정무;송삼홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.103-103
    • /
    • 2004
  • 실제 작용하는 하중상태는 요소의 형상과 작용하중의 복잡성 때문에 혼합모드 하중상태를 나타낸다. 또한 혼합모드 피로균열은 전파과정 동안 부재의 구속형상이나 외부 작용하중의 급격한 변화에 의해서도 영향 받게 된다. 이로 인하여 피로균열은 균열선단에서 지속적이면서 급격한 응력 재분배의 상태를 경험한다. 그러므로 다양한 응력 재분배 상태에서의 혼합모드 피로균열에 대한 고찰이 필요하다. 본 연구에서는 응력 재분배상태 하에서 나타나는 혼합모드 피로균열의 전파거동에 대한 특징이 실험적으로 고찰되었다.(중략)

  • PDF

A Study on Numerical Analysis of Flow Uniformity According to Length and Degree Change of Mixed-Evaporator in 500 PS SCR Reactor (500 PS SCR 반응기 혼합증발관 길이와 각도 변화에 따른 유동균일도에 대한 수치해석적 연구)

  • Seong, Hongseok;Lee, Chungho;Suh, Jeongse
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.337-342
    • /
    • 2016
  • A marine SCR System is emerging as an alternative to comply with NOx Tier III Emission standards, a restriction on greenhouse gas from vessels implemented by the International Maritime Organization. The system is greatly affected by the uniformity of the fluid flowing into the catalyst, so the performance of the catalyst of an SCR system needs to be guaranteed. This study conducted research on a mixed evaporator of an SCR system, which is one of the factors affecting the uniformity of the fluid. When the angle of the mixed evaporator is set to $90^{\circ}$, the fluid uniformity is at its highest at 83%, under the condition that the length of the mixed evaporator be 3.5 D. When the length was 3.5 D and less, the fluid uniformity had a tendency to improve relative to the case without a bent pipe. However, a longer mixed evaporator results in a more perfect liquidity development in the pipe with a liquidity distribution similar to the case where no curved pipe is formed in front of the catalyst. A lower angle for the mixed evaporator results in a lower flow uniformity, and a longer length of the mixed evaporator results in a lower difference in the flow uniformity caused by the angle. The flow uniformity can be improved by 6% with a mixed evaporator, which confirmed that all factors applied to an SCR system have a close relationship with the efficiency.

Uncertainty Analysis of Parameters of Spatial Statistical Model Using Bayesian Method for Estimating Spatial Distribution of Probability Rainfall (확률강우량의 공간분포추정에 있어서 Bayesian 기법을 이용한 공간통계모델의 매개변수 불확실성 해석)

  • Seo, Young-Min;Park, Ki-Bum;Kim, Sung-Won
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1541-1551
    • /
    • 2011
  • This study applied the Bayesian method for the quantification of the parameter uncertainty of spatial linear mixed model in the estimation of the spatial distribution of probability rainfall. In the application of Bayesian method, the prior sensitivity analysis was implemented by using the priors normally selected in the existing studies which applied the Bayesian method for the puppose of assessing the influence which the selection of the priors of model parameters had on posteriors. As a result, the posteriors of parameters were differently estimated which priors were selected, and then in the case of the prior combination, F-S-E, the sizes of uncertainty intervals were minimum and the modes, means and medians of the posteriors were similar to the estimates using the existing classical methods. From the comparitive analysis between Bayesian and plug-in spatial predictions, we could find that the uncertainty of plug-in prediction could be slightly underestimated than that of Bayesian prediction.

A Study on the Distribution Patterns of Salix gracilistyla and Phragmites japonica Communities according to Micro-landforms and Substrates of the Stream Corridor (하천 미지형 및 하상저질에 따른 갯버들과 달뿌리풀군락의 분포특성에 관한 연구)

  • 전승훈;현진이;최정권
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.2
    • /
    • pp.58-68
    • /
    • 1999
  • This study was carried out to verify the distribution patterns of Salix gracilistyla and Phragmites japonica communities known as obligatory riparian species according to physical factors such as micro-landforms, substrates, etc., at Soo-ip stream corridor. Firstly four vegetation types - Salix gracilistyla dominant type, Phragmites japonica dominant type, mixed type of two species, and mixed type of two species to other species, were classified by cluster analysis based on UPGMA-Euclidean distance. Also these vegetation types showed many different distribution patterns in response to the longitudinal and lateral view along the stream corridor and substrate composition. Salix gracilistyla was major component of dominant vegetation types developed at attack point of bending reach and on substrates composed of rock fragments, but contrastly Phragmites japonica was most important component of dominant vegetation types at point bar of bending reach and floodplain, and on substrates composed of soil materials. Secondly the species and environment biplot form CCA strongly supported the vegetation types divided by classification. Namely Salix gracilistyla was closely correlated with rock fragments and steep slope, which is resistant to physical action even though located near running water. But Phragmites japonica showed a high correlation with soil particles sedimented at floodplain by divergent flow.

  • PDF

A data-driven method for the reliability analysis of a transmission line under wind loads

  • Xing Fu;Wen-Long Du;Gang Li;Zhi-Qian Dong;Hong-Nan Li
    • Steel and Composite Structures
    • /
    • v.52 no.4
    • /
    • pp.461-473
    • /
    • 2024
  • This study focuses on the reliability of a transmission line under wind excitation and evaluates the failure probability using explicit data resources. The data-driven framework for calculating the failure probability of a transmission line subjected to wind loading is presented, and a probabilistic method for estimating the yearly extreme wind speeds in each wind direction is provided to compensate for the incompleteness of meteorological data. Meteorological data from the Xuwen National Weather Station are used to analyze the distribution characteristics of wind speed and wind direction, fitted with the generalized extreme value distribution. Then, the most vulnerable tower is identified to obtain the fragility curves in all wind directions based on uncertainty analysis. Finally, the failure probabilities are calculated based on the presented method. The simulation results reveal that the failure probability of the employed tower increases over time and that the joint probability distribution of the wind speed and wind direction must be considered to avoid overestimating the failure probability. Additionally, the mixed wind climates (synoptic wind and typhoon) have great influence on the estimation of structural failure probability and should be considered.