A study on a digital load cell for the removal of load cell noise (Load Cell Noise 제거를 위한 Digital Load Cell 에 대한 연구)

  • Lee, Young-Jin;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.562-564
    • /
    • 2002
  • Noise reduction and a simplification of a precision measurement system has been performed by changing analog output mode of a load cell into digital output mode. Usually, analog output signal of a few $\mu V$ from a load cell are amplified by amp and acquired by A/D converter. If the distance from a load cell to a DAS(Data Acquisition System) increases, more noise signals are mixed. So, a microprocessor has been integrated into a load cell so that the amplification and A/D conversion of output signals could be done in close proximity to the lode cell for the reduction in mixing of noise. Obtained data from the load cell like this manner are transferred to a computer with digital values(of TTL level). To simplify the configuration of a multi-channel DAS, RS-485 communication system has used for data transfer.

  • PDF

A Technique for Removing Adjacent Induction Noise Mixed with Partial Discharge Signals of High Voltage Rotating Machines (고압 회전기 부분방전 신호에 혼합된 인접상 유도 잡음 제거 기법)

  • Youn, Young-Woo;Yi, Sang-Hwa;Hwang, Don-Ha;Choo, Young-Bae;Kang, Dong-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.335-341
    • /
    • 2009
  • Analysis of the partial discharge signal, a technique to diagnose the stator winding insulation is a key function for the diagnosis of high voltage rotating machines and requires high precision. To satisfy this requirement, various denoising techniques such as filtering and differential methods were proposed. However, these techniques can not eliminate a adjacent induction noise that decreases reliability of the diagnosis. A simple novel denoising algorithm, therefore, is proposed for removing the adjacent induction noise in this paper. The algorithm shows good performance in the real partial discharge signals measured by 13kV class capacitive couplers installed at hydro-generator in Dae-cheong Dam.

A Study on the P Wave Arrival Time Determination Algorithm of Acoustic Emission (AE) Suitable for P Waves with Low Signal-to-Noise Ratios (낮은 신호 대 잡음비 특성을 지닌 탄성파 신호에 적합한 P파 도달시간 결정 알고리즘 연구)

  • Lee, K.S.;Kim, J.S.;Lee, C.S.;Yoon, C.H.;Choi, J.W.
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.349-358
    • /
    • 2011
  • This paper introduces a new P wave arrival time determination algorithm of acoustic emission (AE) suitable to identify P waves with low signal-to-noise ratio generated in rock masses around the high-level radioactive waste disposal repositories. The algorithms adopted for this paper were amplitude threshold picker, Akaike Information Criterion (AIC), two step AIC, and Hinkley criterion. The elastic waves were generated by Pencil Lead Break test on a granite sample, then mixed with white noise to make it difficult to distinguish P wave artificially. The results obtained from amplitude threshold picker, AIC, and Hinkley criterion produced relatively large error due to the low signal-to-noise ratio. On the other hand, two step AIC algorithm provided the correct results regardless of white noise so that the accuracy of source localization was more improved and could be satisfied with the error range.

Design of the Adaptive Filter with Dynamic Structure for the Biomedical Signal Processing (생체신호처리를 위한 동적 구조 적응필터 설계)

  • 이주원;김광열;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.5
    • /
    • pp.848-852
    • /
    • 2001
  • The biomedical signals such as ECG, EMG, EEG, and etc are very Important information to diagnose patients The signal is hard to filter the noise because that is mixed with a lot of noise and biomedical signal has the properties of nonlinear and time-variance. So, we will filter under the measure environment for system or patient. But the general adaptive fillet has brought on the distortion of signal because the adaptive filter adjust the filter coefficient with the fixed order of filter, that filter has the unsuitable order in each other environment. So we propose the dynamic structure adaptive filter that is used for improving that disadvantage. In experiment, we obtain the optimal order of adaptive filter and have food results.

  • PDF

Optimum Design of Natural Observation Filter for Detection of Inflection Point of Time Series Data (시계열 데이터의 변곡점 검출을 위한 자연관측필터의 최적 설계)

  • Kim, Tae-Soo;Chun, Joong-Chang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.635-638
    • /
    • 2005
  • The curve shape of the time fluctuation extracted from the electromagnetic signals is very complex. Thus it is important to decide exactly the signal property such as the inflection point for the observed signal. Usually filters elaborately designed are used to detect the signal characteristics. When the noise is added to the signal, the inflection point can be detected using the observation filter. In this paper we propose the design method for a natural observation filter with optimal filter order to extract a definite inflection point for the case of signals with the mixed noise.

  • PDF

The Optimal Frequency Domain Choice to Measure Partial Discharge in Rotator Machine (회전기 부분방전신호 측정을 위한 최적 주파수 영역 선정)

  • Shin, Hee-Sang;Cho, Sung-Min;Kim, Jae-Chul;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2052-2053
    • /
    • 2007
  • Recently, the importance of supplying the reliable electric power is increasing. Breaking insulation of stator winding is major cause of fault in rotator machine. On-line PD detecting is useful technique to diagnose rotator machine. However, interpretation of its results in time domain is very complex because of the mixed results with PD(Partial Discharge) and noise signal. Therefore, the results were analyzed in frequency domain by FFT (Fast Fourier Transform) to detect precise PD signals. The purpose of this paper is to describe the optimal frequency range to discriminate the PD and noise signal.

  • PDF

Mixed Noise Reduction Filters for CR Images (CR X선 영상의 복합잡음 감소에 관한 연구)

  • Min, Jung-Whan;Jeong, Hea-Won;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • This study is to decrease compound noise in x-ray films. This study compared Signal to noise ratio(SNR), Peak signal to noise ratio(PSNR), Mean square error(MSE) to surface of the earth. In addition, we evaluated noise elimination effect according to the kernel size of Median filter. This experiments show that some filters are useful by finding image that is near in circle image comparing circle picture with each processed picture. In noise power value, when cutoff frequency was compared with other filters of cutoff frequency. Cutoff frequency of $2/3\pi{\sim}3/4\pi$ is good and it shows good SNR and PSNR. Therefore, it can display high filter effect. As Median Filter's Kernel size grows SNR value gets bigger, which shows better filter effect. Most pictures are distorted after filter application in medical treatment image. It is important to keep spatial resolution in most medical images. Visual estimation as well as quantitative indicators should be necessary for a better image.

  • PDF

Modeling of Heart Phantom using the Multidipole Current Source

  • Jang, Kwan-Hee;Yoon, Dal-Hwan;Min, Seung-Gi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1957-1962
    • /
    • 2003
  • In order to design the phantom of heart, we have developed the multi-dipole current source system. Such a one be clue to the various motion of heart. The magnetocardiograph (MCG) system for diagnosing the disease of the heart due to an analysis of the heart signal. The multidipole current source system be built by microprocessor. We use the shield room to obtain a good experimental result. Then the signal acquired is mixed with a background noise, through a filtering extracts a pure signal. The pure signal such a heart phantom is analyzed by an electromagnetic map.

  • PDF

An Excessive Current Subtraction Technique to Improve Dynamic Range for Touch Screen Panel Applications

  • Heo, Sanghyun;Ma, Hyunggun;Bien, Franklin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.3
    • /
    • pp.375-379
    • /
    • 2016
  • A current subtraction technique with parallel operation system is proposed to remove excessive current in touch screen application. The proposed current subtraction remove the current which go into the input node of charge amplifier. The value of subtraction current is same with current when touch screen is not touched. As a result, charge amplifier output is only proportional to variation of mutual capacitor, which make dynamic rage is increased. Also, Transmitter (Tx) driving signal and subtraction driving signal are out of phase each other. Thus, noise generated in Tx is cancelled. The proposed IC is implemented in a mixed-mode 0.18-um CMOS process. Overall system is designed for touch screen panel (TSP) with 16 driving lines and 8 sensing lines. 5-V supply voltages are used in the proposed circuits. For multiple Tx driving signal, Walsh codes are used and signal frequency is 300 khz. By using proposed technique, dynamic rage is improved 36 dB.

AC Arc Detection Method using Mixed Filter and Frequency Analysis (혼합필터와 주파수분석기법을 이용한 교류 아크 검출 기법)

  • Jang, Dong-Uk;Park, Seong-Hee;Lee, Kang-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.200-205
    • /
    • 2017
  • In this paper, we propose a technique to determine the normal and arc of an alternating current using a mixed filter composed of an average filter and a band-pass filter and a frequency analysis. The proposed method uses the moving average filter of the FIR filter structure for noise removal and the band-pass filter of the IIR filter structure for detecting only specific frequency components after normalizing the measured current signal based on the maximum value. After performing Fast Fourier Transform (FFT) using the band-pass filtered signal, the total energy is calculated using the magnitude component of the frequency, and the arc is detected using the magnitude of the calculated energy. In order to show the validity of the proposed method, we experimented with various data and found that arc and steady state can be easily discriminated by calculating spectral energy. Therefore, it is considered that the proposed method can be applied to arc diagnosis of low voltage electric wire.