• Title/Summary/Keyword: Mixed Gases

Search Result 229, Processing Time 0.024 seconds

Am Experimental Study on Measurement of Number Density and Temperature Distributions in $C_3H_8/O_2$ Flame by UV Laser Rayleigh Scattering (UV Laser Rayleigh Scattering을 이용한 $C_3H_8/O_2$ 화염에서 가스 성분의 농도 및 온도 분포 계측에 관한 실험적 연구)

  • Jin, S. H;Nam, G. J.;Kim, H. S.;Chang, N. K.;Park, S. H.;Kim, U.;Park, K. S.;Kim, G. S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.60-68
    • /
    • 1997
  • Rayleigh Scattering Cross Sections($\sigma$i) of various gases and the temperature distributions of premixes C3H8/O2 flame are measured by high power KrF(248nm) Exci- mer laser and ICCD camera. Results show that $\sigma$i of O2 and Propane(C3H8) gases agree well in the 5% error range, but of H2 has the more or less difference from the calcul- ated value by other groups. This is attributed to the low RS signal of H2 to Nosie level(S/N ratio). The temperature distributions of flame range out between 300K in the air and about 2000K in the burned area. In this temperature range, out system has the about 250K temperature resolution. Because low RS signals in the reaction area with high temperature are affected highly by noises, temperature uncertainty of this area is relatively high to another part of flame. Experimental results show that UV Rayleigh Scattering can be used for the measurement of mixing ratio of mixed gases and the temperature distributions of flame. Especially, this technique can be applied for the measurement of the mixing ratio of air/fuel before the ignition and the flame structure after the ignition inside the Engine.

  • PDF

Removal of Mixed Gases of H2S and NH3 by the Biofilter Packed with Biomedia (Biomedia를 충전한 Biofilter에서 H2S와 NH3 혼합악취의 제거)

  • Lim, Joung Soo;Cho, Wook Sang;Lee, Eun Young
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.165-170
    • /
    • 2006
  • When ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) in binary mixture gases were supplied to a biofilter packed with biomedia made of polyurethane, PVA, and worm cast. No odor gases were detected on the outlet of the biofilter when $NH_3$ and $H_2S$ were separately supplied to the biofilter at space velocity(SV) of $50h^{-1}$ until inlet $NH_3$ concentration was increased up to 300 ppmv and inlet $H_2S$ to 428 ppmv. While, inlet $NH_3$ concentration maintained at 50 ppmv, inlet $H_2S$ concentration increased from 1 to 489 ppmv, and the removal efficiency of each gas was investigated. After that, $NH_3$ concentration increased step by step such as 80, 100, 200, 300, 400 and 500 ppmv. $H_2S$ concentration increased gradually when $NH_3$ concentration was set up at each condition. Under each condition, removal efficiency of $NH_3$ and $H_2S$ gas was investigated by analysing the gases sampled from the inlet and outlet of the biofilter. When binary gases were supplied to the biofilter and inlet $NH_3$ concentration was increased from 50 to 300 ppmv, elimination capacity of $NH_3$ increase linearly as inlet loading increased to $11.14g\;N{\cdot}m^{-3}{\cdot}h^{-1}$. However, as inlet $NH_3$ concentration increased over 300 ppmv, both removal efficiency and elimination capacity decreased while inlet loading increased. $H_2S$ removal efficiency was not affected seriously by the simultaneous supply of $NH_3$ when maximum inlet loading of $H_2S$ was under $40.27S{\cdot}m^{-3}{\cdot}h^{-1}$ and maximum inlet loading of $NH_3$ was under $15.25N{\cdot}m^{-3}{\cdot}h^{-1}$.

  • PDF

A Study on the CO2 Removal Efficiency with Aqueous MEA and Blended Solutions in a Vortex Tube Type Absorber (Vortex Tube 형 흡수장치에서 MEA와 혼합흡수용액을 이용한 CO2 제거 효율 고찰)

  • Ryu, Woo-Jung;Han, Keun-Hee;Choi, Won-Kil;Lee, Jong-Sub;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.795-800
    • /
    • 2009
  • In this study, the $CO_2$ removal characteristics of the Vortex tube type absorbtion apparatus were investigated to enhance the compactness of $CO_2$ absorption process and to reduce the amount of absorbing solution of the $CO_2$ separation process. The Vortex tube with the diameter of 17 mm and the length of 250mm was introduced in the experimental apparatus to treat $20Nm^3/hr$ of $CO_2$ containing flue gas. The flue gases for experiments containing 11~13 vol% of $CO_2$ were supplied from the coal-firing CFBC power plant with 12 ton/hr of steam producing capacity. The mixed solutions of 20 wt% of MEA as base solution with the adding solutions like HMDA, AMP and KOH were used as absorbents. The experiments were executed under the various conditions like the absorbing solution concentrations in the range of 20 to 50 wt%, the flow rate of $CO_2$ containing flue gases in the range of 6 to $15Nm^3/hr$ and the flow rate of absorbing solution in the range of 1.0 to 3.0 l/min. As a results, the $CO_2$ removal efficiency of mixed absorbent of 20 wt% of MEA with HMDA was remarkable. From this study, we concluded that the efficient separation of $CO_2$ from flue gases using the features of the Vortex tube type absorbing unit for gas/liquid contact and the separation of gas/liquid be possible. But more works are needed to increase the $CO_2$ removal efficiency of Vortex tube process.

In vitro evaluation of nano zinc oxide (nZnO) on mitigation of gaseous emissions

  • Sarker, Niloy Chandra;Keomanivong, Faithe;Borhan, Md.;Rahman, Shafiqur;Swanson, Kendall
    • Journal of Animal Science and Technology
    • /
    • v.60 no.11
    • /
    • pp.27.1-27.8
    • /
    • 2018
  • Background: Enteric methane ($CH_4$) accounts for about 70% of total $CH_4$ emissions from the ruminant animals. Researchers are exploring ways to mitigate enteric $CH_4$ emissions from ruminants. Recently, nano zinc oxide (nZnO) has shown potential in reducing $CH_4$ and hydrogen sulfide ($H_2S$) production from the liquid manure under anaerobic storage conditions. Four different levels of nZnO and two types of feed were mixed with rumen fluid to investigate the efficacy of nZnO in mitigating gaseous production. Methods: All experiments with four replicates were conducted in batches in 250 mL glass bottles paired with the ANKOM$^{RF}$ wireless gas production monitoring system. Gas production was monitored continuously for 72 h at a constant temperature of $39{\pm}1^{\circ}C$ in a water bath. Headspace gas samples were collected using gas-tight syringes from the Tedlar bags connected to the glass bottles and analyzed for greenhouse gases ($CH_4$ and carbon dioxide-$CO_2$) and $H_2S$ concentrations. $CH_4$ and $CO_2$ gas concentrations were analyzed using an SRI-8610 Gas Chromatograph and $H_2S$ concentrations were measured using a Jerome 631X meter. At the same time, substrate (i.e. mixed rumen fluid+ NP treatment+ feed composite) samples were collected from the glass bottles at the beginning and at the end of an experiment for bacterial counts, and volatile fatty acids (VFAs) analysis. Results: Compared to the control treatment the $H_2S$ and GHGs concentration reduction after 72 h of the tested nZnO levels varied between 4.89 to 53.65%. Additionally, 0.47 to 22.21% microbial population reduction was observed from the applied nZnO treatments. Application of nZnO at a rate of $1000{\mu}g\;g^{-1}$ have exhibited the highest amount of concentration reductions for all three gases and microbial population. Conclusion: Results suggest that both 500 and $1000{\mu}g\;g^{-1}$ nZnO application levels have the potential to reduce GHG and $H_2S$ concentrations.

High Concentration Ozone Generation Characteristics by Variation of Additional Gases and Flow Rates of Inlet Gas (입력가스의 유량변화와 첨가가스에 따른 고농도 오존발생특성)

  • 박승록;이대희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2002
  • There are many effective parameters to high concentration ozone generation. These parameters became very important elements should be considered before designing ozone generator. After designing, there are many peripheral parameters to greatly affect to high concentration ozone generation also. In this study, of many effective peripheral parameters on high concentration ozone generation, the effects of flow rate of inlet oxygen gas and some kinds of additional gases on ozone concentration were investigated As a result, when inlet oxygen gas was introduced at the range of 0.75[LPM]~2.00[LPM] the highest ozone concentration of 71145[ppm] was obtained at 1.25[LPM]. When the additional nitrogen gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest ozone concentration of 73135[ppm] was obtained at 0.8[vol%] of nitrogen gas. This showed 3[%] increasing compared to the case of pure oxygen gas inlet. When the additional argon gas was mixed to oxygen gas at the range of 0.0[vol%]~6.4[vol%] the highest concentration of 67288[ppm]was obtained at 0.8[vol%]of argon gas. This is decreased value compared to that of introducing the pure oxygen.

Comparative Reaction Characteristics of Methane Selective Catalytic Reduction with CO Generation Effect in the N2O Decomposition over Mixed Metal Oxide Catalysts (MMO 촉매 하에서 N2O 분해에 대한 메탄 SCR 반응 및 CO 생성 효과의 비교 연구)

  • Park, Sun Joo;Park, Yong Sung
    • Applied Chemistry for Engineering
    • /
    • v.19 no.6
    • /
    • pp.624-628
    • /
    • 2008
  • Nitrous oxide ($N_2O$), known as one of the major greenhouse gases, is an important component of the earth's atmosphere, and gives rise to precursor of acid rain and photochemical smog. For the removal of $N_2O$ and other nitrogen oxides, the SCR reaction system with various reductants is widely used. This study is based on the results of experimental and theoretical examinations on the catalytic decomposition of sole nitrous oxide ($N_2O$) and selective catalytic reduction of $N_2O$ with $CH_4$ in the presence of oxygen using mixed metal oxide catalysts obtained from hydrolatcite-type precursors. When $CH_4$ is fed together with a reductant, it affects positively on the $N_2O$ decomposition activity. At an optimum ratio of $CH_4$ to $O_2$ mole ratio, the $N_2O$ conversion activity is enhanced on the SCR reaction with partial oxidation of methane.

Development of Primary Reference Gas Mixtures for Liquid Propane (혼합 액체 프로판 표준가스 개발)

  • Jeong, Yun-sung;Kim, Jin-seog;Bae, Hyun-kil;Kang, Ji-hwan;Lee, Seung-ho;Kim, Yong-doo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.49-56
    • /
    • 2021
  • Liquefied Petroleum Gas is divided into liquefied gases containing propane (C3H8) and butane (C4H10). The quality of LPG varies greatly depending on the composition of the mixture, so it is important to measure the composition accurately. It is difficult to determine the composition of the mixture because liquid and gas coexist at room temperature. Therefore, the uncertainty in determining the concentration of hydrocarbons by component is high, and there are many problems that differ from the actual content standard. Therefore, it is necessary to develop a mixed liquid propane standard gas for the composition and accurate concentration of hydrocarbon substances. Mixed liquid propane standard gas is manufactured into bellows-type constant-pressure cylinders by ISO-6142 (2015). The homogeneity of the four standard gases manufactured was confirmed to be GC-FID. The manufacturer's uncertainty of expansion was 0.01 % to 0.30 % and homogeneity was 0.03 % to 0.25 %. In this mixed liquid propane standard gas, the relative expansion uncertainty of weight method, manufacturing consistency, cylinder adsorption and long-term stability was developed within 0.26 %-1.3 9% (95% of confidence level, k=2).

Inductively Coupled Plasma discharge characteristic of Ne, Ar, Kr mixed gas (Ne, Ar, Kr 혼합가스에서의 유도결합형 플라즈마 방전특성)

  • Her, In-Sung;Choi, Yong-Sung;Lee, Chong-Chan;Jeong, Young-Il;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.9-12
    • /
    • 2004
  • Recently, the environmental problem has received considerable attention. so, many lamps have been developing for environmental requirement and energy efficiency. also, at glow discharge lamp researchers try to reduce energy spending that is power saving lamp. this kind requirement agree with strong points of electrodeless fluorescent lamp has received to now lighting sauce. At low pressure as mTorr I.C.P make high density plasma easily, is good to maintain discharge, has high ionization and does not have failing lighting and losing ability of electron radiation by oxidation and volatilization of electrodes, because this tape does not have electrodes This point of I.C.P can use at electrodeless fluorescent lamp in this study ICP display elements and Ar, Ne, Kr are researched for optical characteristic. each gas is looked into optical characteristic, also mixed gases is experiment for optical characteristic.

  • PDF

The Analysis of $SF_6/N_2$ Plasma Properties Under the Atmosphere Pressure ($SF_6/N_2$ 혼합기체의 대기압 플라즈마 특성 분석)

  • So, Soon-Youl;Lee, Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.516-520
    • /
    • 2009
  • Atmosphere Plasmas of Gas Discharge (APGD) have been used in plasma sources for material processing such as etching, deposition, surface modification, etc. This study is to investigate and understand the fundamental plasma discharge properties. Especially, $SF_6/N_2$ mixed gas would be used in power transformer, GIS (Gas insulated switchgear) and so on. In this paper, we developed a one dimensional fluid simulation model with capacitively coupled plasma chamber at the atmosphere pressure (760 [Torr]). 38 kinds of $SF_6/N_2$ plasma particles which are an electron, two positive ions (${SF_5}^+$, ${N_2}^+$), five negative ions (${SF_6}^-$, ${SF_5}^-$, ${SF_4}^-$, ${F_2}^-$, ${F_1}^-$), thirty excitation and vibrational particles for $N_2$ were considered in this computation. The $N_2$ gases of 20%, 50%, 80% were mixed in $SF_6$ gas. As the amount of $N_2$ gas was increased, the properties of electro-negative plasma moved toward the electro-positive plasma.

Thin and Hermetic Packaging Process for Flat Panel Display Application

  • Kim, Young-Cho;Jeong, Jin-Wook;Lee, Duck-Jung;Choi, Won-Do;Lee, Sang-Geun;Ju, Byeong-Kwon
    • Journal of Information Display
    • /
    • v.3 no.1
    • /
    • pp.11-16
    • /
    • 2002
  • This paper presents a study on the tubeless Plasma Display Panel (PDP) packaging using glass-to-glass electrostatic bonding with intermediate amorphous silicon. The bonded sample sealing the mixed gas with three species showed high strength ranging from 2.5 MPa to 4 MPa. The glass-to-glass bonding for packaging was performed at a low temperature of $180^{\circ}C$ by applying bias of 250 $V_{dc}$ in ambient of mixed gases of He-Ne(27 %)-Xe(3 %). The tubeless packaging was accomplished by bonding the support glass plate of $30mm{\times}50mm$ on the rear glass panel and the capping glass of $20mm{\times}20mm$. The 4-inch color AC-PDP with thickness of 8 mm was successfully fabricated and fully emitted as white color at a firing voltage of 190V.