• Title/Summary/Keyword: Mirror-image

Search Result 382, Processing Time 0.029 seconds

Realization of Infrared Thermograph System (적외선 체열촬영시스템의 구현)

  • 이수열;우응제;조민형
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.13-24
    • /
    • 1994
  • In the conventional thermograph systems, expensive infrared lens systems are usually used for accomodating infrared beams to high speed optical scanners. In this study, a cheap focussing mirror with a two dimensional scanner are used for the development of medical infrared thermograph system in which high speed imaging is not critically required. The infrared thermograph system can be used for two dimensional imaging of human skin temperature by measuring the amount of infrared lights radiating from it. It has been experimentally proven that the accuracy of temperature measurements using the developed system is under 0.1$^{\circ}C$ with image matrix size of 256${\times}$240, and imaging time of 4 seconds.

  • PDF

Laser scanning unit with plastic f$\theta$ lenses featuring high resolution (600DPI용 플라스틱 f$\theta$렌즈가 실장된 Laser Scanning Unit 의 측정 및 평가)

  • 임천석
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.364-368
    • /
    • 1999
  • We investigate the evaluation items of LSU (Laser Scanning Unit), such as beam size, f$\theta$ characteristics, linearity, skew and bow, optical power ratio between image height of 0mm and $\pm$108 mm, pitch error, Jitter and shift of printing position. Through the measurement of LSU using BSH (Beam Scan Head) installed on LMC (Linear Motion Controller) which moves linearly within the whole scanning range (-108 mm~+108 mm), we can ascertain plastic f$\theta$ lenses, which are manufactured by TVLP (Two-step Variable Low Pressure) molding method, to satisfy 600DPI(Dots Per Inch) performance.

  • PDF

Occluded Object Motion Estimation System based on Particle Filter with 3D Reconstruction

  • Ko, Kwang-Eun;Park, Jun-Heong;Park, Seung-Min;Kim, Jun-Yeup;Sim, Kwee-Bo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.12 no.1
    • /
    • pp.60-65
    • /
    • 2012
  • This paper presents a method for occluded object based motion estimation and tracking system in dynamic image sequences using particle filter with 3D reconstruction. A unique characteristic of this study is its ability to cope with partial occlusion based continuous motion estimation using particle filter inspired from the mirror neuron system in human brain. To update a prior knowledge about the shape or motion of objects, firstly, fundamental 3D reconstruction based occlusion tracing method is applied and object landmarks are determined. And optical flow based motion vector is estimated from the movement of the landmarks. When arbitrary partial occlusions are occurred, the continuous motion of the hidden parts of object can be estimated by particle filter with optical flow. The resistance of the resulting estimation to partial occlusions enables the more accurate detection and handling of more severe occlusions.

Auto-guiding System for CQUEAN

  • Kim, Eun-Bin;Park, Won-Kee;Jeong, Hyeon-Ju;Kim, Jin-Young;Kim, Dong-Han;Kim, Han-Guen;Kuehne, John;Odoms, Peter S.;Choi, Chang-Su;Im, Myung-Shin;Pak, Soo-Jong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.61.2-61.2
    • /
    • 2010
  • CQUEAN (Camera for Quasars in EArly uNiverse) is an optical CCD camera system which has its own auto-guiding system. Guiding system consists of a 1k*1k CCD camera, FLI PL1001E, a flat mirror to feed the image of an off-axis field to the camera and baffle. The whole system lies on a moving arm which rotates 90 degree effectively to enlarge the field of view. A motor, IMS MDRIVE 34, and a differential decelerator, APEX AD140-050, are used for the moving mechanism. Auto-guiding is controlled by Agdr program. We had a first light from Aug. 10 to Aug 17, 2010 at McDonald Observatory, USA. In this presentation, we describe about the auto-guiding system for CQUEAN and its performance on the 2.1m telescope.

  • PDF

Tomographic Interpretations of Visible Emissions from the Axisymmetric Partially Premixed Flames (단층진단법을 이용한 축대칭 부분예혼합 화염의 자발광 스펙트럼 해석에 관한 연구)

  • Ha, Kwang-Soon;Choi, Sang-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.769-776
    • /
    • 2000
  • Visible spectral characteristics of cross-sectional emissions from a partially premixed methane/air and propane/air flames have been investigated. An optical train with a two-axis scanning mirror system was used to record line-of-sight emission spectra from 354nm to 618nm, and inversion technique was adapted to obtain cross-sectional emission spectra. By analyzing the reconstructed emission spectra, cross-sectional intensities of CH and $C_2$ radicals were separated from the background emissions. The blue flame edge and yellow flame edge were also obtained by image processing technique for edge detection with color photograph of flame. These edges were compared with radial distributions of CH, $C_2$ radicals and background emissions. The CH radicals were observed at blue flame edge. The background emissions were generated by soot precursor at upstream of flame and by soot at downstream of flame. The $C_2$ radicals in propane/air flame were observed more than those in methane/air flame.

Design of Interactive Teleprompter (인터렉티브 텔레프롬프터의 설계)

  • Park, Yuni;Park, Taejung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.43-51
    • /
    • 2016
  • This paper presents the concept of "interactive teleprompter", which provides the user with interaction with oneself or other users for live television broadcasts or smart mirrors. In such interactive applications, eye contacts between the user and the regenerated image or between the user and other persons are important in handling psychological processes or non-verbal communications. Unfortunately, it is not straightforward to address the eye contact issues with conventional combination of normal display and video camera. To address this problem, we propose an "interactive" teleprompter enhanced from conventional teleprompter devices. Our interactive teleprompter can recognize the user's gestures by applying infra-red (IR) depth sensor. This paper also presents test results for a beam splitter which plays a critical role for teleprompter and is designed to handle both visual light for RGB camera and IR for Depth sensor effectively.

Development of Grading and Sorting System of Dried Oak Mushrooms via Color Computer Vision System (컬러 컴퓨터시각에 의거한 건표고 등급 선별시스템 개발)

  • Kim, S.C.;Choi, D.Y.;Choi, S.;Hwang, H.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.130-135
    • /
    • 2007
  • An on-line real time grading and sorting system for dried oak mushrooms was developed for on-site application. Quality grades of the mushrooms were determined according to an industrial specification. Three dimensional visual quality features were used for the grading. A progressive color computer vision system with white LED illumination was implemented to develop an algorithm to extract external quality patterns of the dried oak mushrooms. Cap (top) and gil (stem) surface images were acquired sequentially and side image was obtained using mirror. Algorithms for extracting size, roundness, pattern and color of the cap, thickness, color of the gil and amount of rolled edge of the dried mushroom were developed. Utilizing those quality factors normal and abnormal ones were classified and normal mushrooms were further classified into 30 different grades. The sorting device was developed using microprocessor controlled electro-pneumatic system with stainless buckets. Grading accuracy was around 97% and processing time was 0.4 s in average.

Color balancing of the half-mirror-based stereo image by using SURF algorithm (SURF 알고리즘을 이용한 직교식 스테레오 카메라 영상의 칼라 불균형 보정 방법)

  • Li, Ruei-Hung;Shin, Hyoungchul;Sohn, Kwanghoon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.133-136
    • /
    • 2011
  • 본 논문에서는 SURF 알고리즘을 이용한 직교식 스테레오 카메라 영상의 칼라 불균형 보정 방법 제안한다. 제안 방법에서는 SURF 알고리즘을 이용하여 스테레오 좌, 우 영상의 대응점을 찾은 후, 찾은 대응점들의 칼라 보정 벡터를 영상 획득 모델을 기반으로 계산한다. 영상 전체에서 다양한 칼라 대응점 정보를 추출하기 위하여 본 논문에서는 분할영상을 이용하여 칼라 대응점 정보를 추출한다. 추출된 대응점 정보는 초기 칼라 보정 벡터로 변환할 수 있으며 좌, 우 영상의 모든 픽셀에 대하여 색정보가 가장 유사한 대응점의 보정 벡터를 사용하여 칼라 불균형을 보정한다. 초기 보정 벡터를 이용한 칼라 불균형 보정 후 존재하는 노이즈을 제거하기 위하여 유사한 색공간에 위치한 칼라 보정 벡터에 가우시안 필터를 적용한다. 실험 결과로 원본 영상과 보정된 영상의 칼라 히스토그램을 비교하였으며, 분할 영역의 수에 따른 보정 결과도 비교 제시하였다. 실험 결과는 제안한 방법이 직교식 스테레오 카메라 영상에 효과적인 칼라 불균형 보정 방법임을 보여준다.

  • PDF

An Application of Dynamic Radioscopy Technique to Static Firing Test (동적 방사선투과검사를 이용한 지상연소시험 기술개발)

  • Lim, Soo-Yong;Kim, Jun-Yeop;Kim, In-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.32-40
    • /
    • 2006
  • Dynamic Radioscopy technique was developed to observe internal phenomena of motors during firings. For use of this technique, generator and image box consisting of conversion screen, mirror, and video camera were designed and fabricated at our laboratory, and static firing tests were conducted to small motors. Protection devices against vibration and noise induced from during combustion were also made and their performances were evaluated with reference to the vibration criteria. Test results have shown that the vibration levels at concerned points were measured less than vibration criteria, and the internal phenomena during firings were also observed clearly.

Development of Non-contact Image Measuring Technique for Evaluating Micro-relief (미세주름 측정을 위한 비접촉식 영상측정기술의 발전)

  • Kim, Nam-Soo;Kim, Yong-Min
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.253-257
    • /
    • 2005
  • Assurance of the objectivity and reproducibility is a major key point in wrinkle measurement used for evaluating the degree of skin aging. The measurement of relief is quickly converted to a non-contact method, of which tools or instruments do not come in contact with skin directly, to minimize the artificial effects which influence the shape or depth of the relief. Here, we showed how wrinkle measurement techniques have been changed briefly and compared PRIMOS and replica method in the point of view of measurement principle and features, the former is non-contact fringe projection tool and the latter is contact type of the method.