• 제목/요약/키워드: Minimum power line

검색결과 144건 처리시간 0.036초

Training an Artificial Neural Network for Estimating the Power Flow State

  • Sedaghati, Alireza
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.275-280
    • /
    • 2005
  • The principal context of this research is the approach to an artificial neural network algorithm which solves multivariable nonlinear equation systems by estimating the state of line power flow. First a dynamical neural network with feedback is used to find the minimum value of the objective function at each iteration of the state estimator algorithm. In second step a two-layer neural network structures is derived to implement all of the different matrix-vector products that arise in neural network state estimator analysis. For hardware requirements, as they relate to the total number of internal connections, the architecture developed here preserves in its structure the pronounced sparsity of power networks for which state the estimator analysis is to be carried out. A principal feature of the architecture is that the computing time overheads in solution are independent of the dimensions or structure of the equation system. It is here where the ultrahigh-speed of massively parallel computing in neural networks can offer major practical benefit.

  • PDF

A Possible Path per Link CBR Algorithm for Interference Avoidance in MPLS Networks

  • Sa-Ngiamsak, Wisitsak;Varakulsiripunth, Ruttikorn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.772-776
    • /
    • 2004
  • This paper proposes an interference avoidance approach for Constraint-Based Routing (CBR) algorithm in the Multi-Protocol Label Switching (MPLS) network. The MPLS network itself has a capability of integrating among any layer-3 protocols and any layer-2 protocols of the OSI model. It is based on the label switching technology, which is fast and flexible switching technique using pre-defined Label Switching Paths (LSPs). The MPLS network is a solution for the Traffic Engineering(TE), Quality of Service (QoS), Virtual Private Network (VPN), and Constraint-Based Routing (CBR) issues. According to the MPLS CBR, routing performance requirements are capability for on-line routing, high network throughput, high network utilization, high network scalability, fast rerouting performance, low percentage of call-setup request blocking, and low calculation complexity. There are many previously proposed algorithms such as minimum hop (MH) algorithm, widest shortest path (WSP) algorithm, and minimum interference routing algorithm (MIRA). The MIRA algorithm is currently seemed to be the best solution for the MPLS routing problem in case of selecting a path with minimum interference level. It achieves lower call-setup request blocking, lower interference level, higher network utilization and higher network throughput. However, it suffers from routing calculation complexity which makes it difficult to real task implementation. In this paper, there are three objectives for routing algorithm design, which are minimizing interference levels with other source-destination node pairs, minimizing resource usage by selecting a minimum hop path first, and reducing calculation complexity. The proposed CBR algorithm is based on power factor calculation of total amount of possible path per link and the residual bandwidth in the network. A path with high power factor should be considered as minimum interference path and should be selected for path setup. With the proposed algorithm, all of the three objectives are attained and the approach of selection of a high power factor path could minimize interference level among all source-destination node pairs. The approach of selection of a shortest path from many equal power factor paths approach could minimize the usage of network resource. Then the network has higher resource reservation for future call-setup request. Moreover, the calculation of possible path per link (or interference level indicator) is run only whenever the network topology has been changed. Hence, this approach could reduce routing calculation complexity. The simulation results show that the proposed algorithm has good performance over high network utilization, low call-setup blocking percentage and low routing computation complexity.

  • PDF

Flyback AC-DC Converter with Low THD Based on Primary-Side Control

  • Chang, Changyuan;He, Luyang;Cao, Zixuan;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1642-1649
    • /
    • 2018
  • A single-stage flyback LED AC-DC converter based on primary-side control under constant current mode is proposed in this study. The proposed converter features low total harmonic distortion (THD) and high power factor (PF). It also consists of a zero-crossing distortion compensation circuit and a variable duty ratio control compensation circuit to deal with the line current distortions caused by fixed duty ratio control. The system model and layout are built in Simplis and Cadence, respectively. The feasibility and performance of the proposed circuit is verified by designing and fabricating an IC controller in the HHNEC $0.35{\mu}m$ 5 V/40 V HVCMOS process. Experimental results show that the PF can reach a level in the range of 0.985-0.9965. Moreover, the average THD of the entire system is approximately 10%, with the minimum being 6.305%, as the input line voltage changes from 85 VAC to 265 VAC.

Blazed 격자 구조형 방향성 결합기의 광학 특성 (Optical Characteristics of Blazed Grating-Assisted Directional Coupler)

  • 호광춘
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권5호
    • /
    • pp.175-180
    • /
    • 2019
  • 새로운 고유치 문제에 기초한 모드 전송선로 이론 (Modal Transmission-Line Theory: MTLT))을 이용하여 blazed 격자 구조형 방향성 결합기 (B-GADC)의 광학 특성과 채널사이의 전력전달을 자세하게 분석하였다. 설계한 B-GADC의 결함효율을 분석하기 위하여 격자주기와 파장에 따라 변하는 quasi-TE 모드와 quasi-TM 모드의 분산곡선을 수치 해석하였으며, blazing 특성이 GADC의 결합효율에 미치는 영향을 분석하기 위하여 대칭형, 톱니형 그리고 비대칭형 blazed 격자구조를 설계하고 평가하였다. 수치해석 결과, blazed 격자구조가 대칭형에서 비대칭형으로 변함에 따라 최대 전력전송을 위한 최소 간격 조건을 만족하는 격자주기는 줄어들었으며 결합길이는 반대로 늘어나는 것을 확인하였다.

배전자동화시스템의 효율적인 운용을 위한 구가기능 및 정보전송체계 (The Additional Functions and Data Transmission Flow Diagram for Effective Operation of Distribution Automation System)

  • 이중호;하복남;조남훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.211-213
    • /
    • 1998
  • This paper introduces the additional remote monitoring and remote setting functions needed to operate the distribution automation system effectively. we compare the additional functions with the old functions. The remote setting of minimum trip value of fault indicator is an example of additional function. It saves time and line-man's power. Also this paper describes the data transmission flow diagram for operation of distribution automation system using wireless communication method.

  • PDF

YBCO film을 이용한 저항형 초전도 한류기의 전류제한 특성 (Current limiting characteristics of the resistive SFCL using YBCO film)

  • 최효삼;김혜림;황시돌;현옥배;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.277-280
    • /
    • 1999
  • We fabricated a resistive superconducting fault current limiter of two stripe meander type based on a YBCO film, and performed current limitation experiments. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. At $0^{\circ}$ fault angle the minimum quench current was $9.6 A_{peak}$(meander line cross section: $5{\times}10^{-6}cm^2$) and the fast quench time was 0.63 msec. The resistance of the limiter continued to increase for three cycles due to heat generation in the gold layer and was stabilized afterwards. At $45^{\circ}$ and $90^{\circ}$ the fast quench time were 0.56 msec and 0.26 msec, respectively. The quench time is believed to be reduced because faults occurred when the current was increasing or was at the peak value. With the limiter we could effectively limit the fault current about 1/5 times right after the fault and about 1/8.5 times three cycles after.

  • PDF

Mixed Lubrication Analysis of Cam/Tappet Interface on the Direct Acting Type Valvetrain System

  • Cho, Myung-Rae;Shin, Heung-Ju;Han, Dong-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제15권6호
    • /
    • pp.685-692
    • /
    • 2001
  • This paper reports on the mixed lubrication characteristics between the cam and the tappet contact surface of direct acting type valve train systems. First, the dynamic characteristics are solved by using the lumped mass method to determine the load conditions at the contact point. Then, the minimum oil film thickness is calculated with consideration of elastohydrodynamic line contact theory and the friction force is obtained by using the mixed lubrication model which separates the hydrodynamic and the boundary friction. Finally, the average surface temperatures are calculated by using the flash temperature theory. The results show that, there are some peaks in the friction force due to the asperity contact friction, and flash temperature at the position of minimum oil film thickness. It is thought that there is a relationship between the surface temperature and cam surface wear, and therefore, the analysis on the worn cam profile has been performed.

  • PDF

유압 베인 펌프에서의 탄성유체윤활 해석 (Elastohydrodynamic Lubrication Analysis in Hydraulic Vane Pump)

  • 박태조
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권3호
    • /
    • pp.7-13
    • /
    • 2013
  • Hydraulic vane pumps are widely used in various hydraulic systems because of its compactness and light weight. It is well known that the vanes and cam ring are separated by very thin liquid films which result in the EHL state. Contrary to the case of cylindrical roller bearings, the inlet and side boundary pressures are much higher than the atmospheric pressure. In this paper, a numerical solution of the EHL of finite line contacts between the cam ring and vane tip with profiled ends is presented. Using a finite difference method with non-uniform grids and the Newton-Raphson method, converged solutions are obtained for moderate load and material parameters. The EHL pressure distribution and film shape are considerably affected by pump delivery pressure and the side boundary condition applied. Both the maximum pressure and the minimum film thickness always occurred near the edge regions. The present results can be used in the design of optimum vane profile in hydraulic vane pump.

선로용량한계를 고려한 단기 발전계획 (Short-Term Generation Scheduling Considering Transmission Line Capacity Limits)

  • 김준현;송현선;유인근
    • 대한전기학회논문지
    • /
    • 제35권12호
    • /
    • pp.594-602
    • /
    • 1986
  • This paper proposes an effective algorithm for short-term generation scheduling for the purpose of economic and secure operation of thermal power systems. Especially, in the procedure of solution by Dynamic Programming, Linear Programming is introduced to promote the possibility of optimal solution and the security of power systems, and evaluation of security function is improved by the application of seven step approximation of normal distribution. Several necessary considerations, that is, time dependent start-up and constant down cost of generating units, demand and spinning reserve constraints, minimum up and sown time constraints, the number of possible start-up of a generating unit in a d and the number of generating units which can be started up at the same time at the same bus, are also incoporated to elevate the usability and flexibility of the algorithm. Finally, the effectiveness of the proposed algorithm has been demonstrated by applying to the 6-gen. 21-bus model power system.

  • PDF

양양 양수 발전기의 계통 운전시 무효전력 운전범위와 OEL 동특성 시험 (Tests on the Reactive Power Limit and the OEL Dynamics of Yang-Yang P/P in Operation)

  • 김동준;문영환;한종렬;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.384-386
    • /
    • 2006
  • This paper deals with tests on the reactive power output limit and the Over-Excitation Limiter (OEL) dynamics of generation unit. The suggested reactive limit test methods can identify the allowable maximum/minimum reactive power at 100% rated MW in the steady-state operation condition. The on-line OEL limit test method can identify the time characteristics of OEL with the generation output at 50% of the rated MW. These methods are validated by applying to Yang-Yang Pumped storage units of 282 MVA.

  • PDF