• Title/Summary/Keyword: Minimum detectable activity

Search Result 58, Processing Time 0.028 seconds

Induction of Apoptotic Cell Death in Human Jurkat T Cells by a Chlorophyll Derivative (Cp-D) Isolated from Actinidia arguta Planchon

  • Park, Youn-Hee;Chun, En-Mi;Bae, Myung-Ae;Seu, Young-Bae;Song, Kyung-Sik;Kim, Young-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2000
  • The chloroform and methanol (2;1, v/v) extract from an edible plant, Actinidia arguta Planchon, appeared to possess antitumor activity against human leukemias Jurkat T and U937 cells through inducing apoptosis. The substance in the solvent extract was purified by silica gel column chromatography, preparative TLC, and Sephadex LH-20 column chromatography. Characteristics of the substance analyzed by UV scanning analysis, $^1H$ and $^{13}C$ NMR spectra suggested that the substance belongs to the chlorophyll derivatives-like group. The $IC_{50}$ value of the chlorophyll derivative (Cp-D) determined by MTT assay was $15\mu\textrm{g}/ml$ for Jurkat, $10\mu\textrm{g}/ml$ for U937, and $11.4\mu\textrm{g}/ml$ for HL-60m and was more toxic to these leukemias than to solid tumors or normal fibroblast. In order to elucidate cellular mechanisms underlying the cytotoxicity, the effect of the Cp-D on Jurkat T cells was investigated. When cells were treated with the Cp-D at a concentration of $15\mu\textrm{g}/ml$, [3H]thymidine incorporation declined rapidly and wa undetectable in 1h. However, no significant changes were made in the cell cycle distribution of the cells by 24h. The sub-Gl peak representing apoptotic cells began to be detectable in 36h, at which time apoptotic DNA fragmentation was also detected on agarose gel electrophoresis, demonstrating that the cytotoxic effect of the Cp-D is attributable to the induced apoptosis. Under the same conditions, although the protein level of cyclin-dependent kinases such as cdc4, csk6, cdk2, and cdc2 was not significantly changed until 24h, the kinase activity of all c안 rapidly declined and reached a minimum level within 1-6h and then recovered to the initial level by 12h and sustained until 24h. These results suggest that inactivation of cdks at an inappropriate time during the cell cycle progression in jurkat T cells following a treatment with the Cp-D leads to induction of apoptotic cell death.

  • PDF

Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

  • Yoon, Yoon Yeol;Kim, Yongcheol
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.142-146
    • /
    • 2020
  • Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial. Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analysis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs. Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was approximately 3.60 ± 0.29 cpm when the 145-mL vial was used and 2.22 ± 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial. Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.

Survey of radioactive contamination in imported foodstuffs (수입 식품중의 방사능 오염실태 조사)

  • Lee, Wan-No;Lee, Haeng-Pil;Chung, Kun-Ho;Kim, Hee-Reyoung;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo;Chung, Hyung-Wook;Lee, Eun-Ju;Sho, You-Sup;Lee, Jong-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.141-148
    • /
    • 2006
  • Surveys of radioactive contamination were performed for imported foodstuffs in 2003. The following samples among imported foodstuffs were selected from markets and Korea Food and Drug Administration(KFDA); the imported samples from country associated with the Chernobyl nuclear accident, the samples produced around the nuclear power plants or nuclear tests, the foodstuffs reported as radioacitive contamination materials in foreign country. After pretreatments such as drying and homogenization, samples were analyzed. The $^{137}Cs$ radionuclide was only measured among the regulation radionuclides($^{137}Cs,\;^{134}Cs,\;^{131}I$) of food code. All foodstuffs except Inonotus Obliquus(Chaga mushooms) are less than 17.0 Bq/kg or below the minimum detectable activity(MDA). The activity concentrations of Chaga mushrooms from Russia ranged up to 131.25 Bq/ltg which is almost 35 % of the maximum permitted level of food code. The fraction of imported foodstuffs having meaningful radioactivity is small, however, the radioactive contamination survey of imported foodstuffs is still needed.

ASSOCIATION OF INFRARED DARK CLOUD CORES WITH YSOS: STARLESS OR STARRED IRDC CORES

  • Kim, Gwan-Jeong;Lee, Chang-Won;Kim, Jong-Soo;Lee, Youn-Gung;Ballesteros-Paredes, Javier;Myers, Philip C.;Kurtz, S.
    • Journal of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.9-23
    • /
    • 2010
  • In this paper we examined the association of Infrared Dark Cloud (IRDC) cores with YSOs and the geometric properties of the IRDC cores. For this study a total of 13,650 IRDC cores were collected mainly from the catalogs of the IRDC cores published from other studies and partially from our catalog of IRDC cores containing new 789 IRDC core candidates. The YSO candidates were searched for using the GLIMPSE, MSX, and IRAS point sources by the shape of their SED or using activity of water or methanol maser. The association of the IRDC cores with these YSOs was checked by their line-of-sight coincidence within the dimension of the IRDC core. This work found that a total of 4,110 IRDC cores have YSO candidates while 9,540 IRDC cores have no indication of the existence of YSOs. Considering the 12,200 IRDC cores within the GLIMPSE survey region for which the YSO candidates were determined with better sensitivity, we found that 4,098 IRDC cores (34%) have at least one YSO candidate and 1,072 cores among them seem to have embedded YSOs, while the rest 8,102 (66%) have no YSO candidate. Therefore, the ratio of [N(IRDC core with protostars)]/[N(IRDC core without YSO)] for 12,200 IRDC cores is about 0.13. Taking into account this ratio and typical lifetime of high-mass embedded YSOs, we suggest that the IRDC cores would spend about $10^4\sim10^5$ years to form high-mass stars. However, we should note that the GLIMPSE point sources have a minimum detectable luminosity of about $1.2 L_{\odot}$ at a typical IRDC core's distance of ~4 kpc. Therefore, the ratio given here should be a 100ver limit and the estimated lifetime of starless IRDC cores can be an upper limit. The physical parameters of the IRDC cores somewhat vary depending on how many YSO candidates the IRDC cores contain. The IRDC cores with more YSOs tend to be larger, more elongated, and have better darkness contrast than the IRDC cores with fewer or no YSOs.

Study of the determination of 226Ra in soil using liquid scintillation counter (액체섬광계수기를 이용한 토양 중 226Ra 분석 방법 연구)

  • Jung, Yoonhee;Kim, Hyuncheol;Chung, Kun Ho;Kang, Mun Ja
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.65-72
    • /
    • 2016
  • This study presented an analytical method for detecting radium in soils using a liquid scintillation counter (LSC). The isotope 226Ra was extracted from soil using the fusion method and then separated from interfering radionuclides using the precipitation method. Radium was coprecipitated as sulfate salts with barium (Ba) and then converted into Ba(Ra)CO3, which is soluble in an acidic solution. The isotope 222Rn, the decay progeny of 226Ra, was trapped in a water immiscible cocktail and analyzed by LSC. The pulse shape analysis (PSA) level was estimated using 90Sr and 226Ra standard solutions. The figure of merit was the highest at PSA 80, while the alpha spillover was the lowest at PSA 80. The counting efficiency was 243 ± 2% in a glass vial. This analytical method was verified with International Atomic Energy Agency (IAEA) reference materials, including IAEA-312, IAEA-314, and IAEA-315. The recovery ranged from 60–82%, while the relative bias between the measured value and the recommended value was less than 10%. The minimum detectable activity was 2.1 Bq kg−1 with dry mass 1 g, the background count rate of 0.02 cpm, the recovery rate of 70% and counting time of 30 min.

Bioequivalence of Azela Tablet to Azeptin Tablet (Azelastine Hydrochloride 1 mg) (아젭틴 정(염산아젤라스틴 1 mg)에 대한 아젤라 정의 생물학적 동등성)

  • Cho, Hea-Young;Yun, Ji-Hun;Seo, Yu-Lee;Oh, In-Joon;Lee, Sung-Kwan;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.1
    • /
    • pp.57-62
    • /
    • 2001
  • Azelastine, a phthalazinone derivative, is an antiallergic agent which demonstrates histamine $H_1-receptor$ antagonist activity and also inhibits histamine release from mast cells following antigen and non-antigen stimuli. Thus, azelastine may be useful in the management of both asthma and allergic disorders. The purpose of the present study was to evaluate the bioequivalence of two azelastine hydrochloride tablets, $Azeptin^{TM}$ (Bu Kwang Pharmaceutical Co., Ltd.) and $Azela^{TM}$ (Kyung Dong Pharmaceutical Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). Eighteen normal male volunteers, $22.44{\pm}2.01$ years in age and $61.99{\pm}6.18\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After two tablets containing 1 mg of azelastine hydrochloride per tablet were orally administered, blood was taken at predetermined time intervals and the concentrations of azelastine in serum were determined using HPLC with fluorescence detector. Pharmacokinetic parameters such as $AUC_t$, $C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters. The results showed that the differences in $AUC_t$, $C_{max}\;and\;T_{max}$ between two tablets were -6.45%, -2.60% and -7.14%, respectively, when calculated against the $Azeptin^{TM}$ tablet. The powers $(1-{\beta})$ for $AUC_t\;and\;C_{max}$ were 96.65% and 88.47%, respectively. Minimum detectable differences $({\Delta})$ at ${\alpha}=0.05$ and $1-{\beta}=0.8$ were less than 20% (e.g., 14.40% and 17.65% for $AUC_t\;and\;C_{max}$, respectively). The 90% confidence intervals were within ${\pm}20%$ (e.g., $-14.87{\sim}1.97$ and $-12.92{\sim}7.72$ for $AUC_t\;and\;C_{max}$, respectively). Two parameters met the criteria of KFDA for bioequivalence, indicating that $Azela^{TM]$ tablet is bioequivalent to $Azeptin^{TM}$ tablet.

  • PDF

Study on the Fatigue Crack Behavior by the Stress Intensity Factor and AE Parameters (응력확대계수와 음향방출 변수를 이용한 피로균열 거동 연구)

  • Yoon, Dong-Jin;Jeong, Jung-Chae;Park, Phi-Lip;Kim, Ki-Bok;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.412-423
    • /
    • 2000
  • By using the relation between stress intensity factor and AE parameter, new approach method for assessing the crack length and detectability of crack was proposed. Laboratory experiment was carried out to identify AE characteristics of fatigue cracks for compact tension specimen. The relationship between a stress intensity factor and AE signals activity as well as conventional AE parameter analysis was discussed. As a result, the features of specific parameter such as the length of crack growth the AE energy, the AE peak amplitude, and the cumulative AE hits, showed the almost same trend in their increase as the number of fatigue cycle increased. From the comparisons of peak amplitude and AE energy with stress intensity factor, it was verified that the higher stress intensity factors generated AE signals with higher peak amplitude and a larger number of AE counts. If we can get more reliable database for the relation between AE parameters and stress intensity factor, this approach will provide a good information for evaluating both the existence of crack and the minimum detectable size of crack.

  • PDF

A Rapid Method for the Measurement of $^{222}Rn$ in Groundwater and Hot Spring Water using Ultra Low-Level Liquid Scintillation Counter and Pulse Shape Analysis (극저준위 액체섬광계수기와 파형분석법을 이용한 지하수 및 온천수중 $^{222}Rn$의 신속측정법)

  • Kim, Chang-Kyu;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.103-115
    • /
    • 1995
  • For the determination of $^{222}Rn$ in water by a very simple and time saving liquid scintillation counting method that does not require any chemical separation, an optimum analytical condition has been investigated. The optimum pulse shape analysis(PSA) level for the measurement of $^{222}Rn$ using LKB 1220 Quantulus liquid scintillation counter was 110 for Optiphase HiSafe3 cocktail and 90 for toluene-based cocktail. The counting efficiencies of $^{222}Rn$ in the window covering u spectra using Optiphase HiSafe3 cocktail were 282.2% for glass vial and 271.6% for Teflon vial, whereas the counting efficiencies in toluene-based cocktail were 262.3% and 247.5% for glass and Teflon vials, respectively. The minimum detectable activity(MDA) in the u window for a 60-min measurement with a Teflon vial using Optiphase HiSafe3 cocktail was $0.30Bq/{\iota}$. The analytical method studied from this work was also applied to the determination of $^{222}Rn$ in some groundwater and hot spring water samples.

  • PDF

Bioequivalence of Tigrin Capsule to Disgren Capsule (Triflusal 300 mg) (디스그렌 캅셀(트리플루살 300 mg)에 대한 티그린 캅셀의 생물학적 동등성)

  • Kim, Soo-Jin;Shim, Young-Sun;Son, Sun-Mi;Lim, Dong-Koo;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.4
    • /
    • pp.355-360
    • /
    • 1999
  • Triflusal is a new antithrombotic agent which inhibits both platelet cyclooxygenase and c-AMP phosphodiesterase activity. The purpose of the present study was to evaluate the bioequivalence of two triflusal capsules, $Disgren^{TM}$ (Myung-In Pharmaceutical Co., Ltd.) and $Tigriri^{TM}$ (Hana Pharmaceutical Co., Ltd.) according to the guidelines of Korea Food and Drug Administration (KFDA). Eighteen normal male volunteers, $22.94{\pm}1.83$ in age and $63.7l{\pm}10.43$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one capsule containing 300 mg of triflusal was orally administered, blood was taken at predetermined time intervals and the concentrations of triflusal in serum were determined using HPLC method with UV detector. Pharmacokinetic parameters such as $AUC_t$ $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters. The results showed that the differences in $AUC_t$ $C_{max}$ and $T_{max}$ between two capsules were -0.30%, 0.81 % and -3.03%, respectively when calculated against the $Disgren_{TM}$ capsule. The powers $(1-{\beta})$ for $AUC_t$ $C_{max}$ and $T_{max}$ were 98.29%,84.73% and 81.02%, respectively. Minimum detectable differences $({\Delta})$ at ${\alpha}=0.1$ and $1-{\beta}=0.8$ were all less than 20% (e.g., 12.91%, 18.46% and 19.65% for $AUC_t$ $C_{max}$ and $T_{max}$ respectively). The 90% confid,ence intervals were all within ${\pm}20%$(e.g., $-8.97{\sim}8.37$, $-11.58{\sim}13.22$ and $-16.23{\sim}10.17$ for $AUC_t$ $C_{max}$ and $T_{max}$, respectively). All of the above parameters ($1-{\beta}, {\Delta}$ and 90% confidence intervals) met the criteria of KFDA for bioequivalence, indicating that $Tigriri^{TM}$ capsule is bioequivalent to $Disgren^{TM}$ capsule.

  • PDF

A Study on the Variation of Rn-222 Concentration in Groundwater at Busan-Geumjeong area (부산 금정구지역의 지하수에 포함된 라돈농도 변화 연구)

  • Cho, Jungg-Sook;Lee, Hyo-Min;Kim, Sun-Woong;Kim, Jin-Seop
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.149-158
    • /
    • 2012
  • In this paper, we measured the variations of radon concentrations in groundwater using low-level Liquid Scintillation Counter (LSC), an instrument for analyzing the alpha and beta radionuclides at its 10 sites around the Kumjung-Gu, north-western of Busan. Optimization of Pulse Shape Analyzer (PSA) to determinate the highest value of figure of merit (FM) was decided using Quantulus 1200 LSC with radium-226 source, the optimal PSA level was shown in the range of 100 to 110. The results show that the Minimum Detectable Activity (MDA) of radon concentrations is 0.61 $Bq{\cdot}L^{-1}$ for 20 minutes in PSA level. We find that the average radon concentration in groundwater is high in granitic rock area and low in volcanic rock area. (Biotite granite : 191.39 $Bq{\cdot}L^{-1}$, Micro graphic granite : 141.88 $Bq{\cdot}L^{-1}$, Adamellite : 92.94 $Bq{\cdot}L^{-1}$, Andesite (volcanic) : 35.35 $Bq{\cdot}L^{-1}$). No significant seasonal variation pattern is observed from the long-term variation analysis from 10 selected sites. We have not seen the significant correlation of radon concentration to groundwater temperature, atmospheric temperature, atmospheric pressure and rainfall. The concentration variation is probably caused by more complex factors and processes.