• 제목/요약/키워드: Minimum Unit

검색결과 653건 처리시간 0.023초

A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

  • 울라 우바이드;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권4호
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

Chill Unit 축적과 휴면해제시기 공간변이 추정 프로그램 : CUMAP (CUMAP : A Chill Unit Calculator for Spatial Estimation of Dormancy Release Date in Complex Terrain)

  • 김광수;정유란;윤진일
    • 한국농림기상학회지
    • /
    • 제6권3호
    • /
    • pp.177-182
    • /
    • 2004
  • 기온의 공간변이가 심한 넓은 지역에서 Chill Unit 축적량과 휴면해제일의 공간분포를 얻기 위해서 Utah Chill Unit 모형을 지리정보시스템과 결합하여 Chill Unit 공간적산기(CUMAP)을 개발하였다. CUMAP은 Grid 형태의 일 최고, 최저기온을 입력받아 시간내삽법에 의해 매시기온을 추정하고, Utah 모형에 의해 매시 Chill Unit을 계산한다. 하루 단위로 Chill Unit이 누적되면 Grid파일로 저장되며, 사용자가 정하는 저온요구량(임계값)에 도달하는 날짜를 역시 Grid파일로 생성한다. 전라북도 김제시 백구면 일대 포도재배지역에 대해 CUMAP을 적용하여 10m 해상도의 Chill Unit 일별 적산값과 휴면해제일 추정분포도를 작성하였다.

복합기능을 수용하는 소규모 및 극소규모 미술관의 단위전시공간 구성에 관한 연구 (A Study on the Composition of the Exhibition space unit in the Minimum Art Museum and Small Art Museum Admitting Multifunction)

  • 문정민;안우진;고성룡
    • 한국실내디자인학회논문집
    • /
    • 제29호
    • /
    • pp.181-187
    • /
    • 2001
  • The art museum plays a role as a cultural space that can solve the cultural desire of people and see a good art works. It is in exhibition space that they personally exchange the feeling between an art work and a viewer in art museum. The types and works - a fiber, a photo, an establishment that needs many places, devices, a video art, and an action art called "performance", cultural art - are shown in small art museum. Moreover, exhibition spaces are modified into the space of another art activities like dancing, music concerts in small art museum because it has no profit space for diverse art activities. And the exhibition the characters of the exhibition space in small art museum. So, it needs to change the characters of the exhibition space in small art museum. Under these background, this stud\ulcorner surveys and analyzes the exhibits, the organization methods, the modified conditions, and the scale of the existing exhibitional space in small art museum. Therefore, the goal of this study is to suggest the composition of the exhibition space unit considering the function and the multifunction in minimum art museum and small art museum.

  • PDF

중환자실 병상주변공간의 면적과 간격에 관한 연구 (A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

Bounded QEA 기반의 발전기 기동정지계획 연구 (A Thermal Unit Commitment Approach based on a Bounded Quantum Evolutionary Algorithm)

  • 장세환;정윤원;김욱;박종배;신중린
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1057-1064
    • /
    • 2009
  • This paper introduces a new approach based on a quantum-inspired evolutionary algorithm (QEA) to solve unit commitment (UC) problems. The UC problem is a complicated nonlinear and mixed-integer combinatorial optimization problem with heavy constraints. This paper proposes a bounded quantum evolutionary algorithm (BQEA) to effectively solve the UC problems. The proposed BQEA adopts both the bounded rotation gate, which is simplified and improved to prevent premature convergence and increase the global search ability, and the increasing rotation angle approach to improve the search performance of the conventional QEA. Furthermore, it includes heuristic-based constraint treatment techniques to deal with the minimum up/down time and spinning reserve constraints in the UC problems. Since the excessive spinning reserve can incur high operation costs, the unit de-commitment strategy is also introduced to improve the solution quality. To demonstrate the performance of the proposed BQEA, it is applied to the large-scale power systems of up to 100-unit with 24-hour demand.

인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구 (Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

병렬 적응 진화알고리즘을 이용한 발전기 기동정지계획에 관한 연구 (A Parallel Adaptive Evolutionary Algorithm for Thermal Unit Commitment)

  • 김형수;조덕환;문경준;이화석;박준호;황기현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권9호
    • /
    • pp.365-375
    • /
    • 2006
  • This paper is presented by the application of parallel adaptive evolutionary algorithm(PAEA) to search an optimal solution of a thermal unit commitment problem. The adaptive evolutionary algorithm(AEA) takes the merits of both a genetic algorithm(GA) and an evolution strategy(ES) in an adaptive manner to use the global search capability of GA and the local search capability of ES. To reduce the execution time of AEA, the developed algorithm is implemented on an parallel computer which is composed of 16 processors. To handle the constraints efficiently and to apply to Parallel adaptive evolutionary algorithm(PAEA), the states of thermal unit are represented by means of real-valued strings that display continuous terms of on/off state of generating units and are involved in their minimum up and down time constraints. And the violation of other constraints are handled by repairing operator. The procedure is applied to the $10{\sim}100$ thermal unit systems, and the results show capabilities of the PAEA.

전력저장장치를 고려한 일간 최적 기동정지계획 수립연구 (Daily Unit Commitment Scheduling of Power System with Energy Storage System)

  • 송하나;장세환;김형중;노재형;박종배
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.717-725
    • /
    • 2011
  • In the power system with an electric storage system that can increase utilization rate of the source of such new renewable energy, this paper introduces the approach on the daily unit commitment scheduling that determines simultaneously optimum operational condition and output of thermal generators and electric storage device. The unit commitment is one of the most important issues in economic operation and security of short-term operational plan of the power system. It is to determine on/off status of generator to minimize operational cost during the given period. The committed generator should satisfy various operational limitation such as estimated demand by system, spinning reserve condition within minimum operational cost. In order to determine on/off or charge/discharge/idle condition and output level of units and electric storage system, the MILP(Mixed Integer Linear Programming) is suggested. The proposed approach is the mixed method between LP(Linear Programming) and IP(integer programming) which seeks the value of real number and integer that maximize or minimize function objective within given condition. The daily unit commitment problem with the electric storage system is applied to MILP algorithm through linearization and formulation process. The proposed approach is applied to the test system.

퍼셉트론형 신경회로망에 의한 패리티판별 (Parity Discrimination by Perceptron Neural Network)

  • 최재승
    • 한국정보통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.565-571
    • /
    • 2010
  • 본 논문에서는 퍼셉트론형 신경회로망에 오차역전파 알고리즘을 사용하여 학습을 실시하여, N비트의 패리티판별에 필요한 최소의 중간유닛수의 해석에 관한 연구이다. 따라서 본 논문은 제안한 퍼셉트론형 신경회로망의 중간 유닛의 수를 변화시켜 N비트의 패리티 판별 실험을 실시하였다. 본 시스템은 패라티 판별의 실험을 통하여 N비트 패리티 판별이 가능하다는 것을 실험으로 확인한다.

소비자 요구를 반영한 아파트 보조주방 모듈 개발에 고한 연구 (A Study on the planning of the Sub-kitchen Module Meeting Consumer Needs for the Apartment Unit Plan)

  • 방희조
    • 한국실내디자인학회논문집
    • /
    • 제21권1호
    • /
    • pp.170-176
    • /
    • 2012
  • Korean living culture raised the users' needs for sub-kitchen. In the traditional Korean house, there was large space related to kitchen area for preparing food and stock big and bulky housing stuffs. As apartment housing became dominant as Korean dwelling, sub-kitchen has been planed in the balcony that is not included in the sales area. In this study, the case of the apartment housing in Esiapolis, Daegu was analyzed. To plan the user-oriented sub-kitchen, the consumer research was carried out. Consumers needed a pantry, more storage near the kitchen, and wanted to place washing machine and washing stand in a sub-kitchen. Sub-kitchens were planed to meet those consumers' needs. Through this case study and former studies analysis, sub-kitchen's function unit was derived: wash, storage, auxiliary work. By combining each function unit, sub-kitchen was classified into 3 types, wash & auxiliary work, wash & storage, and wash & storage & auxiliary work. For each sub-kitchen type, components of function units, available layouts, and minimum size were recommended.

  • PDF