• 제목/요약/키워드: Minimum Phase

검색결과 930건 처리시간 0.038초

근접쌍성 AG PERSEI의 광전관측과 근성점 운동 분석 (PHOTOELECTRIC OBSERVATIONS OF CLOSE BINARY AG PERSEI AND ITS APSIDAL MOTION ANALYSIS)

  • 이강환;정장해
    • Journal of Astronomy and Space Sciences
    • /
    • 제13권1호
    • /
    • pp.63-71
    • /
    • 1996
  • A total of 546 UBV photoelectric observations of AG Per was carried out from January to December in 1993 at Chungbuk National University Observatory. With our observations, UBV light curves were constructed, three minimum times of JDHel. 2449284.213, JDHel. 2449360.060, and JDHel. 2449363.192 were determined. The phase displacement of secondary minimum time $\delta$=-0.046 were determined and orbital eccentricity e=0.071 was calculated. Forty-five times of minimum light (including ours) were collected from the literature and plotted on O-C diagram. We analyzed these data and apsidal motion period of U=76.17 (years) was obtained. Using e and U for AG Per, the internal structure constant, log k2, was found to be -2.13.

  • PDF

Design of Multi-winding Inductor for Minimum Inductor Current Ripple Using Optimized Coupling Factor

  • Kang, Taewon;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.231-232
    • /
    • 2016
  • This paper investigates the design of multi-winding coupled inductor for minimum inductor current ripple. Based on the general circuit model of coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor of n-phase multi-winding coupled inductor which corresponds to a minimum inductor ripple current becomes -(1/n-1), i.e. a complete inverse coupling without leakage inductance, as the duty ratio of steady-state operating point approaches 1/n, 2/n, ${\cdots}$ or (n-1)/n. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the duty ratio of steady-state operating point approaches either zero or one. Therefore, coupled inductors having optimal coupling factor can minimize the ripple current of inductor and inductor size.

  • PDF

반응표면법과 유한요소법을 이용한 라인-스타트 영구 자석 전동기의 최대토크밀도와 최소전류밀도을 위한 최적설계 (Optimum Design Criteria for Maximum Torque Density & Minimum Current Density of a Line-Start Permanent-Magnet Motor using Response Surface Methodology & Finite Element Method)

  • 장순명;전명진;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1055-1056
    • /
    • 2011
  • This paper deals with optimum design criteria for maximum torque density & minimum current density of a single phase line-start permanent-magnet motor (LSPMM) using RSM (Response Surface Methodology) & FEM (Finite Element Method). The focus of this paper is to find a design solution through the comparison of torque density and minimum current density resulting from rotor shape variations. And then, a central composite design (CCD) mixed resolution is introduced, and analysis of variance (ANOVA) is conducted to determine the significance of the fitted regression model.

  • PDF

두 대의 로봇의 근사 최소시간 제어를 위한 충돌회피 궤적 계획 (Near-Minimum Time Trajectory Planning of Two Robots with Collision Avoidance)

  • 이동수;정낙영;서일홍;최동훈;유준
    • 대한기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1495-1502
    • /
    • 1991
  • 본 연구에서는 동일 작업 공간내에서 두대의 로봇이 각각의 토크의 제한 조건 과 충돌 회피 조건을 만족하면서 근사 최소 시간에 지정된 경로를 주행하기 위한 궤적 계획법을 제안하고자 한다. 이때, 동작 우선도에 의하여 한 대의 로봇은 주 로봇, 다른 한 대의 로봇은 종 로봇으로 지정되는데 주 로봇은 입력 토크의 제한조건을 만족 하며 주어진 경로를 최소 시간에 움직이도록 궤적 계획을 하였으며, 종 로봇은 주 로 봇과의 충돌을 피하고 입력 토크의 제한 조건을 만족하며 주어진 경로를 근사 최소 시 간에 움직이도록 하였다.

Gas/Particle Level and Dry Deposition Flux of Atmospheric PCBs

  • Yeo, Hyun-Gu;Park, Ki-Chul
    • 한국환경보건학회지
    • /
    • 제29권4호
    • /
    • pp.10-16
    • /
    • 2003
  • Atmospheric samples were conducted from September 2001 to July 2002 with GPS-l PUF sampler in rural site to concentration distributions of gas/particle PCBs and to calculate dry deposition flux of PCBs. $\Sigma$PCBs concentrations of gas/particle PCBs were 59.29$\pm$48.83, 6.56$\pm$6.59 pg/㎥, respectively. Gas contribution (%) of total PCBs (gas + particle) was 90% which existed gas phase in the atmosphere. The particle contribution (%) of PCB congeners increased relatively more of the less volatile congeners with the highest chlorine number. The correlation coefficients (r) between total PCBs and temperature ($^{\circ}C$) showed negative correlation in - 0.62 (p<0.0l) for particle phase, positive correlation in 0.63 (p<0.01) for gas phase. In other word, particle phase PCBs is enriched in colder weather which could be due to greater in corporation of condensed gas phase at low temperature. The calculated dry deposition of total PCBs (gas + particle) was 0.008, 0.008 $\mu\textrm{g}$ $m^{-2}$ da $y^{-l}$ which showed maximum dry deposition flux in December, minimum data in July Bs in the atmosphere. The calculated dry deposition fluxes of total PCBs were influenced by particle phase PCBs even though PCBs in the atmosphere were present primarily in the gas phase.e.

MQAM, DPSK, OFDM-MQAM과 OFDM-DPSK의 위상 잡음 영향 연구 (Phase Noise Influence on SER of MQAM, DPSK, OFDM-MQAM, OFDM-DPSK)

  • 권요안;김인석
    • 한국전자파학회논문지
    • /
    • 제18권2호
    • /
    • pp.219-226
    • /
    • 2007
  • 본 논문에서는 DPSK(Quadrature Phase Shift Keying), MQAM(M-ary quadrature Amplitude Modulation), OFDM(Orthogonal Frequency Division Multiplex)-MQAM, OFDM-DPSK 변조 방식에 대한 SER(Symbol Error Rate)을 위상 잡음에 대한 영향을 정량적으로 도출하였다. 시뮬레이션(MATLAB)을 이용하여 위상 잡음이 없는 이상적인 경우와 비교하였으며, 또한 상기 변조 방식에 대하여 심벌 레이트와 변조 대역폭간의 비에 따른 위상 잡음 영향을 분석하였고, 각 변조에서 요구되는 최소 위상 잡음 조건을 제시하고 도출하였다.

Ferroelectric Phase Transition of Lead Free (1-x)(Na0.5K0.5)NbO3-xLiNbO3 Ceramics

  • Park, Jong-Ho;Park, Hui-Jin;Choi, Byung-Chun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권6호
    • /
    • pp.297-300
    • /
    • 2012
  • Lead-free (1-x)$(Na_{0.5}K_{0.5})NbO_3-xLiNbO_3$, i.e., NKN-LNx (x=0.0, 0.1, 0.2, 0.3, 0.4 mol) was prepared using the conventional solid state reaction method. The effects of LN mixing on the ferroelectric properties of NKN-LNx ceramics were studied using a dielectric constant and P-E (Polarization-electric field) measurements. Ferroelectricity was observed in the composition for x approximately varying between 0.0 and 0.4. Minimum remanent polarization $2P_r=5C/cm^2$ was achieved in the composition for x = 0.2. The ferroelectric phase transition temperature $T_C$ increased with increasing LN content. The ferroelectric phase transition of NKN-LNx ($x{\geq}0.1$) is a second-order phase transition, and that of NKN-LNx ($x{\leq}0.2$) is a first-order phase transition. These results indicate that the ferroelectric phase transition temperature of NKN-LNx change from that of second-order to weak first-order phase transition according to the LN content.

단상전원에 접속된 3상 유도전동기의 손실분석 (Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source)

  • 김도진;좌종근
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.

구조적 불확실성을 갖는 비최소위상계의 강인한 제어기 설계 (Design of a robust controller for nonminimum phase system with structured uncertainty)

  • 김신구;서광식;김영철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.422-425
    • /
    • 1997
  • We consider the robust control problem for nonminimum phase(NMP) systems with parametric uncertainty which appear often in aircraft and missile control. First, a new method that makes such an uncertain NMP system to be factored as a interval minimum phase(MP) transfer function and a time delay term in the Pade approximation form has been presented. The controller to be proposed consists of a compensator $C_{Q}$(s) with Smith predictor in the internal model control(IMC) structure, so that it can have good robustness and performance against the structured uncertainty and the time delay behaviour due to NMP plant the $C_{Q}$(s) is designed on the MP model by using QFT. The stability and performance of overall system has been evaluated by the generalized Kharitonov theorem.rem.

  • PDF

염수 축냉이 김치냉장고의 성능에 미치는 영향 (A Study on the Effects of the Cold Heat Storage with Salt Water on the Performance of a Kimchi Refrigerator)

  • 길복임;최은수
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.891-896
    • /
    • 2010
  • The objective of the present study is to reveal the effects of a phase-change material on the performance of a Kimchi refrigerator. Two-percent salt water, of which melting temperature was $-1.1^{\circ}C$, was used for the phase-change material. The salt water was packed in silicon cases and inserted between Kimchi container and the copper pipe of the evaporator. The maximum and minimum temperatures of the inner wall of the Kimchi container without salt-water pack were $-0.2^{\circ}C$ and $-8.9^{\circ}C$, which were remarkably improved by using the salt-water packs, resulting $-0.5^{\circ}C$ and$ -1.9^{\circ}C$. This shows a useful application of using phase-change materials for accurate temperature controls.