• 제목/요약/키워드: Minimum Man Power

검색결과 40건 처리시간 0.029초

Home Network Control Protocol for Networked Home Appliances and Its Application

  • Lee Jae-Min;Myoung Kwan-Joo;Kim Dong-Sung;Kwon Wook-Hyun;Ko Beom-Seog;Kim Young-Man;Kim Yo-Hee
    • 정보통신설비학회논문지
    • /
    • 제1권1호
    • /
    • pp.26-39
    • /
    • 2002
  • This paper describes design and implementation of home network control protocol for networked home appliances. The proposed network protocol has four-layered protocol structure and device-modem interface structure for the flexibility of modems based on power line communication. The standard message set is specified to guarantee the interoperability between various home appliances The proposed protocol can be easily implemented because it has minimum network overhead.

  • PDF

Development of A Test Apparatus for Control Rod Drive Mechanism in Nuclear Power Plants

  • Kim, Choon-Kyung;Cheon, Jong-Min;Lee, Jong-Moo;Kim, Seog-Joo;Kwon, Soon-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1732-1735
    • /
    • 2003
  • In this paper, a DSP-based test apparatus for Control Rod Drive Mechanism (CRDM) that is used in nuclear power plants is described. Using this apparatus, we can test the mechanical and electrical characteristics of CRDM and obtain some information about how to improve the CRDM further and how to design a power controller to actuate the CRDM. Since firing angles can be directly applied to the gate-drive circuits of thyristors in the power controller by using this apparatus, the maximum and minimum values of firing angles within available limits are easily measured. Also step-current inputs help us investigate each coil's response characteristics. Therefore, we can easily find the range of control gains which enables a stable CRDM operation in insertion and withdrawal actions at high speed, mid speed, and low speed. Since this apparatus has a test mode in which an insertion or withdrawal action is divided into several phases so that the current command for each phase is given step by step, we may judge whether the CRDM works as expected or not. We also describe a fault detection capability of the test apparatus for the power controller by using discrete Fourier transform.

  • PDF

SP-100 우주선 원자로를 위한 고장진단 및 제어 통합 시스템 (A Fault Diagnosis and Control Integrated System for an SP-100 Space Reactor)

  • 나만균;양헌영;임동혁;이윤준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.231-232
    • /
    • 2007
  • In this paper, a fault diagnosis and control integrated system (FDCIS) was developed to control the thermoelectric (TE) power in the SP-100 space reactor. The objectives of the proposed model predictive control were to minimize both the difference between the predicted TE power and the desired power, and the variation of control drum angle that adjusts the control reactivity. Also, the objectives were subject to maximum and minimum control drum angle and maximum drum angle variation speed. A genetic algorithm was used to optimize the model predictive controller. The model predictive controller was integrated with a fault detection and diagnostics algorithm so that the controller can work properly even under input and output measurement faults. With the presence of faults, the control law was reconfigured using online estimates of the measurements. Simulation results of the proposed controller showed that the TE generator power level controlled by the proposed controller could track the target power level effectively even under measurement faults, satisfying all control constraints.

  • PDF

차량용 Built-in 청소기용 SRM 드라이브 시스템 개발 (Development of SRM Drive System for Built-in Car Vacuum Cleaners)

  • 이영수;노정민;이대진;김재혁;선한걸;한만승
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.193-198
    • /
    • 2017
  • This paper discusses the design and control of a switched reluctance motor (SRM) drive system for a built-in car vacuum cleaner. The growing popularity of outdoor activities and recreation has led the automobile industry to expand technologies that increase the convenience of vehicles, and thus, a built-in car vacuum cleaner was introduced. However, the existing DC motor of a vacuum cleaning system has several disadvantages, such as maintenance cost and lifespan issues of its commutator-brush structure. An SRM can be a good alternative to the existing DC motor because of its high-speed capability, long lifespan, low maintenance cost, and high efficiency, among other advantages. A prototype SRM drive is designed and manufactured to verify its feasibility for use in a built-in car vacuum cleaning system. Dynamic simulation is conducted to determine the optimal switching angle for maximum efficiency and minimum torque ripple. Load test, noise measurement, and suction-power tests are also carried out.

축전지 사용 유무에 따른 태양광발전기의 성능 분석 (Performance Analysis of Photovoltaic Power Generator by Usage Battery Charge)

  • 윤성욱;최만권;김현태;윤용철
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.220-227
    • /
    • 2013
  • 본 연구는 온실 운영에 필요한 전력량을 확보함으로서 온실경영비 절감을 목적으로 태양광발전시스템을 온실에 인접한 건물의 옥상에 설치하여 일사량에 따른 발전량을 실험적으로 검토하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 수평면 일사량의 최대, 평균 및 최소값은 각각 $26.1MJ{\cdot}m^{-2}$, $14.0MJ{\cdot}m^{-2}$$0.6MJ{\cdot}m^{-2}$ 정도였고, 일일 전력량은 각각 약 6.1kWh, 3.7kWh 및 0.01kWh 이었다. 그리고 누계 일사량과 전력량은 각각 약 $4,378.2MJ{\cdot}m^{-2}$ 및 1,163.2kWh 정도이었다. 그리고 부하에 의해 소비된 적산전력량의 최대, 평균 및 최소값은 각각 4.5kWh, 2.4kWh 및 0.0kWh 정도이었고, 누계전력량은 739.2kWh 정도로서 발생 전력량의 약 63.5%에 해당하였다. 본 실험에 사용된 시스템의 평균 소비전력량을 기준으로 보면, 온풍기의 용량 및 작동시간이 작은 경우는 충분하지만 큰 경우는 부족한 것으로 나타났다. 어레이 표면온도가 상대적으로 높아지면 일사량에 비례해서 발생 전력이 증가하지 않은 것으로 나타났지만, 두 인자 간에 상관계수는 0.851 정도로서 상관관계가 높은 것으로 나타났다.

송전계통 보호 협조 전문가 시스템의 개발 (Development of Expert System for Protection Coordination of Transmission Systems)

  • 이승재;박영문;심정욱;윤상현;윤만철;이상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.129-132
    • /
    • 1990
  • This paper reports an expert system for coordination of protective relays in the high voltage transmission system. The proposed system consists of five modules and has adopted the frame and production rule representations achieving the efficient data storage and knowledgebases. It has an interface to the fault program PSS/E and has reduced the data retrival time by implementing the local database containg only the minimum information for the process. Different relay parameters and output formats of the setting results can be easily incorporated owing to the rule-based structure. Graphics-based output helps understanding of the process and enhances the practical power.

  • PDF

하화도 태양광발전시스템의 원격측정 시스템 연구 (Study on Remote Monitoring System for manned island electrification in Korea)

  • 이만근;정명웅;김부호
    • 태양에너지
    • /
    • 제16권2호
    • /
    • pp.7-14
    • /
    • 1996
  • Korean goverment is promoting "the Rural Electrification Project" to replace the diesel generators with PV power supply. The PV-diesel hybrid system are proven more cost effective than that of the existing, especially in the. case of small islands(less than 70 households). In this paper, we intend to introduce the Hahwado island PV system assisted with diesel generator and remote monitoring systems as observator. The purpose of this observator is to have minimum maintenance, to improve economical effciency and system reliability by checking the system periodically at certain time interval, and to make diagnosis of its operating situations. The remote monitoring system was designed to communicate between the central and local site through exclusive telephone line on real-time base, using Window '95 version.

  • PDF

K264 Motion Estimation용 저전력 SAD 프로세서 설계 (Low Power SAD Processor Architecture for Motion Estimation of K264)

  • 김비철;오세만;유현중;장영범
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.263-264
    • /
    • 2007
  • In this paper, an efficient SAD(Sum of Absolute Differences) processor structure for motion estimation of 0.264 is proposed. SAD processors are commonly used both in full search methods for motion estimation or in fast search methods for motion estimation. Proposed structure consists of SAD calculator block, combinator block, and minimum value calculator block. Especially, proposed structure is simplified by using Distributed Arithmetic for addition operation. The Verilog-HDL(Hard Description Language) coding and FPGA implementation results for the proposed structure show 39% and 32% gate count reduction comparison with those of the conventional structure, respectively. Due to its efficient processing scheme, the proposed SAD processor structure can be widely used in size dominant H.264 chip.

  • PDF

에너지 자립 마을 개발을 위한 공력 실증 데이터 분석 (An Analysis of Wind Data for Development of Energy Independent Village)

  • 사지드 알리;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.614-620
    • /
    • 2019
  • In the present study, the wind characteristics were analyzed according to the time averages to evaluate the performance of small wind turbines required for the development of energy independent village. Measuring data of wind speed were recorded between January 2016 and April 2016 every second. Experimental data is averaged out using 5, 10, 15, 20 and 30 minute time steps. Throughout the experimental data analysis, 5 minutes averaged data is used to analyze the performance of the wind turbine, because it produces a minimum turbulence intensity in wind speed. The measuring power of the wind turbine is less than the designed value due to the unsteady nature wind of sudden changes in magnitude of wind speed and wind angle. Detailed wind conditions are also analysed using two variable Weibull probability density functions.

Effect of Particle Size and Dispersion on Dielectric Properties in ZnO/Epoxy Resin Composites

  • Yang, Wenhu;Yi, Ran;Yang, Xu;Xu, Man;Hui, Sisi;Cao, Xiaolong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권3호
    • /
    • pp.116-120
    • /
    • 2012
  • In this paper, ZnO-Epoxy nanocomposites (NEP) were prepared and epoxy composites that contain 5 wt% micro ZnO (MEP) and deliberately not well dispersed nano ZnO (NDNEP) were also prepared for purpose of comparison. The effects of the particle size and dispersion of ZnO on dielectric properties of epoxy resin were chiefly studied. Test results showed that: at a loading of 5 wt%, the three epoxy composites seem to have no significant difference on resistivity compared to epoxy resin; Dielectric constants of all the epoxy composites are also basically the same but they are bigger compared to that of the pure epoxy resin (unfilled); Dielectric dissipation factors ($tan{\delta}$) of NDNEP is greater than that of NEP and MEP. NEP has the minimum dielectric loss factor, whereas dielectric loss factors of the three epoxy composites are larger than that of the pure epoxy resin. The decreasing order of electrical breakdown strength for the three epoxy composites and for the pure epoxy resin is as follows: NEP>MEP>NDNEP>EP. Finally, in order to explain the experimental results the aggregation interface phase was proposed. Furthermore, addition of well dispersed nano filler has proved to have a positive effect on the improvement of the dielectric properties of epoxy resin.