• 제목/요약/키워드: Minimum Building Floors

검색결과 14건 처리시간 0.023초

1950-1970년대 도시미화를 위한 서울 간선도로변 고층화제도의 사적 고찰 (Historical Review on High-rise Buildings-promoting Policies on the Main Roads of Seoul for Urban Beautification from the 1950s to the 1970s)

  • 박일향;전봉희
    • 대한건축학회논문집:계획계
    • /
    • 제35권10호
    • /
    • pp.41-52
    • /
    • 2019
  • The purpose of this study was to analyze the historical development of high-rise buildings-promoting policies in Seoul in terms of modern urban redevelopment. The results of this study were as follows; The maximum height of the buildings has been limited by National codes since 1934. But at the same time, Seoul Metropolitan government had limited the minimum building floors of roadside buildings through local regulations after the Korean War. The high-rise city had been regarded as a means of beautifying Seoul for a long time. However since the 2000s, the minimum height limit for buildings was removed from local regulations and the concept of high-rise restrictions was no longer significant as before.

A study on the comparison of a steel building with braced frames and with RC walls

  • Buyuktaskin, Almila H. Arda
    • Earthquakes and Structures
    • /
    • 제12권3호
    • /
    • pp.263-270
    • /
    • 2017
  • In this study, two geometrically identical multi-storey steel buildings with different lateral load resisting systems are structurally analyzed under same earthquake conditions and they are compared with respect to their construction costs of their structural systems. One of the systems is a steel structure with eccentrically steel braced frames. The other one is a RC wall-steel frame system, that is a steel framed structure in combination with a reinforced concrete core and shear walls of minimum thickness that the national code allows. As earthquake resisting systems, steel braced frames and reinforced concrete shear walls, for both cases are located on identical places in either building. Floors of both buildings will be of reinforced concrete slabs of same thickness resting on composite beams. The façades are assumed to be covered identically with light-weight aluminum cladding with insulation. Purpose of use for both buildings is an office building of eight stories. When two systems are structurally analyzed by FEM (finite element method) and dimensionally compared, the dual one comes up with almost 34% less cost of construction with respect to their structural systems. This in turn means that, by using a dual system in earthquake zones such as Turkey, for multi-storey steel buildings with RC floors, more economical solutions can be achieved. In addition, slender steel columns and beams will add to that and consequently more space in rooms is achieved.

Assessment of damages on a RC building after a big fire

  • Ada, Mehmet;Sevim, Baris;Yuzer, Nabi;Ayvaz, Yusuf
    • Advances in concrete construction
    • /
    • 제6권2호
    • /
    • pp.177-197
    • /
    • 2018
  • This paper presents a case study about the damages on the structural elements of a cast in place reinforced concrete (RC) building after a big fire which was able to be controlled after six hours. The fire broke off at the $2^{nd}$ basement floor of the building, which has five basements, one ground, and two normal floors. As a result of intensely stocked ignitable materials, it spread out to the all of the upstairs. In visual inspection, most of the typical fire damages were observed (such as spalling, net-like cracks, crumbled plasters, bared or visible reinforcement). Also, failures of the $2^{nd}$ basement columns were encountered. It has been concluded that the severity failures of the columns at the $2^{nd}$ basement caused utterly deformation of the building, which is responsible for the massive damages on the beam-column connections. All of the observed damages were categorized related to the types and presented separated regarding the floors. Besides to the visual inspection, the numerical analysis was run to verify the observed damaged on the building for columns, beams, and the connection regions. It is concluded from the study that several parameters such as duration of the fire, level of the temperature influence on the damages to the RC building. Also, it is highlighted by the study that if the damaged building is considered on the overall structural system, it is not able to satisfy the minimum service requirements neither gravity loads nor earthquake conditions.

Full Scale Testing of the Effect of Stairwell Pressurization on Pressure Differential and Flow Velocity

  • Son, Bong-Sae;Park, Kyung-Hwan;Chang, Young-Bae
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.83-89
    • /
    • 2011
  • 계단실을 직접 가압했을 경우에 계단실과 부속실 사이의 차압 및 부속실과 세대 사이의 차압이 어떤 영향을 받는지 연구하기 위해 실건물을 사용해 실험했다. 또한 열린문에서의 유속분포도 측정하였다. 본 연구에 사용된 건물은 지상 20층 지하 2층의 공동주택이다. 계단실을 가압하기 위해서 송풍기를 지하 1층에 설치하여 외부공기를 계단실로 공급했다. 13가지 경우에 대한 실험을 실시했으면 주 실험변수들은 문이 개방된 층의 숫자와 위치 및 송풍량이었다. 지상 1층 문들만이 열린 상태에서는 계단실과 부속실 사이의 차압 및 부속실과 세대 사이의 차압이, 1층 부근을 제외하고는, 비교적 균일하게 분포되었다. 실험결과 180~270 CMM에서 한 층이 개방되어도 화재안전기준의 방연풍속을 만족하였고, 계단실은 전체적으로 양압을 유지할 수 있었으나 최소차압 조건(10 Pa)을 항상 만족시키지는 못하였다. 두 층의 문들이 개방된 경우, 유량을 증가함으로써 최소유속조건은 만족시킬 수 있었으나 가압지점 인근에서 과압이 발생하지 않는 상태에서 최소차압조건을 만족시키는 것은 비현실적임을 발견했다.

광주광역시 광산구 소재 초등학교 라돈가스 농도 계측 (Elementary School in Gwangju Gwangsan Radon gas Density Measurement)

  • 안병주;오지훈
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.211-216
    • /
    • 2014
  • 자연방사선 물질인 라돈($^{222}Rn$)은 암석이나 토양 또는 건축자재 중에 들어있는 우라늄($^{238}U$)이 몇 단계의 방사성 붕괴 과정을 거친 후 생성되는 무색무취의 불활성기체로 지하 근무지나 밀폐된 공간과 같은 곳에서 잘 축적된다. 호흡기를 통하여 허파로 유입되고 라돈의 딸핵종이 허파나 기관지에 침적되어 폐암을 일으키는 원인이 된다. 본 연구에서는 초등학교 교실내의 공기 중 라돈가스농도을 비교하였으며 계측된 값을 이용하여 연간내부피폭량을 계산하였다. 초등학교 교실에서 측정된 라돈가스 피폭은 최소 5개교에서 층별 평균치가 창문을 닫을 때의 경우 1층 0.56mSv, 2층 0.48mSv, 3층 0.384mSv의 평균치가 나왔으며, 창문을 열었을 때의 경우 1층과 2층은 0.31mSv 수치로 같고 3층은 0.296mSv로평균치가 나왔다. 라돈에 대한 인체 피폭은 1층에서 피폭이 많고 3층에서는 피폭이 적었다. 창문을 닫았을 때의 경우 최대 0.56mSv 최소 0.384mSv로 자연방사선에 의한 연간피폭량에 2.4mSv 16%에서 23.3%를 차지하고 있다. 창문을 열었을 때의 경우 최대 0.31mSv 최소 0.296mSv로 연간피폭량 2.4mSv의 12.3%에서 12.91%를 차지한다. 결과로 보아 라돈가스 계측을 실시한 5개 초등학교의 경우 국내의 라돈기준치 이하로 나왔으며 내부피폭 역시 정상범위 내에 속한다. 사람에게 있어서 방사선피폭이 적으면 적을수록 인체에 대한 영향이 줄어들기 때문에 초등학교 교실 내에서 창문을 자주 환기한다면 즉, 공기 중 라돈농도를 최대한 줄인다면 라돈가스에 대한 피폭량을 줄일 수 있을 것이며 면역력이 약한 초등학생에게 도움이 될 것이다. 실험에 있어서 향후 더 많은 초등학교 기관에 대해 라돈가스 조사가 이루어지고 그에 따른 조치를 행한다면 보다 더 안전한 초등학교 건물시설 확립에 도움이 될 것이라 생각된다.

Damage detection of multi-storeyed shear structure using sparse and noisy modal data

  • Panigrahi, S.K.;Chakraverty, S.;Bhattacharyya, S.K.
    • Smart Structures and Systems
    • /
    • 제15권5호
    • /
    • pp.1215-1232
    • /
    • 2015
  • In the present paper, a method for identifying damage in a multi storeyed shear building structure is presented using minimum number of modal parameters of the structure. A damage at any level of the structure may lead to a major failure if the damage is not attended at appropriate time. Hence an early detection of damage is essential. The proposed identification methodology requires experimentally determined sparse modal data of any particular mode as input to detect the location and extent of damage in the structure. Here, the first natural frequency and corresponding partial mode shape values are used as input to the model and results are compared by changing the sensor placement locations at different floors to conclude the best location of sensors for accurate damage identification. Initially experimental data are simulated numerically by solving eigen value problem of the damaged structure with inclusion of random noise on the vibration characteristics. Reliability of the procedure has been demonstrated through a few examples of multi storeyed shear structure with different damage scenarios and various noise levels. Validation of the methodology has also been done using dynamic data obtained through experiment conducted on a laboratory scale steel structure.

외장재에 의한 동시다발적인 화재의 피난위험성에 관한 연구 (A Study on the Evacuation Risk of Simultaneous Fires from Exterior)

  • 민세홍
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.48-54
    • /
    • 2012
  • 외장재의 수직화재에 의한 동시다발적인 화재 발생 시 피난위험성을 확인하기 위하여 시나리오에 의한 피난시뮬레이션을 수행하였다. 피난시뮬레이션 결과, 가연성 외장재가 연소하면서 수직화재로 확대되어 개구부를 통해 유입되는 화재에 의해 층 대부분이 550초에서 650초 사이에 허용피난안전시간에 도달하였고, 특히 1층은 358초에, 6층과 10층은 490초와 473초에 피난한계에 도달하였다. 또한, 1층과 26층, 28층~30층의 총 5개 층에서 피난위험성이 나타나는 것으로 분석되었다. 동시다발적인 화재성상으로 인해 모든 재실자가 전관 피난을 하여 15층 이상의 고층 부분에서 병목현상이 심하게 발생하여 피난계단으로 진입이 어렵다는 것을 확인하였다. 특히, 1층의 경우는 발화지점과 가까워서 358초에 허용안전피난시간에 도달하여 상부층에 있는 699명의 피난이 난해한 것으로 분석되었다. 외장재 화재의 위험성 대책으로 불연성 외장재의 사용과 연소 확대를 방지하기 위한 적극적인 진압방법의 도입이 요구된다.

초고층 건축물 수직조닝별 연돌효과의 원인 및 해결 방안 분석 (Analysis of Causes of and Solutions to the Stack Effect by Vertical Zoning of High-rise Buildings)

  • 신상욱;류종우;정희웅;김대영
    • 한국건축시공학회지
    • /
    • 제21권5호
    • /
    • pp.483-493
    • /
    • 2021
  • 도시 인구의 과밀화로 고층 건물에 대한 폭발적인 수요와 공급이 발생하였다. 고층 빌딩은 각 도시의 구심점으로 도시 이미지를 제고하는데 기여하고 있으나 연돌효과로 인해 승강기 문의 오작동, 외벽의 문과 창문 개폐의 어려움, 상층부로 확산하는 연기와 악취, 소음, 에너지 손실, 화재 및 오염물질의 급속한 확산 등 예기치 못한 다양한 문제를 야기하고 있다. 본 연구에서는 초고층 건축물을 수직조닝별로 구분하여 연돌효과의 원인과 해결방안을 분석하고 설계와 시공 방안으로 도출하였다. 외기를 차단하는 초기 계획과 정밀한 시공을 통한 기밀성 확보를 통해 저층부에서 유입되는 기류를 능동적으로 차단하여 건물의 내·외부 기밀성을 확보하는 방안을 모색하였다. 설비적 해결대책은 연돌효과로 인한 특정 현상을 줄이기 위한 대책이 될 수 있으나 이에 따른 2차 피해의 가능성이 높기 때문에 최소한으로 적용해야 한다. 따라서 본 연구는 연돌효과의 원인과 대책방안을 수직 조닝별로 설계적, 시공적 대책을 제시함으로써 체계적인 연돌효과 관리의 필요성을 역설하였다. 또한 본 연구가 설계 및 시공뿐만 아니라 건물 유지관리에도 도움이 되기를 기대한다.

재건축에 따른 건축밀도 및 주거환경의 변화 연구 (A Study on the Change of Architecture Density and Residential Environment according to Reconstruction)

  • 김홍배
    • 한국농촌건축학회논문집
    • /
    • 제19권1호
    • /
    • pp.35-42
    • /
    • 2017
  • This study aims to investigate the change in building density and residential environment after the reconstruction of decrepit public rental housing complexes formed in accordance with the Land Readjustment Project during the 1970s-80s. The results of this study can be summarized as follows: First, in terms of change in residential environment after the reconstruction, floor plans that were limited to two to four types and to small apartments measuring $42.9m^2$(13py)-$56.1m^2$ (17py) became varied, presenting 5-6 types of floor plans and various sizes of apartments. In particular, the reconstructed apartments were mainly built in a size smaller than 85($m^2$) and in the 3LDK floor plan and staircase-style unit architectural structure in order to reflect the lifestyle of residents. Second, in terms of change in building density after the reconstruction, the building coverage ratio did not change a lot, but the floor area ratio showed great change depending on the complex, ranging from a minimum of 2.9 times (Singdong Complex) to a maximum of 5.4 times (Eoyangdong Complex). Such change is attributable to the reconstruction policy that aims to improve the residential environment for original residents, secure economic feasibility and efficiency, and reflect the lifestyle of residents while incorporating dividends assigned to the existing housing project members as well as the maximum floor area ratio allowed by the regulation. Additionally, in terms of change in the number of floors and building density after the reconstruction, the former 5-story apartments were changed to apartments with 16-28 stories. Accordingly, the number of households in each complex has also increased by 20%. Third, according to the characteristics of parking facilities in terms of the size and density of parking spaces, former apartment complexes had only aboveground parking lots, not underground parking area. The newly constructed apartment complexes have underground parking space, and the parking-housing ratio is 1.1-1.3 cars.

시공기간을 고려한 주거용 철근콘크리트 건물의 시공 중 지진하중 영향 분석 (Effect of Seismic Load on Residential RC Buildings under Construction Considering Construction Period)

  • 최성현;김재요
    • 한국전산구조공학회논문집
    • /
    • 제35권4호
    • /
    • pp.235-242
    • /
    • 2022
  • 시공 중인 건물은 시공이 완료된 건물과는 다르게 콘크리트의 강도발현이 충분히 이루어지지 않았기 때문에 지진과 같은 자연재해에 더 취약한 모습을 가질 수 있다. 현재 국내 기준은 건축물의 내진등급별 최소성능 목표를 제시하고 있지만, 설계를 위한 지진하중은 재현주기 2,400년의 지진위험도를 기반으로 한다. 하지만 건물의 시공기간은 건물의 사용기간보다 훨씬 짧기 때문에 재현주기 2,400년의 지진을 시공 중인 건물에 적용하는 것은 과도하다. 따라서 이 연구는 주거용으로 사용되는 철근콘크리트 건물의 시공 중 지진하중을 분석하기 위해 5층, 15층, 25층, 60층 건물의 시공단계모델을 작성하고 재현주기에 따라 저감한 지진하중을 적용하여 구조적 안정성을 확인하였다. 그 결과, 시공기간에 따라 선정한 재현주기의 지진을 적용할 때 구조적 안정성을 확인하였으며, 건물의 규모의 따라 구조적 안전성을 확보할 수 있는 지진재현주기를 확인하였다.