• Title/Summary/Keyword: Minimal construction

Search Result 190, Processing Time 0.026 seconds

A Study on the Original Form and Architectural Elements in the Palace of Yu, Jin gyeong's Hanok (유진경 가옥(현 북촌문화센터)의 원형과 궁궐요소 차용)

  • Park, Sang-Wook
    • Journal of architectural history
    • /
    • v.23 no.5
    • /
    • pp.7-22
    • /
    • 2014
  • It is identified that an initial person who built of 'Seoul Gyedong Modernized Hanok(former Min Hyeong-gi house)' used as 'Bukchon Culture Center' in present, was not Min Hyeong-gi, but his wife, Yu Jin-gyeong, and she built it when 8 years went on after his death(1879~1973), and the construction year was at the gate of Chuseok in 1921. Yu Jin-gyeong was Head Family's Eldest Daughter-in-law in family of Yeo Heung-min who was an influential person at the late Joseon Dynasty and was widow who had only son for 3 generations. And she built this house and moved to gain daughter and live futher grandchilds together in law in new nest. It is arranged that an annex surrounds with main building as the central figure. And this house emulates Yeonkeong-dang in backyard of the Changdeok Palace for 'preservation of main building' and Chim-bang-ga-toe applied on a bedroom in a palace is applied around nobleman family's the main room. It is rare case and expresses that a palace factor is borrowed. Yu Jin-gyeong's house is that a tradition Hanok is adjusted closely in city and central and basing mode as 'protective bedding' and building concept as 'a noble and protective architecture' is realized. So it has a character that development of Hangrang architecture is appeared and Head Family's Eldest Daughter-in-law widow of modern upper class had a special benefit. As well as, a meaning that it is experimental house based on tradition and is build of Hanok with housekeeping as the central figure for appear a form which has minimal Hangrang for housekeeping in yangban family of modern city, can be found.

Compressive Strength Properties of Geopolymers from Pond Ash and Possibility of Utilization as Synthetic Basalt

  • Kim, Byoungkwan;Lee, Bokyeong;Chon, Chul-Min;Lee, Sujeong
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.4
    • /
    • pp.365-373
    • /
    • 2019
  • Pond ash is a mixture of mostly coarser fly ash and bottom ash. The recycling rate of pond ash is low because pond ash is mixed with seawater and deposited in ponds. The pond ash is also subjected to natural weathering over a period of time. In this study, we investigated whether pond ash can be used as a raw material of geopolymers, without any purification process or through a minimal purification process. In addition, we investigated whether synthetic basalt made by adding foaming agent to geopolymer or casting it into a mold can show the surface of the natural basalt as it is. The highest 7-day compressive strength in geopolymers from pond ash without purification process was 26 MPa. The highest 7-day compressive strength in geopolymers from pond ash with impurities removed through dry sieve analysis was found to improve to 80 MPa. On the other hand, synthetic basalt made with geopolymer was shown to be more advantageous aesthetically when produced by casting it in a silicone mold rather than by adding a foaming agent. Non-purified pond ash can be made into geopolymers having low strength. Pond ash purified by sieving can, without use of an aggregate, be made into geopolymer having high-strength. Also, it is possible to produce synthetic basalt with the same appearance as natural basalt and sufficient strength for commercialization. This process will contribute to the mass consumption and recycling of pond ash.

Characteristics of Natural Light used in Space of Kengo Kuma's Projects (쿠마 켄고의 공간에 나타나는 빛 표현 특성에 관한 연구)

  • Koh, Kwang-Yong;Kim, Moon-Duck
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.4
    • /
    • pp.51-59
    • /
    • 2016
  • Recent modern architecture shows a lot of cases that introduce natural light in indoor space, arousing diverse emotions within a minimal space by means of changes in the light. There are various causes for the background of these streams of times, and it may be said that pursuing the relationship between natural phenomena and space, using changes in light, is an important factor among them. This is closely linked to the raise of phenomenological architecture. In the case of Japan, there are many cases where the architectural language connected to the traditional architecture has been restructured to fit to modern architectural technique. The modern reinterpretation and development of the Japanese traditional effect of light and its meaning can be seen in cases of Kuma Kengo and Tadao Anndo. Of the modern architects that have used the appearance of spatial concept of light in Japanese architectural space, Kengo Kuma shows his attempt at finding identity in his designs through the acceptance and modern reinterpretation of orientalism of nature, along with the traditional and regional interpretation through materials and ways construction. It is his use oh light input used in traditional Japanese settings that have differentiated his work. On this, the present thesis intends to analyze and synthesize what impressions Kengo Kuma's unique methods of light production create in the formation of users' spatial perception, how the unique encounter of light and materials seems to perceivers, and the characteristics of his light production and expression that harmonize space, human, and nature in the visual and perceptual experience of space;

Elevated temperature resistance of concrete columns with axial loading

  • Alaskar, Abdulaziz;Alyousef, Rayed;Alabduljabbar, Hisham;Alrshoudi, Fahed;Mohamed, Abdeliazim Mustafa;Jermsittiparsert, Kittisak;Ho, Lanh Si
    • Advances in concrete construction
    • /
    • v.9 no.4
    • /
    • pp.355-365
    • /
    • 2020
  • The influence of temperature on the material of concrete filled columns (CFCs) under axial loading has been quantitatively studied in this research. CFCs have many various advantages and disadvantages. One of the important inefficiency of classic CFCs design is the practical lack of hooped compression under the operational loads because of the fewer variables of Poisson's rate of concrete compared to steel. This is the reason why the holder tends to break away from the concrete core in elastic stage. It is also suggested to produce concrete filled steel tube columns with an initial compressed concrete core to surpass their design. Elevated temperatures have essentially reduced the strengths of steel tubes and the final capacity of CFCs exposed to fire. Thus, the computation of bearing capacity of concrete filled steel tube columns is studied here. Sometimes, the structures of concrete could be exposed to the high temperatures during altered times, accordingly, outcomes have shown a decrement in compressive-strength, then an increase with the reduction of this content. In addition, the moisture content at the minimal strength is declined with temperature rising. According to Finite Element (FE), the column performance assessment is carried out according to the axial load carrying capacities and the improvement of ductility and strength because of limitations. Self-stress could significantly develop the ultimate stiffness and capacity of concrete columns. In addition, the design equations for the ultimate capacity of concrete columns have been offered and the predictions satisfactorily agree with the numerical results. The proposed based model (FE model of PEC column) 65% aligns with the concrete exposed to high temperature. Therefore, computed solutions have represented a better perception of structural and thermal responses of CFC in fire.

Design and Implementation of an Efficient Bulk Loading Algorithm for CIR-Tree (CIR-Tree를 위한 효율적인 대량적재 알고리즘의 설계 및 구현)

  • Pi, Jun-Il;Song, Seok-Il;Yu, Jae-Su
    • Journal of KIISE:Databases
    • /
    • v.29 no.3
    • /
    • pp.193-206
    • /
    • 2002
  • In this paper, we design and implement an efficient bulk-loading algorithm for CIR-Tree. Bulk-loading techniques increase node utilization, improve query performance and reduce index construction time. The CIR-tree has variable size of internal node entries since it only maintains minimal dimensions to decriminate child nodes. This property increases fan-out of internal nodes and improves search performance. Even though several bulk-loading algorithms for multi/high-dimensional index structures have been proposed, we cannot apple them to CIR-tree because of the variable size of internal node entries. In this paper, we propose an efficient bulk- loading algorithm for CIR-tree that improves the existing bulk-loading algorithm and accomodates the property of CIR-tree. We also implement it on a storage system MiDAS-III and show superiority of our algorithm through various experiments.

Molecular Characteristics of Pseudomonas rhodesiae Strain KK1 in Response to Phenanthrene

  • Kahng, Hyung-Yeel;Nam, Kyoung-Phile
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.5
    • /
    • pp.729-734
    • /
    • 2002
  • Radiorespirometric analysis revealed that Pseudomonas sp. strain KKI isolated from a soil contaminated with petroleum hydrocarbons was able to catabolize polycyclic aromatic hydrocarbons such as phenanthrene and naphthalene. The rate and extent of phenanthrene mineralization was markedly enhanced when the cells were pregrown on either naphthalene or phenanthrene, compared to the cells grown on universal carbon sources (i.e., TSA medium). Deduced amino acid sequence of the Rieske-type iron-sulfur center of a putative phenanthrene dioxygenase (PhnAl) obtained from the strain KKI shared significant homology with DxnAl (dioxin dioxygenase) from Spingomonas sp. RW1, BphA1b (biphenyl dioxygenase) from Spingomonas aromaticivorans F199, and PhnAc (phenanthrene diokygenase) from Burkholderia sp. RP007 or Alcaligenes faecalis AFK2. Northern hybridization using the dioxygenase gene fragment cloned from KKI showed that the expression of the putative phn dioxygenase gene reached the highest level in cells grown in the minimal medium containing phenanthrene and $KNO_3$, and the expression of the phn gene was repressed in cells grown with glucose. In addition to the metabolic change, phospholipid ester-linked fatty acids (PLFA) analysis revealed that the total cellular fatty acid composition of KKI was significantly changed in response to phenanthrene. Fatty acids such as 14:0, 16:0 3OH, 17:0 cyclo, 18:1$\omega$7c, 19:0 cyclo increased in phenanthrene-exposed cells, while fatty acids such as 10:0 3OH, 12:0, 12:0 2OH, 12:0 3OH, 16:1$\omega$7c, 15:0 iso 2OH, 16:0, 18:1$\omega$6c, 18:0 decreased.

Efficient Designs to Develop a Design Space in Mixture Response Surface Analysis (혼합물 반응표면분석에서 디자인 스페이스 구축을 위한 효율적인 실험계획)

  • Chung, Jong Hee;Lim, Yong B.
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.2
    • /
    • pp.269-282
    • /
    • 2020
  • Purpose: The practical design for experiments with mixtures of q components is consisted in the four types of design points, vertex, center of edge, axial, and center points in a (q-1)-dimensional simplex space. We propose a sequential method for the successful construction of the design space in Quality by Design (QbD) by allowing the different number of replicates at the four types of design points in the practical design when the quadratic canonical polynomial model is assumed. Methods: To compare the mixture designs efficiency, fraction of design space (FDS) plot is used. We search for the practical mixture designs whose the minimal half-width of the tolerance interval per a standard deviation, which is denoted as d2, is less than 4.5 at 0.8 fraction of the design space. They are found by adding the different number of replicates at the four types of the design points in the practical design. Results: The practical efficient mixture designs for the number of components between three and five are listed. The sequential method to establish a design space is illustrated with the two examples based on the simulated data. Conclusion: The designs with the center of edge points replications are more efficient than those with the vertex points replication. We propose the sample size of at least 23 for three components, 28 for four components, and 33 for the five components based on the list of efficient mixture designs.

A Case Study on the Restoration of Collapsed Geosynthetics Reinforced Soil Wall Using Limit Equilibrium and Numerical Analyses (한계평형해석과 수치해석에 의한 붕괴된 보강토 옹벽 복구 사례에 관한 연구)

  • Won, Myoung-Soo;Kim, Hyeong-Joo;Kim, Young-Shin;Choi, Jeong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.11
    • /
    • pp.107-118
    • /
    • 2013
  • Geosynthetic reinforced soil (GRS) walls have been increasingly applied recently due to its numerous geotechnical engineering applications. However failure occurs in some cases of constructed GRS walls. These GRS wall failures are mostly due to the unpredictable characteristics of intensive rainfall. Hence, the need for new and innovative ideas for rehabilitation methods has been getting attention. This paper introduces a case study for the design and restoration method of collapsed GRS wall using Limit equilibrium and Numerical Analyses. Restoration method includes: (1) soil nailing without backfill excavation and (2) reconstruction with GRS wall after collapsed backfill excavation. Analyses results show minimal horizontal displacements and shear strain on the reinforced concrete facing for the restoration case with soil nailing. On the other hand, horizontal displacements are developed in the middle of the mortar block facing and shear strains are developed at the bottom facing with spiral curves for the reconstructed GRS wall after collapsed backfill excavation. Therefore, the collapsed GRS wall was restored with the soil nailing without backfill excavation and its construction procedures are discussed in this paper.

A Study on the Adaptive Reuse Techniques through the History of Buildings in the Historic Urban Area - Focused on the Deep and Narrow Lots of Nammun-ro 2Ga, Cheongju - (역사적 도심 내 건축물의 이력을 통해 본 재생기법에 관한 연구 -청주시 남문로 2가동의 세장형 필지를 대상으로-)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • This study is intended to derive the adaptive reuse techniques through the history and aspects of new construction, extension, repair, and other works, limited to the deep and narrow lots facing Seongan-gil and Nammun-gil in Nammun-ro 2 ga of Cheongju, the historic urban area. The results are as follows. 1) In the case of newly built reinforced concrete buildings, the central part of the top floor of the residence or all floors are opened to the open space(void) to facilitate lighting and ventilation. This is developed as a convection phenomenon due to the temperature difference from the slits between buildings, which affects the entire air flow of the block. 2) The buildings of extension and repair are composed of two-story masonry or steel frame, both the front store facing the road and the house on the back, but it looks like one because it is in contact with each other. If only a small gap between the front and rear buildings is restored to an external space or a space equipped with sun light, a small breath can be provided in lighting and ventilation. 3) The existing two-story wooden stores and houses have lost their external space due to repairs. With minimal intervention to restore the small courtyard, slits, and space under the eaves, it will not only improve lighting and ventilation, but also create a unique appearance as a segment of the elongated store.

Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers (보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법)

  • Jung, Jae-Jin;Song, Jung-Il
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF