• Title/Summary/Keyword: Mineral oils

Search Result 103, Processing Time 0.028 seconds

Study on vehicle application of biodegradable hydraulic oils from the point of tribological evaluation technology (Tribology 관점에서 생분해성 유압작동유 실적용 평가에 관한 연구)

  • Na ByungChul;Kim JinYong;Seo JoonHo
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.367-371
    • /
    • 2004
  • Bio-degradable hydraulic oil using polyolester base oil is formulated for the applications of heavy duty hydraulic machineries. It has proved quality and market price competitiveness by assessment of reliability test in vehicle manufacturer and specific vehicle related institute. Contribution of bio-degradable oil keep the working environment clean and increase export competitiveness in European market. Leakage or waste of mineral types of hydraulic oils in heavy duty machineries causes pollution of river, ocean, underground water. Drinkable-water pollution is serious problem in Europe. In some European countries, using bio-degradable hydraulic oils become an obligation in heavy duty machineries. New product of bio-degradable oils satisfy the European regulations(OECD 302B) and shows excellent performance in compare with European products.

  • PDF

Synthesis and Characterization of Soybean-based Ester Insulation Oils (대두유 에스테르계 절연유의 합성과 분석)

  • Han Dong-Hee;Cho Han-Goo;Han Se-Won;Oh Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.1
    • /
    • pp.40-45
    • /
    • 2006
  • Electrical insulation is one of the most important parts in a high voltage apparatus. Traditionally mineral oils and synthetic esters have been widely used as dielectric coolants for power transformers. Recently, researchers are interested in the environmentally friendly vegetable oil from the environmental viewpoint. This paper reports on the synthesis and characterization of soybean based ester oils. Two different types of soybean based transformer oils, named as methyl ester and isopropyl ester were synthesized. The synthesis of these esters was achieved by transesterification reactions between soybean oil and alcohol in the presence of catalyst. The GC and NMR spectroscopic analysis of the esters have been performed. It was observed that isopropyl ester has better thermal resistance than methyl ester by TGA. Also, two esters have a good breakdown voltage and electrical resistance.

Lubricating Mechanism Analyzed from Wear Characteristics of Polyolester Base Oils Haying different Branch Shapes(II) (서로 다른 모양의 가지사슬을 갖는 폴리올에스터 오일의 마모특성으로부터 해석된 윤활작용 메커니즘(II))

  • 한두희;마사부미마스꼬
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.171-178
    • /
    • 2001
  • In order to elucidate the lubricating mechanism of polyolester base oils [POEs], the wear characteristics of 27 kinds of polyolester base oils including mixed POEs were investigated. Their wear results were discussed in terms of the effect of molecular structure on wear performance and compared with those of mineral oil. In addition, the adsorption ability of POEs to reduced iron and their hydrolysis rates were measured and the effect of their molecular structures on the adsorptivity and hydrolysis rate of POEs was discussed, respectively. Finally, the lubricating mechanism anlyzed from these results of wear characteristics, adsorptivity and hydrolysis rate was proposed. That is to say, POEs are firstly adsorbed to friction surface and decomposed by hydrolysis or thermal degradation. Fatty acids obtained by degradation of POEs form adsorption film on friction surface. The larger become cohesive ability among fatty acid molecules in the adsorption film, the better gets the wear performance of POEs.

Study on the synthesis and characterization of soybean based transformer oils (대두유 에스테르계 절연유의 합성과 분석)

  • Han, Dong-Hee;Cho, Han-Goo;Han, Se-Won;Ahn, Myeong-Sang;Oho, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.244-245
    • /
    • 2005
  • Electrical insulation is one of the most important parts in a high voltage apparatus. Traditionally mineral oils and synthetic esters have been widely used as dielectric coolants for power transformers. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. This paper reports on the synthesis and characterization of soybean based ester oils. Two different types of soybean based transformer oils, named as methyl ester and isopropyl ester were synthesized. The synthesis of these esters was achieved by transesterification reactions of soybean oil and alcohol in the presence of catalyst. The GC and NMR spectroscopic analysis of the esters have been performed. The thermal stability of the esters was determined by thermal gravimetric analysis(TGA).

  • PDF

Antioxidation synergism between ZnDTC and ZnDTP in mineral oil

  • Du, Da-Chang;Kim, Seock-Sam;Chun, Jung-Sik;Kwon, Wan-Seop;Suh, Chang-Min
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.305-312
    • /
    • 2001
  • Antioxidation synergism between ZnDTC and ZnDTP in a kind of mineral base oil was investigated by RBOT. The results indicate that there is antioxidation synergism between the two additives. FTIR analysis show that the oxidation products in the tested oils containing the two additives are much less than those in the tested oils containing the single additive alone.

  • PDF

The Lightning Impulse Properties and Breakdown Voltage of Natural Ester Fluids Near the Pour Point

  • Choi, Sun-Ho;Huh, Chang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.524-529
    • /
    • 2013
  • Recently, researchers have become interested in natural ester fluids, as they are an environmentally friendly alternative to mineral oils. Natural ester fluids are a natural resource made from plants; they have higher biodegradability, flash, and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester fluids also have a higher pour point, viscosity, and water content. These characteristics can hamper circulation and impair the electrical properties of an oil-filled transformer. A large amount of data has been accumulated over the years in regards to mineral insulating oil involving dielectric breakdown voltage and lightning impulse tests. However, natural ester fluids have not had their electrical properties sufficiently characterized. In this paper, we present an investigation into the characteristics of the electrical discharge development in natural ester fluids and in an oil-filled transformer near the pour points. The experiment results show that the electrical properties decreased according to a decrease in the ambient temperature and freezing time. It was found that the pour point and water content of natural ester fluids have a significant effect on the electrical properties.

Critical Review on Carcinogenicity of Metalworking Fluids (절삭유(Metalworking Fluids)의 발암성에 대한 고찰)

  • 박동욱;윤충식;이송권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.50-62
    • /
    • 2003
  • Exposure to metalworking fluids (MWFs) has significantly been associated with cancer developed in multi-organs, respiratory diseases and skin diseases. Several carcinogens to humans or animals are contained in MWFs. They have been reported to be mineral oils, polynuclear aromatic hydrocarbons (PAHs), formaldehyde and N-nitrosodiethanolamine (NDELA). The great hazards of MWF have forced the advanced country including United States to regulate carcinogens contained in MWF. In 2001, American Conference of Governmental Industrial Hygienists (ACGIHs) regarded MWF mist as suspected carcinogen to human (A2) and added it to “Notice of Intended Change (NIC)” list of 2001. In spite of the fact that much MWF has widely been used in many industries using machines, Korea has no legal actions for management of MWF. What is worse, even toxicity such as Carcinogenicity has not been reported. KS (Korean Standards) lists 7 advices of MWF but it does net state the hazards to health. It is very hard to control or minimize worker's exposure to MWF containing many carcinogens. Prier to the introduction of MWF to workplace, it is the most effective measure to regulate carcinogens below a certain level. Regulation on the content of PAH seems to be necessary because less amount of PAH in mineral oils improves the quality of MWF. Also, addition of nitrosating groups to MWF should be prohibited to minimize worker's exposure to NDELA. Employers and manufacturers should indicate the Carcinogenicity of all carcinogens in MWFs in Material Safety Data Sheets (MSDS) in order fer workers to recognize Carcinogenicity. Legal actions have to be taken to protect workers from health hazards due to exposure to MWF by further investigation on MWF.

Synthesis of POSS Derived Organic-Inorganic Hybrid Esters for Insulating Oil Applications

  • Choi, Kyeong-Min;Harshavardhan, S.J.;Sridhar, Ch.;Vijaykumar, B.V.D.;Kumar, Deepak;Jang, Kiwan;Lee, Man-Sig;Shin, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2769-2773
    • /
    • 2014
  • In this work, a new family of polyhedral oligomeric silsesquioxanes (POSS) based esters have been synthesized that consists eight ester functional groups. These are classified into Type-I and Type-II esters based on the starting materials, octakis(3-chloropropyl)silsesquioxane (Cl-POSS) and octakis(3-hydroxypropyldimethylsiloxy) octasilsesquioxane (OHPS) respectively. These new POSS type ester moieties can be used as insulating oils and oil additives in the transformers and also considered to be alternatives to mineral and vegetable oils that are presently used in the insulation system.

The Prediction of Scuffing Life due to Plastic Deformation and Low-cycle Fatigue Properties Under Various Lubricated Conditions (윤활환경에 따라 발생하는 소성변형량과 저주기 피로물성을 이용한 스커핑 수명 예측)

  • 김병주;이영제
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.7-14
    • /
    • 1998
  • A correlation between the low-cycle fatigue life and the scuffing-failure life is demonstrated using the plastic strain increment in boundary lubricated sliding. Loadings proportional to hardness with three different lubricated conditions were used to evaluate the plastic strain increments. As the results of scuffing tests using vacuum pump oils in nitrogen gas, plastic strain increment shows 0.0062, and in the mineral oils and commercial engine oils in air, plastic strain increments show 0.0042 and 0.00092. Those are very useful to describe quantitatively the real lubricated sliding conditions, and are very effective to find the relation between the low-cycle fatigue life and the scuffing-failure life.

Acute and 2 Weeks Repeated Irritation Study of Cutting oils

  • Lim, Cheol-Hong;Kim, Hyeon-Young;Jeon, Yoon-Seok;Yu, Il-Je
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2001.05a
    • /
    • pp.134-134
    • /
    • 2001
  • Cutting oils are complex mixtures of hydrocarbons, comprising of certain fractions of mineral oil, which are being frequently used as lubricating and heat transferring agents in various machine and tool industries. We investigated an acute and 2 weeks repeated irritation studies of two cutting oils (Cimperial 1010 as water-soluble cutting oil, and MSN 120 as insoluble cutting oil) using guinea pigs.(omitted)

  • PDF