• Title/Summary/Keyword: Milling device

Search Result 59, Processing Time 0.038 seconds

Development of Brown Rice Separator Using Electrostatic Properties of Rice -Electrostatic Properties of Rice- (정전특성(靜電特性)을 이용(利用)한 현미(玄米) 분리기(分離機)의 개발(開發)에 관한 기초(基礎) 연구(硏究) - 벼의 정전특성(靜電特性)에 관하여 -)

  • Noh, S.H.;Yoon, Y.K.;Lee, J.W.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.3
    • /
    • pp.272-284
    • /
    • 1992
  • As a preliminary step toward the development of a multipurpose electrostatic separator for agricultural use, this study investigated the effect of moisture level, geometrical characteristics and the electric field strength of a charging device on the electrostatic charging of brown rice, unhulled paddy, small stones and broken rice that are produced during the milling process. The results are summarized as follows. 1. Average electrostatic charge per unit mass of paddy is greater than that of brown rice. 2. Charge per unit mass of rice kernel increases linearly with moisture content and electric field strength of the charging device, presenting no correlations with length or thickness of rice kernel. 3. Frequency distributions in electrostatic charge per unit mass of paddy and brown rice kernels indicated that the portion, not overlapped, ranged from 10 to 29% with Japonica rice and from 32 to 49% with Indica rice. 4. The difference in moisture content between paddy and brown rice must be over 6%, if they are to be electrostatically separated to over 95%. 5. Theoretical portions of brown rice to be separated from a mixture primarily by the electrostatic charge and secondarily by the length or by the thickness were 95~100% and 27~76%, respectively. 6. Frequency distribution of electrostatic charge for broken kernels overlapped that of paddy and brown rice, which the small stones didn't.

  • PDF

The Application of CAD/CAM in Dentistry (임상가를 위한 특집 1 - CAD/CAM 치과적 응용)

  • Choi, Ho-Sik;Moon, Ji-Eun;Kim, Sung-Hun
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.110-117
    • /
    • 2012
  • Dental computer-aided design (CAD) and computer-aided manufacturing (CAM) technology have rapidly progressed over the past 30 years. The technology, which can be used in the dental laboratory, the dental office and the form of production centers, has become more common in recent years. This technology is now applied to inlays, onlays, crowns, fixed partial dentures, removable partial denture frameworks, complete dentures, templates for implant installation, implant abutments, and even maxillofacial prostheses. Dentists and dental technicians, who want to use these techniques, should have certain basic knowledge about that. This article gives an overview of CAD/CAM technologies, histories and how it applies in prosthetic dentistry.

Burrless shearing of the micro wire (미세 와이어의 버 없는 전단에 관한 연구)

  • Kim Woong-Kyum;Hong Nam-Pyo;Kim Heon-Young;Kim Byeong-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.52-56
    • /
    • 2006
  • Punching tools like an electrodes are made by milling or etching or EDM. These methods had time consuming, low efficiency and air pollution. So, we have developed a shearing device which counter punching method for burrless cutting of micro wire. Using the straightened SUS304 wire with $200{\mu}m$ diameter, we confirmed the tendency of the shear plane for punch tools. It was impossible to completely remove the bun in the shearing process. In order to minimize the burr size and fine shear plane, we have accomplished the various experiment conditions such as the U-groove, the effect of the counter punch, shear angle and clearance. The results of the experiments show that indentation, slip plane and bent shape were related to the shear angle and clearance.

Nano-size Patterning with a High Transmission C-shaped Aperture (고 투과 C 형 개구를 이용한 나노 크기 패턴 구현)

  • Park, Sin-Jeung;Kim, Yong-Woo;Lee, Eung-Man;Hahn, Jae-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.11
    • /
    • pp.108-115
    • /
    • 2007
  • We have designed a high transmission C-shaped aperture using finite differential time domain (FDTD) technique. The C-shaped aperture was fabricated in the aluminum thin film on a glass substrate using a focused ion beam (FIB) milling. Nano-size patterning was demonstrated with a vacuum contact device to keep tight contact between the Al mask and the photoresist. Using 405 nm laser, we recorded a 50 nm-size dot pattern on the photoresist with the aperture and analyzed the spot size dependent on the dose illuminated on the aperture.

Noise Properties of Directly-coupled Single-layer High-Tc 2nd-order SQUID Gradiometer

  • 황윤석;안종록;강찬석;이순걸;김진태
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.163-167
    • /
    • 2002
  • We have fabricated planar-type single-layer second-order high-Tc SQUID gradiometers. The devices consisted of symmetrically designed three parallel-connected square pickup loops that were directly coupled to the SQUID. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ substrate by a PLD system and patterned into a device by the photolithography with ion milling technique. Junctions of the SQUID were either step-edge or bicrystal type. All the structures were formed on a 10 mm $\times$ 5 mm substrate. Balancing of the gradiometer was achieved by adjusting the width of the central pickup loop. The gradiometer noise was measured both inside and outside a magnetically shielded room. Details of the results will be discussed.

  • PDF

Fabrication and Characterization of Thermoelectric Thick Film by Using Bi-Te-Sb Powders

  • Yu, Ji-Hun;Bae, Seung-Chul;Ha, Gook-Hyun;Kim, Ook-Jung;Lee, Gil-Gun
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.430-431
    • /
    • 2006
  • Thermoelectric thick film was fabricated by screen printing process with using p-type Bi-Te-Sb powders. The powder was synthesized by melting, milling and sintering process and hydrogen reduced to enhance the thermoelectric property. The thick film of Bi-Te-Sb powder was fabricated by screen printing method and baked at the optimized conditions. The thermal conductivity, the electrical resistivity and Seeback coefficient of thick film were measured and the thermoelectric performance was analyzed in terms of film characteristics and its microstructure. Finally, the feasibility of thermoelectric thick film into micro cooling device on CPU chip was discussed in this study.

  • PDF

Screen printed $BaSrTiO_3$ composite for embedded capacitor apprication (Embedded capacitor 적용을 위한 screen printed $BaSrTiO_3$ 복합체)

  • Park, Yong-Jun;Koh, JUng-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.311-312
    • /
    • 2007
  • In this study, composite $BaSrTiO_3$ has been studied for high frequency device applications. Composite $Ba_{0.5}Sr_{0.5}TiO_3$ has high dielectric permittivity and low loss tangent at the relative frequency range from MHz to GHz. 10,30 and 50 wt% of epoxy doped $Ba_{0.5}Sr_{0.5}TiO_3$ powders were prepared with bisphenol A and F polymer employing ball milling process. Epoxy/($BaSrTiO_3$) composites thick films were screen printed on the Cu plated PCB substrates through screen printing methods. The specimens were designed for the embedded capacitor applications. Temperature dependent dielectric permittivity of Epoxy doped $BaSrTiO_3$ ceramics was measured.

  • PDF

Clinical Application of 3-D Compensator in Head and Neck Cancer (두경부암 환자 치료시 3차원 보상체의 임상 적용에 대한 고찰)

  • Hong, Dong-Ki;Lee, Jeong-Woo;Lee, Koo-Hyun;Park, Kwang-Ho;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.64-70
    • /
    • 1997
  • The goal of radiation treatment planning is to deliver the dose to the patient within $5\%$ of that prescribed. We have often encountered the situation that the area which have not only several irregular contours but also tissue heterogeneities should be treated. With conventional devices such as wedges, missing tissue compensator. there are some limitations to achieve the uniform dose distribution in treatment volume. The use of CT simulator, 3-D planning system, computer-controlled milling machine enables it to deliver the dose uniformally. This report includes the whole procedure which have patient data acquisition 3D planning, computer-controlled milling, performance verification of 3D compensator, and TLD evaluation. We applied it for the treatment of head and heck cancer only. In Spite of the irregular contour and different electron density of tessue, we have achieved the uniformity of the dose distribution within ${\pm}3\%$ relatively. Although there are some problems which are not only verification of performance but uncertainties of using the new treatment device, we believe that the improvement of dosimetry will eliminate the uncertainties of that application. so the other lesions besides head and neck can will be ale to use the 3D compensator to achieve the dose uniformity

  • PDF

Transmission Grating Formation in High Refractive-index Amorphous Thin Films Using Focused-Ion-Beam Lithography (접속이온빔 리소그라피를 이용한 고굴절 비정질 박막 투과 격자 형성)

  • Shin, Kyung;Kim, Jin-Woo;Park, Jeong-Il;Lee, Hyun-Yong;Lee, Young-Jong;Chung, Hong-Bay
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.1
    • /
    • pp.6-10
    • /
    • 2001
  • In this study, we investigated the optical properties of sub-wavelength a-Si thin film transmission gratings, especially the polarization effect, the phase difference and the birefringence by using linearly polarized He-Ne laser beam (632.8nm). The a-Si transmission grating of the thickness $of < 0.1 \mum$ with four-type period($\Lambda = 0.4 \mum and 0.6 \mum$ for sub-wavelength and $\Lambda = 1.0 \mum and 1.4 \mum$ for above-wavelength) on quartz substrates have been fabricated using 50 KeV Ga+ Focused-Ion-Beam(FIB) Milling and $CF_4$Reactive-Ion-Etching(RIE) method. Finally, we obtained the trating array of a-Si thin film with a period $0.4 \mum, 0.6 \mum, 1.0 \mum, 1.4 \mum$ which have nearly equal finger spacing and width, sucessfully. Especially, for gratings with $\Lambda = 0.6 \mum(linewidth=0.25 \mum, linespace=0.35\mum), the \etamax at \theta_в=17.0^{\circ}$ is estimated to be 96%. As the results, we believe that the sub-wavelength grating arrayed a-Si thin film has the applicability as the optical device and components.

  • PDF

High-$T_c$ 2nd-order SQUID Gradiometer for Use in Unshielded Environments (비차폐 환경에서의 고온초전도 SQUID 2차 미분기의 특성연구)

  • 박승문;강찬석;이순걸;유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.50-54
    • /
    • 2003
  • We have fabricated $∂^2$$B_{z}$ /$∂x^2$ type planar gradiometers and studied their properties in operation under various field conditions. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ (100) substrate by a pulsed laser deposition (PLD) system and patterned into a device by the photolithography with ion milling technique. The device consists of 3 pickup loops designed symmetrically Inner dimension and the width of the square side loops are 3.6 mm and 1.2 mm, respectively, and the corresponding dimensions of the center loop are 2.0 mm and 1.13 mm. The length of baseline gradiometer is 5.8 mm. Step-edge junction width is 3.0 $\mu\textrm{m}$ and the hole size of the SQUID loop is 3 $\mu\textrm{m}$ ${\times}$ 52 $\mu\textrm{m}$. The SQUID inductance is estimated to be 35 pH. The device was formed on a 20 mm ${\times}$ 10 mm substrate. We have tested the behavior of the device in various field conditions. The unshielded gradiometer was stable under extremely hostile conditions on a laboratory bench. Noise level 0.45 pT/$\textrm{cm}^2$/(equation omitted)Hz and 0.84 pT/$\textrm{cm}^2$/(equation omitted)Hz at 1 Hz for the shielded and the unshielded cases, which correspond to equivalent field noises of 150 fT/(equation omitted)Hz and 280 fT/(equation omitted)Hz, respectively. In spite of the short baseline of 5.8 mm, the high common-mode-rejection-ratio of the gradiometer, $10^3$, allowed us to successfully record magnetocardiogram of a human subject, which demonstrates the feasibility of the design in biomagnetic studies.

  • PDF