• 제목/요약/키워드: Midas IT

검색결과 140건 처리시간 0.04초

Evaluation of Construction RCB Exterior Wall Formwork according to Placing Height on Nuclear Power Plant

  • Song, Hyo-Min;Sohn, Young-Jin;Shin, Yoonseok
    • 한국건축시공학회지
    • /
    • 제15권6호
    • /
    • pp.653-660
    • /
    • 2015
  • Technologies for reducing construction duration are key factors in nuclear power plant construction projects, as a reduction in construction duration at the construction phase leads to a reduction in construction cost and an increase in profits through the early operation of the nuclear power plant. To analyze the constructability of the height of single-layer placement of formwork for the Reactor Containment Building (RCB) exterior wall through lateral pressure according to the height of concrete placement, the deformation criteria for formwork, and a new form design, 'MIDAS GEN (hereinafter referred to as MIDAS)' is used in this study. The cost and workload of formwork are derived according to the unit of height of the RCB exterior wall. Based on the result, it was found that the higher the RCB exterior wall, the higher the material cost, and the less the construction duration and the less the total number of formwork layers. Based on this result, it is believed that the material cost and the construction duration can be appropriately determined according to the formwork height.

지속 가능한 구조설계 정보의 인터페이스 모듈 개발 (A Development of Sustainable Interface Module for the Structural Design Information)

  • 엄진업;신태송
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.509-518
    • /
    • 2013
  • 본 연구는 지속가능한 구조설계 정보의 인터페이스 모듈의 개발에 관한 것으로 구조해석 S/W인 Midas/Gen과 BIM S/W인 Tekla Structures를 대상으로 한다. 모듈의 개발은 기존 연구의 내용을 근간으로 기능과 적용성을 개선하였다. 기존 연구에서 모델 정보를 양방향으로 교환하는데 있어 기능적으로 문제가 없었지만, 구조해석모델과 실시설계 모델의 특성 차이로 적용성이 제한적이고 일회적이라는 문제점을 가지고 있었다. 본 연구에서는 기존 연구에서 발생하는 문제점을 분석하고, 그에 대한 해결책을 제시하였으며, 이를 반영하여 인터페이스 모듈의 적용성을 개선하고자 하였다.

『상한론(傷寒論)』 변병진단체계(辨病診斷體系)에 근거하여 오수유탕(吳茱萸湯)을 투여한 편두통 증례 및 하지불안증후군 증례 각 1례 (A Case Report of migraine and a case report of restless legs syndrome treated with Osuyu-tang based on Shanghanlun Provisions)

  • 허주;이욱제;정재원
    • 대한상한금궤의학회지
    • /
    • 제11권1호
    • /
    • pp.125-138
    • /
    • 2019
  • Objective : This study was intended to evaluate if treatment with Osuyu-Tang following the disease pattern identification diagnostic system based on Shanghanlun provisions (DPIDS) worked analyzing the progress of patients with migraine and restless legs syndrome and to reinterpret the provision of 309 Soyinbing Osuyu-Tang based on the analysis of whether it worked. Methods : Two cases treated with Soyinbing Osuyu-Tang were analyzed using DPIDS. The migraine and restless legs syndrome in both cases were evaluated using the migraine disability assessment (MIDAS) and the Korean versions of the international restless legs scale (K-IRLS), respectively. Results : In the first case, during 45 days of treatment, the MIDAS decreased from 10 days to 3 days. In the second case, during 30 days of treatment, the K-IRLS decreased from 30 to 9. In both cases, Soyinbing was associated with the disease, although the activity was less; and Leng (冷) was associated with numbness in the kneeling position. Conclusions : It was confirmed that treatment with Osuyu-Tang was effective against migraine and restless legs syndrome and that Leng could be associated with numbness in the kneeling position. The etymological analysis of the Shanghanlun characters suggested the possibility of further clarifying the clinical significance and interpretation of Shanghanlun.

Performance of pre-treatment 18F-fluorodeoxyglucose positron emission tomography/computed tomography for detecting metastasis in ovarian cancer: a systematic review and meta-analysis

  • Han, Sangwon;Woo, Sungmin;Suh, Chong Hyun;Lee, Jong Jin
    • Journal of Gynecologic Oncology
    • /
    • 제29권6호
    • /
    • pp.98.1-98.13
    • /
    • 2018
  • Objective: We describe a systematic review and meta-analysis of the performance of ${18}F$-fluorodeoxyglucose ($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) for detecting metastasis in ovarian cancer. Methods: MEDLINE and Embase were searched for diagnostic accuracy studies that used $^{18}F-FDG$ PET or PET/CT for pre-treatment staging, using surgical findings as the reference standard. Sensitivities and specificities were pooled and plotted in a hierarchic summary receiver operating characteristic plot. Potential causes of heterogeneity were explored through sensitivity analyses. Results: Eight studies with 594 patients were included. The overall pooled sensitivity and specificity for metastasis were 0.72 (95% confidence interval [CI]=0.61-0.81) and 0.93 (95% CI=0.85-0.97), respectively. There was considerable heterogeneity in sensitivity ($I^2=97.57%$) and specificity ($I^2=96.74%$). In sensitivity analyses, studies that used laparotomy as the reference standard showed significantly higher sensitivity and specificity (0.77; 95% CI=0.67-0.87 and 0.96; 95% CI=0.92-0.99, respectively) than those including diagnostic laparoscopy (0.62; 95% CI=0.46-0.77 and 0.84; 95% CI=0.69-0.99, respectively). Higher specificity was shown in studies that confirmed surgical findings by pathologic evaluation (0.95; 95% CI=0.90-0.99) than in a study without pathologic confirmation (0.69; 95% CI=0.24-1.00). Studies with a lower prevalence of the FDG-avid subtype showed higher specificity (0.97; 95% CI=0.94-1.00) than those with a greater prevalence (0.89; 95% CI=0.80-0.97). Conclusion: Pre-treatment $^{18}F-FDG$ PET/CT shows moderate sensitivity and high specificity for detecting metastasis in ovarian cancer. With its low false-positive rate, it can help select surgical approaches or alternative treatment options.

와렌 트러스 설계에의 신경망 적용에 관한 연구 (A Study on Adaptation of Neural Network to Warren Truss Design)

  • 신동철;이승창;조영상
    • 한국강구조학회 논문집
    • /
    • 제15권4호통권65호
    • /
    • pp.413-422
    • /
    • 2003
  • 구조 설계를 위해 초기 부재를 가정할 때나 건축 실무에서 개산 견적을 계산할 때 기술자의 직관이나 비슷한 조건의 기존 설계 평균값을 사용하고 있으나 설계 조건은 모두 다르기 때문에 큰 오차가 발생할 수밖에 없다. 이러한 문제점을 해결하기 위해서 확률론적인 절차가 내재되어 있어 불확실성을 다룰 수 있는 인공 신경 회로망의 이용하여 와렌 트러스를 설계하므로써 적용성을 평가하였다. 제안된 신경망 설계변수값와 구조설계 단계에 따라 다양한 와렌 트러스를 설계하여 MIDAS 프로그램 설계결과의 10% 오차 이내로 근사 설계를 하므로써 모델의 타당성을 검증하였다. 제안된 모델은 약간의 오차를 포함하지만 적은 시간과 노력으로 신뢰할 수 있는 설계 결과를 얻을 수 있으며, 부재 테이블을 사용하는 비선형 관계의 구조설계에도 적용 가능한 특성을 가지고 있다.

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.

반강접 접합부를 갖는 강골조의 거동에 대한 해석적 연구 (An Analytical Study on the Behavior of Steel Frames with Semi-Rigidity of Beam-to-Column Connections)

  • 김종성
    • 한국강구조학회 논문집
    • /
    • 제15권5호통권66호
    • /
    • pp.551-559
    • /
    • 2003
  • 강골조의 보-기둥 접합부에 대한 해석과 설계는 일반적으로 완전한 강접이나 마찰이 없는 완전한 핀접합으로 가정하는 것이 보통이다. 이러한 경우, 구조해석 및 설계과정을 단순화시키는 장점은 있으나, 실제 철골 접합부에서는 작용하중에 대하여 어느 정도의 모멘트 전달과 회전구속력을 갖는 반강접으로 해석해야 하므로 실제와는 다소 차이가 날 수 있다. 이에, 본 연구에서는 고정계수에 의한 기둥-보 접합부의 반강접성과 P-delta효과를 고려한 골조의 비선형 해석 프로그램을 작성하고, 수치해석을 통해 평면 강골조의 변형과 내력에 미치는 접합강성의 영향을 검토하였으며, 상용의 해석프로그램인 MIdas Gen과 비교하였다.

온실 생육환경 및 제어정보 데이터베이스 개발 (Development of Database for Environment and Control Information in Greenhouse)

  • 공대광;류관희;진제용
    • Journal of Biosystems Engineering
    • /
    • 제28권1호
    • /
    • pp.59-64
    • /
    • 2003
  • This study was carried out to develop database system using internet fur greenhouse. The database system consisted of group monitor, client monitor. server monitor and DBMS. The results of the study are summarized as follows. 1. The monitoring module, as data collection system for database. could monitor the state of the control device and the greenhouse environment. 2 The group monitor was connected to the house monitors by RS-485 communication method. Data received by the group monitor were sent to the server monitor and then stored in database server by TCP/IP and MIDAS. 3. The data of database consisted of on growing environment. control devices, operation and cultivation data in greenhouse. It was developed using MS-SQL server. 4. Remote monitoring of greenhouse was realized in a client/server environment. The client module. which was named as the client monitor. made requests to access the measurement data of greenhouse through the remote data module of the server monitor in internet environment.

기둥 복합댐퍼의 해석모델 구축 및 기존 건축물에 대한 내진보강 효과분석 (Analytical Modelling of Column-Type Hybrid Damper and Seismic Rehabilitation of Existing Buildings)

  • 최기선;유영찬;김긍환;조해진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.285-288
    • /
    • 2008
  • 본 연구에서는 도심지 건축물의 개조 재활용을 위한 핵심 보강기술의 개발을 위하여 기존 건축물의 내진보강을 위한 새로운 개념의 기둥복합댐퍼를 제안하고, 그 적용 가능성을 타진하기 위한 해석적 연구를 수행하였다. 이를 위하여 먼저 기둥복합댐퍼의 이력특성을 고려할 수 있는 해석모델을 구축하고, 상용화 구조해석 프로그램(MIDAS-Gen)에 적용할 수 있는 모델링 기법을 개발하였다. 이와 같이 개발된 기둥복합댐퍼를 이용하여 수직증축을 상정한 기존 건축물의 내진보강을 실시하고 개발된 해석모델링 기법을 적용하여 시간이력해석에 의해 보강 전/후의 효과를 검토하였다. 본 구조해석 결과에 의하면, 기둥복합댐퍼의 보강에 의해 보강되지 않은 구조물에 비하여 밑면전단력이 약 20% 정도 감소하였으며, 임계층에서의 층간변위가 20% 정도 감소하는 결과를 얻을 수 있었다.

  • PDF