• Title/Summary/Keyword: Microwave generation

Search Result 96, Processing Time 0.022 seconds

Microwave Orbital Angular Momentum Mode Generation and Multiplexing Using a Waveguide Butler Matrix

  • Lee, Wangjoo;Hong, Ju Yeon;Kang, Min Soo;Kim, Bong Su;Kim, Kwang Seon;Byun, Woo Jin;Song, Myung Sun;Cho, Yong Heui
    • ETRI Journal
    • /
    • v.39 no.3
    • /
    • pp.336-344
    • /
    • 2017
  • In this paper, we propose a convenient microwave orbital angular momentum (OAM) mode generation and multiplexing method operating in the 18 GHz frequency band, based on a $2{\times}2$ uniform circular array and a $4{\times}4$ Butler matrix. The three OAM modes -1, 0, and +1 were generated and verified using spatial S-parameter measurements; the measured back-to-back mode isolation was greater than 17 dB in the full 17 GHz to 19 GHz range. However, the radiated OAM beam centers were slightly dislocated and varied with both frequency and the mode index, because of the non-ideal characteristics of the Butler matrix. This resulted in mode isolation degradation and transmission distance limitations.

Technological Trends of C-/X-/Ku-band GaN Monolithic Microwave Integrated Circuit for Next-Generation Radar Applications (차세대 레이더용 C-/X-/Ku-대역 GaN 집적회로 기술 동향)

  • Ahn, H.K.;Lee, S.H.;Kim, S.I.;Noh, Y.S.;Chang, S.J.;Jung, H.U.;Lim, J.W.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.5
    • /
    • pp.11-21
    • /
    • 2022
  • GaN (Gallium-Nitride) is a promising candidate material in various radio frequency applications due to its inherent properties including wide bandgap, high carrier concentration, and high electron mobility/saturation velocity. Notably, AlGaN/GaN heterostructure field effect transistor exhibits high operating voltage and high power-density/power at high frequency. In next-generation radar systems, GaN power transistors and monolithic microwave integrated circuits (MMICs) are significant components of transmitting and receiving modules. In this paper, we introduce technological trends for C-/X-/Ku-band GaN MMICs including power amplifiers, low noise amplifiers and switch MMICs, focusing on the status of GaN MMIC fabrication technology and GaN foundry service. Additionally, we review the research for the localization of C-/X-/Ku-band GaN MMICs using in-house GaN transistor and MMIC fabrication technology. We also discuss the results of C-/X-/Ku-band GaN MMICs developed at Defense Materials and Components Convergence Research Department in ETRI.

Technical Status of Microwave Remote Sensing of Tropical Cyclones (열대저기압 마이크로파 원격탐사의 기술 현황)

  • Choi, Geun-Chul;Yang, Chan-Su;Pack, Han-Il
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.193-199
    • /
    • 2006
  • This article reviews several microwave instruments employed in observation and analysis of tropical cyclones (TCs), typhoon, and hurricanes. Microwave signals are useful for observing tropical cyclones with severe storms since it isn't severely absorbed by the clouds and rain in the storm. The instruments discussed include scatterometers, microwave radiometers, synthetic aperture radars (SARs), and rain radar from space. The date such as winds, rainfall and cloud-distribution in the TCs obtained by microwave instruments provide important informations for forecasting the intensity and path of the typhoon. For example, there're wind-distribution provided by SSM/I which has a wide swath, detailed wind fields from ERS-1, 2 scatterometers and RADARSAT-1 SAR and TRMM's rain radar pro 떠 ding high resolution. Operational satellite instruments lunched recently have improved upon the problems of low resolution and narrow swath indicated at the beginning microwave remote sensing. Understanding and practical using sufficiently about the microwave instruments will serve for searching the features such as generation and development of the TCs.

  • PDF

An optimized microwave-assisted extraction method for increasing yields of rare ginsenosides from Panax quinquefolius L.

  • Yao, Hua;Li, Xuwen;Liu, Ying;Wu, Qian;Jin, Yongri
    • Journal of Ginseng Research
    • /
    • v.40 no.4
    • /
    • pp.415-422
    • /
    • 2016
  • Background: Rare ginsenosides in Panax quinquefolius L. have strong bioactivities. The fact that it is hard to obtain large amounts of rare ginsenosides seriously restricts further research on these compounds. An easy, fast, and efficient method to obtain different kinds of rare ginsenosides simultaneously and to quantify each one precisely is urgently needed. Methods: Microwave-assisted extraction (MAE) was used to extract nine kinds of rare ginsenosides from P. quinquefolius L. In this article, rare ginsenosides [20(S)-Rh1, 20(R)-Rh1, Rg6, F4, Rk3, 20(S)-Rg3, 20(R)-Rg3, Rk1, and Rg5] were identified by high performance liquid chromatography (HPLC)-electrospray ionization-mass spectrometry. The quantity information of rare ginsenosides was analyzed by HPLC-UV at 203 nm. Results: The optimal conditions for MAE were using water as solvent with the material ratio of 1:40 (w/v) at a temperature of $145^{\circ}C$, and extracting for 15 min under microwave power of 1,600 W. Seven kinds of rare ginsenosides [20(S)-Rh1, 20(R)-Rh1, Rg6, F4, Rk3, Rk1, and Rg5] had high extraction yields, but those of 20(S)-Rg3 and 20(R)-Rg3 were lower. Compared with the conventional method, the extraction yields of the nine rare ginsenosides were significantly increased. Conclusion: The results indicate that rare ginsenosides can be extracted effectively by MAE from P. quinquefolius L. in a short time. Microwave radiation plays an important role in MAE. The probable generation process of rare ginsenosides is also discussed in the article. It will be meaningful for further investigation or application of rare ginsenosides.

Analysis of selenium in oil refinery wastewater by hydride generation atomic absorption spectrometry (Hydride Generation Atomic Absorption Spectrometry를 이용한 석유정제폐수중의 selenium 분석)

  • Cheon, Mi-Hee;Kim, Chul;Lee, Hyun-Joo;Kang, Lim-Seok
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.399-406
    • /
    • 2003
  • This study was conducted to find out the analysis condition of selenium(Se) in oil refinery wastewater with a high concentration of Se using the atomic absorption spectrometry with hydride generation system (HG-AAS). From various experiments that reduced Se(VI) to Se(IV), the optimum pretreatment condition was determined to be a sample volume of 10 mL, HCl 10 mL, with a 30 min heating time in a water bath. In oil refinery wastewater, as the concentration of organics and constitution became higher, the recovery rates of Se decreased. Therefore, three acid digestion methods ($HNO_3/HClO_4$ digestion, $KMnO_4$ digestion, and microwave acid digestion) were tested on the recovery rates of Se in reference to the digestion of organics, petroleum and oxidation from organic Se(org.), Se(IV) to Se(VI). The experiment results showed that the average recovery rate of Se was the highest in microwave acid digestion, although all of the digestions were more than 90%. In consequence, the pretreatment procedure of microwave digestion followed by HCl addition was the most suitable for selenium analysis in oil refinery wastewater by using HG-AAS.

Study on the Etching Characteristics of $0.2\mu\textrm{m}$ fine Pattern of Ta Thin film for Next Generation Lithography Mask (차세대 노광공정용 Ta박막의 $0.2\mu\textrm{m}$ 미세패턴 식각특성 연구)

  • Woo, Sang-Gyun;Kim, Sang-Hoon;Ju, Sup-Youl;Ahn, Jin-Ho
    • Korean Journal of Materials Research
    • /
    • v.10 no.12
    • /
    • pp.819-824
    • /
    • 2000
  • In this research, the etching characteristics of Ta thin film with chlorine plsama have been studied by Electron Cyclotron Resonance (ECR) plasma etching system. The effects of microwave power, RF bias power, working pressure and gas chemistry on the etching profiles have been investigated. The microloading effect, which was observed at fine pattern formation, was effectively suppressed by double step etching, and anisotropic $0.2{\mu\textrm{m}}$ L&S patterns were successfully generated.

  • PDF

Design of a 2.5 Gbps CMOS optical transmitter with 10:1 serializer using clock generation method (Reference clock 생성기를 이용한 10:1 데이터 변환 2.5 Gbps 광 송신기 설계)

  • Kang, Hyung-Won;Kim, Kyung-Min;Choi, Young-Wan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.159-165
    • /
    • 2005
  • The proposed optical transmitter is composed of FF(flip flop) , PLL (phase locked loop), reference clock generator, serializer and LD driver 10x250 Mb/s data arrays are translated to the 2.5 Gb/s data signal by serializer. In this case, 1 data bus is allocated usually as a reference clock for synchronization. In this proposed optical transmitter, 125 MHz reference clock is generated from 10x250 Mb/s data arrays by reference clock generator. From this method. absent of reference clock bus is available and more data transmission become possible. To achieve high speed operation, the serializer circuit is designed as two stacks. For 10:1 serialization, 10 clocks that have 1/10 lambda differences is essential, so the VCO (voltage controlled oscillator) composed of 10 delay buffers is designed. PLL is for runing at 250 MHz, and dual PFD(phase frequency detector) is adopted for fast locking time. The optical transmitter is designed by using 0.35 um CMOS technology.

  • PDF

Brightness Temperature Retrieval using Direct Broadcast Data from the Passive Microwave Imager on Aqua Satellite

  • Kim, Seung-Bum;Im, Yong-Jo;Kim, Kum-Lan;Park, Hye-Sook;Park, Sung-Ok
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.1
    • /
    • pp.47-55
    • /
    • 2004
  • We have constructed a level-1 processor to generate brightness temperatures using the direct-broadcast data from the passive microwave radiometer onboard Aqua satellite. Although 50-minute half-orbit data, called a granule, are being routinely produced by global data centers, to our knowledge, this is the first attempt to process 10-minute long direct-broadcast (DB) data. We found that the processor designed for a granule needs modification to apply to the DB data. The modification includes the correction to path number, the selection of land mask and the manipulation of dummy scans. Pixel-to-pixel comparison with a reference indicates the difference in brightness temperature of about 0.2 K rms and less than 0.05 K mean. The difference comes from the different length of data between 50-minute granule and about 10-minute DB data. In detail, due to the short data length, DB data do not always have correct cold sky mirror count. The DB processing system is automated to enable the near-real time generation of brightness temperatures within 5 minutes after downlink. Through this work, we would be able to enhance the use of AMSR-E data, thus serving the objective of direct-broadcast.

Generation of Non-uniform Meshes for Finite-Difference Time-Domain Simulations

  • Kim, Hyeong-Seok;Ihm, In-Sung;Choi, Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.128-132
    • /
    • 2011
  • In this paper, two automatic mesh generation algorithms are presented. The methods seek to optimize mesh density with regard to geometries exhibiting both fine and coarse physical structures. When generating meshes, the algorithms attempt to satisfy the conditions on the maximum mesh spacing and the maximum grading ratio simultaneously. Both algorithms successfully produce non-uniform meshes that satisfy the requirements for finite-difference time-domain simulations of microwave components. Additionally, an algorithm successfully generates a minimum number of grid points while maintaining the simulation accuracy.