• 제목/요약/키워드: Microvalve

검색결과 23건 처리시간 0.03초

적층 벤더형 압전 액추에이터 마이크로 밸브 (Microvalve with multilayer Bender Type PZT Actuator)

  • 윤소남;이경우;윤석진;박중호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.250-253
    • /
    • 2004
  • This study deals with the microvalve, which is composed of the multilayer bender type PZT actuator, actuator controller and microvalve body. The object of this study is to develope the microvalve with multilayer bender type PZT actuator. In order to achieve this object, prototype PZT actuator and microvalve were suggested and manufactured. Also, the performance of this model was evaluated through the experiments.

  • PDF

자성유체의 온도에 따른 점성 변화를 이용한 미소 유체 소자 (The Microfluidic Device using Viscosity Deviation of Magnetic Fluids Due to Temperature Changes)

  • 최범규;오재근;안정재
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.473-478
    • /
    • 2004
  • This study focused on the charateristic of magnetic fluids, the viscosity deviation of magnetic fluids due to temperature changes, and fabrication of a 'purely' liquid type microvalve. The viscosity of magnetic fluids decreases sharply during increasing of temperature. The viscosity of magnetic fluids is rated 1,000 cP at the room temperature and 25 cP when the temperature reaches $100^{\circ}C$. Briefly, it is remarkable that the fluid flow can be controlled by the temperature and this characteristic can be adopted to the microfluidics as a microvalve. The fabrication of a liquid type microvalve is more easy than solid state microvalves and which can increase an efficiency of the controlability with respect to the thermo-pneumatic micropump which is studied broadly for many years. When the magnetic fluid used as a sealant for high level sealing, the pressure leakage is less than solid state microvalve. The experimental results show that the pressure drop in microchannel, filled with the magnetic fluid, is significant in the temperature range of $20^{\circ}C{\sim}50^{\circ}C$ and this result explains why the use of magnetic fluids is possible as a microvalve searcher uses this characteristics. Well known thermo-pnumatic.

유한요소법을 이용한 버클링 마이크로 밸브의 유동특성 해석 및 최적 설계 (Analysis of Flow Characteristics and Optimum Design of a Buckling Microvalve Using the Finite Element Method)

  • 김재민;이종춘;정귀상;윤석진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.383-386
    • /
    • 2002
  • This paper reports on the fluid flow simulation results of an active microvalve. The mechanical and fluidic analysis are done by finite element method. The designed structure is normally closed microvalve using buckling effect, which is consist of three separate structures; a valve seat die, an actuator die and a small piezoelectric actuator. It is confirmed that the complete laminar flow and the lowest flow leakage are strongly depend on the valve seat geometry. In addition, turbulent flow was occurs in valve outlet according to increase seat dimension, height and inlet pressure. From this, we was deducts the optimum geometry of the valve seat and diaphragm deflection that have an great influence fluid flow in microvalve. Thus, it is expected that our simulation results would be apply for constructing integrated chemical analyzing system or drug delivery system.

  • PDF

열공압 방식의 Polydimethylsiloxane 마이크로 밸브의 제작 및 특성 (Fabrication and Characteristics of Thermopneumatic-Actuated Polydimethylsiloxane Microvalve)

  • 김진호;조주현;한경희;김영호;김한수;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권4호
    • /
    • pp.231-236
    • /
    • 2004
  • A normally open thermopneumaticc-actuated microvalve has been fabricated and their properties are investigated. The advantages of the proposed microvalve are of the low cost fabrication process and the transparent optical property using polydimethylsiloxane (PDMS) and indium tin oxide (ITO) glass. The fabricated microvalves with in-channel configuration are easily integrated with other microfluidic devices on the same substrate. The fabrication process of thermopneumatic-actuated microvalvesusing PDMS is very simple and its performance is very suitable for a disposable lab-on-a-chip. The PDMS membrane deflection increases and the flow rates of the microchannel with microvalvels decrease as the applied power to the ITO heater increases. The powers at flow-off are dependent on the membrane thickness and the applied inlet pressure but are independent of the channel width of microvalves. The flow rate is well controlled by the switching function of ITO heater and the closing/opening times are around 20 sec and 25 sec, respectively.

A Study on the Passive Microvalve Applicable to Drainage Device for Glaucoma

  • Sim, Tae-Seok;Kim, Yong-Kweon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권4호
    • /
    • pp.253-258
    • /
    • 2002
  • This paper reports the design, modeling, fabrication and measurement of passive microvalves, which are applicable to glaucoma implants. The proposed microvalves were designed using fluidic theory. The microvalves consisted of microchannels and chambers. The microchannels had a constant fluidic resistance generating a pressure difference. Six kinds of microvalves were designed using fluidic equations for laminar flow and fabricated to examine the influences of chamber size, channel length and the shape of channel cross section. The pressure difference between the designed microvalve and the fabricated microvalve was measured to be less than 4%.

버클링 마이크로 적층형 압전밸브의 제작 (Fabrication of a buckling micro MCA valve)

  • 이종화;정귀상
    • 센서학회지
    • /
    • 제15권1호
    • /
    • pp.47-52
    • /
    • 2006
  • This paper describes the design, fabrication and characteristics of a buckling microvalve using a MCA (multilayer ceramic actuator). The mechanical and fluidic analysis are done by finite element method. The designed structure is normally closed microvalve using buckling effect, which is consist of three separate structures; a valve seat die, an actuator die and a small piezoelectric actuator. The flow rate of the fabricated MCA valve was 0-8.13 ml/min at the applied pressure of 0-50 kPa. Maximum non-linearity was 2.24 % FS at a duty cycle of 50 %. The maximum pressure was 230 kPa and the leak rate was $3.03{\times}10^{-8}\;Pa{\cdot}m^{3}/cm^{2}$ at a supply voltage of 100 V.

약물 전달용 전자력 마이크로 밸브의 설계 및 제작 (Design, Fabrication of Electromagnetic Microvalve for Drug Delivery Systems)

  • 임인호;이기정;윤현중;심우영;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1526-1527
    • /
    • 2007
  • This paper presents the design, fabrication and experimental results of an electromagnetic microvalve for drug delivery systems. The microvalve consists of two silicon substrates with a silicone rubber diaphragm and a flow channel, a PDMS layer, and an electromagnetic actuator. Each substrate is fabricated by using the silicon wet etch, SU-8 mold process and $O_2$ plasma bonding.

  • PDF

ZnO 압전박막의 제조와 유량조절밸브로서의 응용 (ZnO Piezoelectric Thin Film Fabrication and Its Application as a Flow-rate Control Microvalve)

  • 박세광
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1989년도 춘계학술대회 논문집
    • /
    • pp.66-69
    • /
    • 1989
  • After reviewing previous work done on two piezoelectric thin films(PZT, ZnO), ZnO thin piezofim of 1-3UM is fabricated by sputtering on the different substrates(i. e., P+Si/N-Si, SiO2/P+Si/ N-Si, Al/SiO2/ P+Si/ N+Si). The result shows that ZnO piezofilm on the Al has the best c-axis orientation. One of applications for the ZnO piezofilm as an microvalve to control liquid flow is introduced, and which can be controlled electrically and remotely.

  • PDF

Continuous Production of Immunoliposomes using a Microvalve-controlled Microfluidic Device (μFD)

  • Jin, Yan;Kim, So Hyun;Kim, Myunghee;Park, Sungsu
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권10호
    • /
    • pp.2921-2924
    • /
    • 2013
  • Immunoliposomes (antibody-conjugated liposomes) are highly useful as both a drug carrier in drug delivery and as a reporting probe in immunodiagnostics. However, antibody conjugation is lengthy and cumbersome, because this includes several steps such as derivatization of the antibody, conjugation of the derivatized antibody to liposomes, and separation of the unbound antibodies from immunoliposomes. Recently, liposome preparation steps have simplified by using microfluidic devices (${\mu}FDs$) where liposomes are formed when a stream of lipids in solvent is hydrodynamically focused between two oblique buffer streams in a microchannel. Herein, we report a simple method for the production of immunoliposomes (rabbit IgG-conjugated liposomes) using microvalve-controlled ${\mu}FD$. The presence of antibody on the liposome was verified by observing the binding of immunoliposomes to rabbit IgG on the surface. The results suggest that immunoliposomes can be easily prepared through sequential mixing of antibody, conjugation reagents, preformed liposomes using microvalve-controlled ${\mu}FD$.