• 제목/요약/키워드: Microscopic test

검색결과 527건 처리시간 0.029초

골수내천공을 동반한 골유도재생술시 법랑기질유도체의 효과 (Effect of Enamel Matrix Derivative on Guided Bone Regeneration with Intramarrow Penetration)

  • 이영종;박준봉;권영혁;허익;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제34권2호
    • /
    • pp.393-410
    • /
    • 2004
  • The purpose of this study was to investigate effect of enamel matrix derivative on guided bone regeneration with intramarrow penetration in rabbits. Eight adult male rabbits (mean BW 2Kg) were used in this study. Intramarrow penetration defects were surgically created with round carbide bur(HP long #6) on calvaria of rabbits. Defects were assigned to the control group grafted with mixture of the same quantity of demineralized freeze-dried bone allograft and deproteinized bovine bone mineral. Then, guided bone regeneration was carried out using resorbable membrane and suture. Enamel matrix derivative applied to defects was assigned to the test group. And treated as same manners as the control group. At 1, 2, 3 and 8 weeks after the surgery, animals were sacrificed, specimens were obtained and stained with Hematoxylin-Eosin for light microscopic evaluation. The results of this study were as follows : 1. At 1, 2 and 3 weeks, no differences were observed between the control group and the test group in the aspect of bone formation around bone graft. 2. Proliferation of blood capillary was faster in the test group than in the control group. 3. Bone regeneration in intramarrow penetration was faster in the test group than in the control group. 4. At 8 weeks, new osteoid tissue formation around bone graft was more prominent in the test group than in the control group. From the above results, enamel matrix derivative might be considered as the osteopromotion material and effective in the guided bone regeneration with intramarrow penetration.

광섬유 FBG센서를 이용한 원주형 구조물의 2차원 상대변위 모니터링기법 개발 (Development of a Convergence Monitoring Method for Cylindrical Structures by Optical Fiber Bragg Grating Sensor)

  • 노병철;김종우;강석화
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.160-166
    • /
    • 2006
  • 본 연구에서는 광섬유 FBG 센서를 이용, 곡률반경을 고려한 이 방향 변위(Two-Way Displacement)를 측정하여 변형각을 환산함으로써 상대좌표를 구하는 알고리즘을 정립하였으며 이를 이용하면 작은 변형에 대해서도 매우정확하게 상대변위를 구할 수 있음을 알 수 있었다. 이를 확인하기 위해 4.5m높이의 H형강에 고안된 이 방향 광섬유센서를 부착하여 횡 방향으로 외력을 가해서 발생한 변위를 수준측량과 일반적인 전자식 변위계로 동시에 측정하여 각각의 측정성능을 비교분석하였다. 그 결과, 광섬유센서의 분해능은 다른 센서시스템에 비해 월등하였으며 이차원 상대좌표의 측정이 가능함을 확인하였다.

인산화 전분 ER 유체의 댐퍼 내구 특성 (Durability of Phosphorated Starch Based Electrorheological Fluids in Damper Application)

  • 이철희;장민규;손정우;한영민;최승복
    • Tribology and Lubricants
    • /
    • 제25권5호
    • /
    • pp.285-291
    • /
    • 2009
  • In this work, durability characteristics of electrorheological (ER) fluid for damper application are experimentally investigated. ER fluid is prepared by using phosphorated starch particles and silicone oil. The field-dependent Bingham characteristics and response time for the proposed ER fluids are experimentally obtained. Experimental apparatus of durability test for ER fluid is established with cylindrical ER cylinder for mid-sized passenger vehicle. In order to evaluate the durability characteristics of ER fluid as a function of time, damping force and temperature variations are measured until one million cycles. After durability test, Bingham characteristics and response time of ER fluid are measured and compared to the initial properties. Microscopic pictures of ER fluid are taken to validate the changes of properties. The results indicate that the ER fluid can be commercially utilized in vehicle damper system with its durability performance. Moreover, the understanding of durability characteristics is essential to predict the service life of ER fluid as well as to design its applications.

편향각과 전단각이 탄소섬유/에폭시 평직 복합재료의 압축특성에 미치는 영향 (The Effect of Bias and Shear Angles on Compressive Characteristics of Carbon/Epoxy Plain Weave Fabrics)

  • 김성집;장승환
    • 대한기계학회논문집A
    • /
    • 제30권7호
    • /
    • pp.857-864
    • /
    • 2006
  • Various compressive specimens were fabricated using autoclave do-gassing moulding to find out the compressive characteristics of the carbon/epoxy plain weave fabric composites with respect to the bias and shear angles. The stacking angles of the bias specimens are $[0]_{10T,}\;[3]_{10T,}\;[6]_{10T,}\;[9]_{10T,}\;[12]_{10T,}\;[15]_{10T,}\;[30]_{10T,}\;[45]_{10T}$ and those of the sheared specimens are $[{\pm}37]_{10T,}\;[{\pm}32]_{10T,}\;[{\pm}28]_{10T,}\;[{\pm}22]_{10T,}$ respectively. In order to verify the effect of micro-tow structures on compressive strength and modulus of the composites, compressive test specimens of uni-directional carbon/epoxy composites with the same materials and the same stacking conditions were fabricated. The modulus and strength of both types of composite specimens were compared with the prediction results based on the CLPT and a proposed strength formula. The tow deformation and fracture modes were investigated by microscopic observation.

Radiation effect on peri-implant tissue after implantation

  • Kweon, Hyeog-Sin;Song, Kwang-Yeob
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.291-309
    • /
    • 2000
  • Statement of problem. There were several studies on the effects of irradiation to peri-implant bone tissue. However, no clear biological effect of irradiation on peri-implant bone tissue was reported yet. Purpose. This study compared the effect of irradiation on the surrounding tissue of a HA-coated implant fixture with controls. Material and methods. 6 Steri-Oss implants were implanted into the femur of 6 mongrels. The implanted dogs were divided into three groups and received irradiation. After 1 month, 2months and 4 months healing period, the histologic examination and mobility test and digital radiographic imaging analyses were performed to compare the control and experimental group respectively. Results. The irradiated group showed slower healing than control group in light microscopic observations. The mobility test demonstrated significant less number (Periotest) in control group than that of irradiated groups. The digital radiographic imaging analysis showed that the bone density of irradiated group was higher than control group. Conclusion. Generally, control group showed favorable biological response and less mobility than irradiated group. The conflict result of bone density value were measured by the digital radiographic imaging analysis. The digital radiographic imaging analysis needs more research in future.

  • PDF

국내에서 분리된 Borrelia burgdorferi Sensu Lato의 병원성 연구 (Study on Pathogenicity of Borrelia burgdorferi Sensu Lato Isolated in Korea)

  • 박경희;임정아;김종현;박의우
    • 대한미생물학회지
    • /
    • 제34권5호
    • /
    • pp.471-478
    • /
    • 1999
  • Spirochetes were isolated from the midgut of Ixodes persulcatus ticks captured at Chungju, Korea and identified as Borrelia afzelii strains by polymerase chain reaction. To determine the pathogenicity of the B. afzelii strains isolated in Korea, the microbiological and pathological features of Lyme disease were observed in C3H/He mice after intraperitoneal inoculation of the fresh isolate of B. afzelii strain. The results are summarized as follows 1) The Borrelia were detected in the tissues of heart, spleen, kidney, urinary bladder and knee joint within 7 days after inoculation of infection by dark field microscopic examination. The isolation rate from heart, urinary bladder and joint was significantly higher than the rate from spleen, kidney, and blood samples. 2) The Borrelia was detected in heart muscle by indirect immunofluorescent antibody test. 3) Antibody to the Borrelia was detected as early as one week after inoculation. 4) The marked tropism of the Borrelia was observed in myocardial, urinary tract and joint tissue. The main pathological features are inflammation in tissues of heart, kidney, joint and urinary bladder. From these results, the Borrelia afzelii strain isolated in Korea were determined as pathogenic strain.

  • PDF

새로운 과립구 콜로니 자극인자(rhG-CSF) DA-3030의 국소자극성에 관한 연구 (Studies on Local Irritation of DA-3030, a new granulocyte colony stimulating factor)

  • 김옥진;안병옥;이순복;김원배;양중익
    • Biomolecules & Therapeutics
    • /
    • 제2권3호
    • /
    • pp.247-255
    • /
    • 1994
  • As a series of safety studies of DA-3030, a new rhO-CSF, its local irritancy was examined in the rabbits after the following treatment; application into the conjunctival sac of the eye(single), subcutaneous injection(single), intramuscular injection(single), and intravenous injection(8-day repeated). In addition, paravenous irritation of DA-3030 was investigated in mice. The results obtained were as follows. 1. In the result of ocular irritation test, 0.03% solution of DA-3030 could be considered as a non-irritating material. 2. The local irritation of DA-3030 by an injection of 0.5mι of its solution subcutaneously or intramuscularly was negligible and not so much different from that of saline. 3. In the vascular irritancy test, macro- and microscopic observations revealed that the irritating activity of DA-3030 in blood vessels was not different from that of saline when they were injected once a day into vein retroauricularis of rabbits for 8 days.4. The paravenous administration of DA-3030 did not induce any abnormal changes at injection sites except mild swelling in 1 mouse at 3 hours after injection which was thought to be due to slow absorption. The above-mentioned results suggest that DA-3030 has no irritating activity when injected through intravenous or subcutaneous route for clinical practice as 0.03% solution.

  • PDF

기계윤활 운동면의 작동상태 진단을 위한 마멸분 해석 (Analysis of Wear Debris for Machine Condition Diagnosis of the Lubricated Moving Surface)

  • 서영백;박흥식;전태옥
    • 대한기계학회논문집A
    • /
    • 제21권5호
    • /
    • pp.835-841
    • /
    • 1997
  • Microscopic examination of the morphology of wear debris is an accepted method for machine condition and fault diagnosis. However wear particle analysis has not been widely accepted in industry because it is dependent on expert interpretation of particle morphology and subjective assessment criteria. This paper was undertaken to analyze the morphology of wear debris for machine condition diagnosis of the lubricated moving surfaces by image processing and analysis. The lubricating wear test was performed under different sliding conditions using a wear test device made in our laboratory and wear testing specimen of the pin-on-disk-type was rubbed in paraffine series base oil. In order to describe characteristics of debris of various shape and size, four shape parameters (50% volumetric diameter, aspect, roundness and reflectivity) have been developed and outlined in the paper. A system using such techniques promises to obviate the need for subjective, human interpretation of particle morphology in machine condition monitoring, thus to overcome many of the difficulties in current methods and to facilitate wider use of wear particle analysis in machine condition monitoring.

TiN 코팅된 고속도강과 합금공구강의 마멸거동 (Wear Behavior of TiN Coatings Deposited on High Speed Steel and Alloy Tool Steel)

  • 김석삼;서창민;박준목
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.705-712
    • /
    • 1995
  • The wear characteristics and wear mechanisms in TiN coating deposited on high speed steel and alloy tool steel by ion plating were investigated. Pin on V-block wear tester was used for a wear test method. The specimen was composed of three kinds of high speed steel and alloy tool steel which had different hardness by changing the heat treating condition. Three kinds of coating thickness were also applied to each specimen. Microscopic observation of worn surfaces was made by SEM. The scratch test of coating surface by the ion plating showed that critical load to break the coating interface was greater than 50N. The critical load increased with both substrate hardness and coating thickness. The wear resistance of TiN coated high speed steel became 10 times greater than that of non-coated ones. SEM observation showed that leading edge of contact was compressive and trailing edge was under maximum tensile stress and then surface cracking broke out perpendicular to sliding direction.

Strength failure behavior of granite containing two holes under Brazilian test

  • Huang, Yan-Hua;Yang, Sheng-Qi;Zhang, Chun-Shun
    • Geomechanics and Engineering
    • /
    • 제12권6호
    • /
    • pp.919-933
    • /
    • 2017
  • A series of Brazilian tests under diameter compression for disc specimens was carried out to investigate the strength and failure behavior by using acoustic emission (AE) and photography monitoring technique. On the basis of experimental results, load-displacement curves, AE counts, real-time crack evolution process, failure modes and strength property of granite specimens containing two pre-existing holes were analyzed in detail. Two typical types of load-displacement curves are identified, i.e., sudden instability (type I) and progressive failure (type II). In accordance with the two types of load-displacement curves, the AE events also have different responses. The present experiments on disc specimens containing two pre-existing holes under Brazilian test reveal four distinct failure modes, including diametrical splitting failure mode (mode I), one crack coalescence failure mode (mode II), two crack coalescences failure mode (mode III) and no crack coalescence failure mode (mode IV). Compared with intact granite specimen, the disc specimen containing two holes fails with lower strength, which is closely related to the bridge angle. The failure strength of pre-holed specimen first decreases and then increases with the bridge angle. Finally, a preliminary interpretation was proposed to explain the strength evolution law of granite specimen containing two holes based on the microscopic observation of fracture plane.