• Title/Summary/Keyword: Microphone Signal

Search Result 249, Processing Time 0.029 seconds

DIRECTIVE HARMONIC WAVE DETECTING SYSTEM USING LINEAR MICROPHONE ARRAY (직선배열 Microphone에 의한 음원의 방향과 주파수의 분석 System)

  • CHANG J.;ABE M.;KIM C.;KIDO K.
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.13 no.4
    • /
    • pp.145-149
    • /
    • 1980
  • Various methods have been so far proposed to find out the directions and spectra of sound waves from the sources for provisions of noise controls. The conventional methods are generally classified into three systems such as, single microphone system, moving microphone system and multi-microphone system, which composes a resultant super directivity by giving a appropriate delay and a weighting coefficient in the output of each microphone. In case of using a single microphone there is a difficulty in providing it with desirable super directivity in the low frequency range, while in case of using multi-microphone system there has been a disadvantage that the measurement of directivity could not separately be done with the spectrum analysing. And in case of the use of a moving microphone system it needs a condition that the sound source to be detected should be stationary state and in rest. However here we introduce a method that the spectral analysing and the directivity of synthesis can be separately carried out by using a linear array of many microphones, in which each output of the microphone is multiplied by appropriate weighting coefficient and all of those products are summed after passing through adequate filters. The resultant signal is then sampled with an adequate sampling frequency and taken average for processing.

  • PDF

An Adaptive Feedback Canceller for Fully Implantable Hearing Device Using Tympanic Membrane Installed Microphone (고막이식형 마이크로폰을 위한 이식형 인공중이 적응 피드백 제거기 구현)

  • Kim, Tae Yun;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.189-199
    • /
    • 2016
  • Many implantable hearing aids are being developed as alternatives to conventional hearing aids which has inconveniences for use and social stigma that make hearing-impaired people avoid to wear it. Particularly, the fully-implantable middle ear hearing devices (F-IMEHD) are being actively studied for mixed or sensorineural hearing impaired people. In development of F-IMEHD, the most difficult problem is improving the performance of implantable microphone. Recently, Cho et al. have studied the tympanic membrane installed microphone which has better sensitivity and is easier to operate on patient than the microphone implanted under the skin. But, it may cause howling problem due to the feedback signal via oval window and ossicle chain from the transducer on round window in the middle ear cavity, therefore, a feedback canceller is necessary. In this paper, we designed NLMS (normalized least mean square) adaptive feedback canceller for F-IMEHD with tympanic membrane installed microphone and a transducer implemented at round window, and computer simulation was performed to verify its operation. The designed adaptive feedback canceller has a delay filter, a 64 point FIR fixed filter and a 8-tap adaptive FIR filter. Computer simulation of the feedback path is modeled by using the data obtained through human cadaver experiment.

Development of Voice Signal Detection System using FPGA (FPGA를 이용한 음성 신호 감지 시스템 개발)

  • Kim, Jang-Won
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.141-146
    • /
    • 2015
  • In order to classify and analyze variously compounded sound and voice signal from FPGA microphone, there are numerous systems to detect abnormality signal, however, they have a lot of problems to implement the abnormality signal detection efficiently and effectively. Therefore, we proposed a method that implements classifying the signal effectively and outputting the detection efficiently based on the algorithm applied FIFO structure (First-in First-out) by using microphone sensor which able to input the sound signal, and statistical variance and coefficient of variation (CV). The result showed 96.3% detection when the experiment was performed more than 100 times with the proposed algorithm applied system.

Performance of Different Sensors for Monitoring of the Vibration Generated during Thermosonic Non-destructive Testing

  • Kang, Bu-Byoung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.111-117
    • /
    • 2011
  • Vibration monitoring is required for reliable thermosonic testing to decide whether sufficient vibration is achieved in each test for the detection of cracks. From a practical point of view, a cheaper and convenient monitoring method is better for the application to real tests. Therefore, the performance of different sensors for vibration monitoring was investigated and compared in this study to find a convenient and acceptable measurement method for thermosonics. Velocity measured by a laser vibrometer and strain provide an equivalent HI when measured at the same position. The microphone can provide a cheaper vibration monitoring device than the laser and the heating index calculated by a microphone signal shows similar characteristics to that calculated from velocity measured by the laser vibrometer. The microphone frequency response shows that it underestimates high frequency components but it is applicable to practical tests because it gives a conservative value of HI.

The microphone system of the cellular phone for privately telephonic communication (속삭임 통화를 위한 휴대 전화용 마이크로폰 시스템)

  • 최성준;문원규;이정현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1335-1340
    • /
    • 2001
  • The information technology brought us many kinds of conveniences to our life, but it also caused social problems such as privacy interference, unexpected personal information leaks, and nose generation by telephonic talks, etc. In this paper, the microphone system of the cellular phone is developed to prevent these problems caused by progress of information technology. The developed system was designed to detect only acoustic signals from a human being in the presence of various kinds of background noises. A windscreen was designed by use of micro-channels to eliminate the popping noise by the wind from the mouth of a speaker and four microphone array and signal processing techniques are applied to reduce background noise. The impact of the developed system was evaluated by experimental tests. The results show that the system can improve the required functions considerably.

  • PDF

A Novel Computer Human Interface to Remotely Pick up Moving Human's Voice Clearly by Integrating ]Real-time Face Tracking and Microphones Array

  • Hiroshi Mizoguchi;Takaomi Shigehara;Yoshiyasu Goto;Hidai, Ken-ichi;Taketoshi Mishima
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.75-80
    • /
    • 1998
  • This paper proposes a novel computer human interface, named Virtual Wireless Microphone (VWM), which utilizes computer vision and signal processing. It integrates real-time face tracking and sound signal processing. VWM is intended to be used as a speech signal input method for human computer interaction, especially for autonomous intelligent agent that interacts with humans like as digital secretary. Utilizing VWM, the agent can clearly listen human master's voice remotely as if a wireless microphone was put just in front of the master.

  • PDF

A Study on the Compensating System for the Acoustic Characteristics Caused by the Variation of Distance from Sound Source to Microphone (음원과 마이크로폰 사이의 거리변화에 의한 음향 특성 보정에 관한 연구)

  • Jeoung, Byung-Chul;Choe, Yoon-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.197-204
    • /
    • 2012
  • In this thesis, studied the method to minimize the changes in frequency response and level due to the variation of the distance from the source to the microphone. selecting three microphones (omni directional, cardioid, super cardioid) which are being used generally, frequency responses were measured in accordance with the distance changes. Gotten the difference from the reference as the result of measurement, changed responses for each frequency range were compensated in comparison of the original human vocal source. In low frequency range, the low frequency boost caused by the proximity effect and decrease in accordance with the distance were compensated. The variation in mid-frequency range is comparatively small, however since the mid-range is the most important part of the human vocal signal, were compensated the mid-frequency range in comparison of the reference. The human vocal signal variation in high frequency range is extremely small and the high frequency is compensated close to the original source without difficulty. Understanding the microphone characteristics and compensations, this study showed that the response can be maintain among the change of the distance from the source to the microphone.

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

Optimum Design of the Microphone Sensor Array for 3D TDOA Positioning System (3차원 TDOA 위치인식 시스템의 마이크 센서 배열 최적 설계)

  • Oh, Jongtaek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • A study on the indoor positioning system has been active recently for the location based service indoors. In the 3 dimensional positioning system based on the acoustic signal and TDOA technology, the error characteristics of the estimated source position would be changed depending on the number of microphones and the pattern of the microphone array. In this paper, the estimated position error according to the measured distance error between the microphones and the signal source is analyzed, and the optimum microphone array is decided considering the estimated position error patterns and the total amount of the estimated position error.

The Effect of Reference Mic. Array Shape on MUSIC and Beamforming Methods in Acoustical Holography (음향 홀로그래피에서 기준 마이크로폰 어레이가 빔형성 방법과 다중 신호 분리 방법에 미치는 영향)

  • 이원혁;이명준;강연준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1003-1008
    • /
    • 2001
  • In beamforming method, source positions are predicted by MUSIC (Multiple Signal Classification) power method and composite sound fields can then be decomposed into each partial field by beamforming, detenninistically without restriction of the distance between reference microphones and sources. However, reference microphone array shape is important in both MUSIC and beamforming method. Thus the present paper describes the effect of the reference microphone array shape.

  • PDF