• Title/Summary/Keyword: Microfludics

Search Result 5, Processing Time 0.019 seconds

Preparation and Characterization of Lipid Nanoparticles Containing Fat-Soluble Vitamin C Derivatives and Gallic Acid (지용성 비타민 C 유도체 및 갈릭산을 함유한 지질나노입자 제조 및 특성)

  • Ji Soo Ryu;Ja In Kim;Jae Yong Seo;Young-Ah Park;Yu-Jin Kang;Ji Soo Han;Jin Woong Kim
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.50 no.2
    • /
    • pp.103-110
    • /
    • 2024
  • Lipid nanoparticles (LNPs) are a stable and an effective system that protects cell-impermeable biologically active compounds such as nucleic acids, proteins, and peptides against degradation caused by subtle environmental changes. This study focuses on developing LNPs encapsulating gallic acid (GA), an antioxidant, to effectively prolong the half-life of tetrahexyldecyl ascorbate (THDC), a oil-soluble vitamin C derivative. These LNPs were synthesized in small, uniform sizes at room temperature and pressure conditions using a microfluidics chip. Compared to liposomes manufactured under high pressure and high temperature conditions through conventional microfluidizers, LNPs manufactured through microfluidics chips had excellent dispersion and temperature stability, and improved skin absorption as well as improved oxidative stability of fat-soluble vitamin C derivatives. Future studies will focus on ex vivo and in vivo evaluations to study skin improvement to further validate these results.

Fabrication of 3D Metallic Molds for Multi-replication of Microstructures (극미세 3 차원 형상복제를 위한 금속몰드 제작에 관한 연구)

  • Bae, Kong-Myung;Ko, Jong-Soo;Park, Sang-Hu;Lim, Tae-Woo;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.8
    • /
    • pp.119-125
    • /
    • 2009
  • Fabrication of a three-dimensional (3D) metallic mold for multi-production of a microstructure was studied to settle the problem of long processing time in 3D microfabrication. To date, complicated 3D microstructures including 3D photonic crystals, 3D microlens array, 3D filter for microfludics, and something else were created successfully using the two-photon polymerization (TPP) which was considered as paving the way to fabricate a real 3D shape in nano/microscale. However, for those fabrications, much processing time and efforts were inevitably required. To solve this issue, a simple and effective way was proposed in this paper; 3D master patterns were prepared using TPP, and then counter-shaped Ni molds were fabricated by electroforming process. By using these molds, 3D microstructures can be reproduced with short-processing time and low-effort comparing to the conventional approach, TPP We report some parameters to fabricate a metallic mold precisely.

Analysis of Flow in a Microchannel Branch by Using Micro-PIV Method (마이크로 PIV를 이용한 마이크로 분지관에서의 유동해석)

  • Yoon, Sang-Youl;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1015-1021
    • /
    • 2004
  • Micro-resolution Particle Image Velocimetry(Micro-PIV) was used to measure the flow in a micro-branch(Micro-Bypass). In this paper, effects of particle lump at the tip of a Micro-branch and difficulties of Micro-PIV measurements for microfluidics with branch passage were described. Micro-bypass was composed of a straight channel(200(100)${\mu}$m width ${\times}$ 80${\mu}$m height) and two branches which has 100(50)${\mu}$m width ${\times}$ 80${\mu}$m height. One of branches was straight and the other was curved. Experiments were performed at three regions along streamwise direction(entrance, middle and exit of branch) and five planes along vertical direction (0, ${\pm}$10, ${\pm}$20 ${\mu}$m) for the range of Re=0.24, 1.2, 2.4. Numerical simulation was done to compare with the measurements and understand the effects of particle lump at the tip of branch. And another fluid(3% poly vinyl Alcohol aqueous solution) were adapted for this study, so there were no particle sticking. In this case, we could get velocity difference between straight and curved branches.

Effect of Intersection Angle of the Flow-focusing Type Droplet Generation Device Channel on Droplet Diameter by using Numerical Simulation Modeling (수치해석 모델링을 이용한 교차 흐름 미세유체 액적 생성 디바이스 채널 교차각이 액적 직경에 미치는 영향)

  • Kim, Shang-Jin;Kang, Hyung-Sub;Yang, Yeong-Seok;Kim, Gi-Beum
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.61-68
    • /
    • 2015
  • In this paper, we studied the effects of intersection angles of the flow-foucusing type droplet generation device inlet channel on droplet diameter using numerical simulation modeling. We modeled different intersection angles with a fixed continuous channel width, dispersed channels width, orifices width, and expansion channels width. Numerical simulations were performed using COMSOL Multiphysics$^{(R)}$ to solve the incompressible Navier-Stokes equations for a two-phase flow in various flow-focusing geometries. Modeling results showed that an increase of the intersection angle causes an increase in the modification of the dispersed flow rate ($v^{\prime}{_d}$), and the increase of the modification of the continuous flow rate ($v^{\prime}{_c}$) obstructs the dispersed phase fluid flow, thereby reducing the droplet diameter. However, the droplet diameter did not decrease, even when the intersection angle increased. The droplet diameter decreased when the intersection angle was less than $90^{\circ}$, increased at an intersection angle of $90^{\circ}$, and decreased when the intersection angle was more than $90^{\circ}$. Furthermore, when the intermediate energy deceased, there was a decrease in the droplet diameter when the intersection angle increased. Therefore, variations in the droplet diameter can be used to change the intersection angle and fluid flow rate.

The Effects of pH on Microfluidics Flow Characteristics of Heavy Metals (중금속 오염물의 미세유체 흐름특성에 미치는 pH 영향에 관한 연구)

  • Han, Jung-Geun;Kim, Dong-Chan;Hong, Kikwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 2015
  • This paper describes a flow experiment and characteristics of heavy metals based on microfluidics, in order to improve the prefabricated vertical drain system that is possible pollutants removal and soil improvement in soft ground polluted with various pollutants, simultaneously. The result showed that the surface with hydrophobic condition affected large effect on flow velocity pollutants, and pH condition was also influence factor for change of flow velocity. Especially, the flow velocity of lead has risen slightly, when pH was close to basicity in complex heavy metal. This means that lead pollutant can reduce a hydrophobic characteristic in comparison with a copper pollutant.