• Title/Summary/Keyword: Microclimate control

검색결과 75건 처리시간 0.03초

쾌적한 군복 설계를 위한 의복기후 분포 (Distribution of clothing microclimate for making comfortable military uniform)

  • 김양원
    • 안보군사학연구
    • /
    • 통권1호
    • /
    • pp.231-247
    • /
    • 2003
  • To get the basic data for making comfortable military uniforms and to examine the distribution of clothing microclimate, seasonal fluctuations of skin temperature, subjective sensation, and clothing microclimate were measured from 10 males. The subject were questioned on thermal comfort in experiment. Clothing microclimate temperature at breast, skin temperature at four sites (breast, upper arm, thigh, leg), deep body temperature at eardrum( tympanic temperature), and subjective sensation were measured for an hour in the controlled climatic chamber. The subjects felt comfortable when skin temperature were recorded $34.43^{\circ}C$ at breast, $33.53^{\circ}C$ at upper arm, $32.9^{\circ}C$ at thigh, and 32.50 at leg. Then mean skin temperature was $33.55\pm$$0.63^{\circ}C$. Clothing microclimate temperature ranged from 31.2 to $33.8^{\circ}C$, and clothing microclimate humidity ranged from 49.80~52.41%. In the comparison of these results with the microclimate of military uniforms, it needs more insulation in clothing for military uniforms. It also says that military uniforms should be made of the textiles which can control humidity.

  • PDF

THE SIMPLE & EASY ENVIROMENTAL CONTROL FOR THE MEMBRANE GREENSHED OF VEGETABLES IN CHINA

  • Weicheng, Xia
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.495-504
    • /
    • 1993
  • In China, the membrane greensheds are chiefly for yielding vegetables, using simple & easy methods to control the microclimate. The yield of the vegetable is raised & the lack of variety of vegetable in the slack season is overcome. This paper presents the general planning , the environmental control and the reformed designs of such greenshed in China.

  • PDF

자연에너지와 건축조경계획

  • 조균형
    • 태양에너지
    • /
    • 제13권2_3호
    • /
    • pp.22-29
    • /
    • 1993
  • 건물의 실내 온열환경과 에너지 소비량은 건물 주변에 형성되는 미기후에 의해 일차적인 영향을 받게 된다. 따라서 미기후의 조건을 완화 혹은 순화시켜 가능한 건물 실내조건과의 차이를 줄이는 것이 건물의 에너지절약효과를 향상시키는 첫단계이며 자연에너지를 이용한 쾌적한 거주 환경조성에 기여하는 방법이 된다. 이와같은 관점에서, 본고에서는 대지내 경관을 아름답게 해주면서 또한 미기후 형성에 그 영향도가 매우 높은 조경요소들에 대해 그 종류 및 기후조절기능을 분석하고 조경계획의 주안점을 건물 열부하에 영향을 주는 항목별로 나누어 조사, 정리하여 바람직한 조경 계획을 수립하는데 기초자료를 제시하였다.

  • PDF

An Intelligent Wireless Sensor and Actuator Network System for Greenhouse Microenvironment Control and Assessment

  • Pahuja, Roop;Verma, Harish Kumar;Uddin, Moin
    • Journal of Biosystems Engineering
    • /
    • 제42권1호
    • /
    • pp.23-43
    • /
    • 2017
  • Purpose: As application-specific wireless sensor networks are gaining popularity, this paper discusses the development and field performance of the GHAN, a greenhouse area network system to monitor, control, and access greenhouse microenvironments. GHAN, which is an upgraded system, has many new functions. It is an intelligent wireless sensor and actuator network (WSAN) system for next-generation greenhouses, which enhances the state of the art of greenhouse automation systems and helps growers by providing them valuable information not available otherwise. Apart from providing online spatial and temporal monitoring of the greenhouse microclimate, GHAN has a modified vapor pressure deficit (VPD) fuzzy controller with an adaptive-selective mechanism that provides better control of the greenhouse crop VPD with energy optimization. Using the latest soil-matrix potential sensors, the GHAN system also ascertains when, where, and how much to irrigate and spatially manages the irrigation schedule within the greenhouse grids. Further, given the need to understand the microclimate control dynamics of a greenhouse during the crop season or a specific time, a statistical assessment tool to estimate the degree of optimality and spatial variability is proposed and implemented. Methods: Apart from the development work, the system was field-tested in a commercial greenhouse situated in the region of Punjab, India, under different outside weather conditions for a long period of time. Conclusions: Day results of the greenhouse microclimate control dynamics were recorded and analyzed, and they proved the successful operation of the system in keeping the greenhouse climate optimal and uniform most of the time, with high control performance.

Girdle 착용이 인체생리반응과 의복기후에 미치는 영향 (A Study on the Physiological Responses and the Microclimate in Girdle)

  • 김현식;최정화
    • 한국의류학회지
    • /
    • 제11권2호
    • /
    • pp.57-67
    • /
    • 1987
  • The purpose of this study was to confirm the effects of girdle on the physiological responses and the microclimate in summer. The measuring points were rectal temperature, skin temperature, pulse rate and sweat volume as physiological responses and the inside clothing temperature, relative humidity as microclimate when the subjects wore girdle (girdle A; polyurethan+nylon, girdle B; polyurethan+cotton) for the period of rest and exercise in climate chamber. The enviromental conditions were at $25^{\circ}C$ ($65{\pm}5\%$ RH) and $30^{\circ}C$ ($75{\pm}5\%$ RR). The results were as followings. 1. Mean skin temperature increased in girdle during the exercise at $30^{\circ}C$. 2. The pulse rate decreased in girdle during the rest at $25^{\circ}C$. In the case of girdle A, it was remarkably decreased. Rectal temperature increased in girdle A and B during the exercise at $25^{\circ}C$. But the kinds of girdle didn't affect the pulse rate and rectal temperature. 3. The total sweat volume in girdle was larger than in control. 4. The difference between skin temperature and inside clothing temperature of abdomen had a tendency to increase at all experiment condition. 5. The relative humidity of inside ($RH_1$) and outside ($RH_2$) of girdle increased in girdle during the rest at $25^{\circ}C$ and $30^{\circ}C$. And the relative humidity of wearing girdle B was hig-her than girdle A during the rest at $25^{\circ}C$ and $30^{\circ}C$. The $RH_1$ after stepping at $30^{\circ}C$ was the highest in girdle A and the lowest in control. From this point of view, we concluded that physiological responses and the microclimate were affected by wearing girdle. And mean skin temperature and relative humidity of inside clothing were affected by the materials of girdle.

  • PDF

데이터 기반 모델에 의한 강제환기식 육계사 내 기온 변화 예측 (Data-Based Model Approach to Predict Internal Air Temperature in a Mechanically-Ventilated Broiler House)

  • 최락영;채영현;이세연;박진선;홍세운
    • 한국농공학회논문집
    • /
    • 제64권5호
    • /
    • pp.27-39
    • /
    • 2022
  • The smart farm is recognized as a solution for future farmers having positive effects on the sustainability of the poultry industry. Intelligent microclimate control can be a key technology for broiler production which is extremely vulnerable to abnormal indoor air temperatures. Furthermore, better control of indoor microclimate can be achieved by accurate prediction of indoor air temperature. This study developed predictive models for internal air temperature in a mechanically-ventilated broiler house based on the data measured during three rearing periods, which were different in seasonal climate and ventilation operation. Three machine learning models and a mechanistic model based on thermal energy balance were used for the prediction. The results indicated that the all models gave good predictions for 1-minute future air temperature showing the coefficient of determination greater than 0.99 and the root-mean-square-error smaller than 0.306℃. However, for 1-hour future air temperature, only the mechanistic model showed good accuracy with the coefficient of determination of 0.934 and the root-mean-square-error of 0.841℃. Since the mechanistic model was based on the mathematical descriptions of the heat transfer processes that occurred in the broiler house, it showed better prediction performances compared to the black-box machine learning models. Therefore, it was proven to be useful for intelligent microclimate control which would be developed in future studies.

광합성효율 모델을 이용한 밀폐형 식물 생산시스템의 재배환경 최적화 (Optimization of Growth Environment in the Enclosed Plant Production System Using Photosynthesis Efficiency Model)

  • 김기성;김문기;남상운
    • 생물환경조절학회지
    • /
    • 제13권4호
    • /
    • pp.209-216
    • /
    • 2004
  • 본 연구에서는 폐쇄형 식물 생산시스템 내에서 생체정보에 의한 최적 환경제어와 식물의 환경스트레스 판단을 위하여 엽록소형광 분석법으로 광합성효율 모델을 만들었으며, 광합성효율 모델에 유전알고리즘을 적용하여 재배환경 최적화 프로그램의 응용성을 평가하였다. 6가지 미기상 요인 중 5가지는 고정하고 1가지씩만 변화시켜 가며 측정한 Fv'/Fm'이 최대가 되는 환경조건은 기온 $21^{\circ}C,\;CO_2$농도 $1,200\~1,400ppm$, 상대습도 $68\%$, 기류속도 $1.4m{\cdot}s^{-1}$, 배양액온도 $20^{\circ}C$이었으며 PPF가 $140{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ 보다 증가할수록 광합성 효율은 감소하였다. 광합성효율모델의 오차는 평균 $2.5\%$였다. 재배환경 최적화 프로그램으로부터 계산된 밀폐형식물 생산시스템내에서 상추의 최적재배환경조건은 기온 $22^{\circ}C$, 배양액온도 $19^{\circ}C,\;CO_2$농도 1,400ppm, 기류속도 $1.0m{\cdot}s^{-1}$, PPF $430{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 상대습도 $65\%$이다. 이상의 연구 결과로부터 광합성 효율 모델을 이용하여 식물 생산시설의 환경모니터링 시스템과 식물 생체정보에 의한 최적제어시스템의 개발이 가능함을 확인하였다.

Intelligent Microclimate Control System Based on IoT

  • Altayeva, Aigerim Bakatkaliyevna;Omarov, Batyrkhan Sultanovich;Cho, Young Im
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제16권4호
    • /
    • pp.254-261
    • /
    • 2016
  • The present research paper is devoted to solving an urgent problem, i.e., the energy saving and energy efficiency of buildings. A rapid settlement method and experimental control of the energy conservation based on the specific characteristics of the thermal energy consumption for the heating and ventilation of the buildings, and as well as the rapid development of wireless sensor networks, can be used in a variety of monitoring parameters in our daily lives. Today's world has become quite advanced with smart appliances and devices such as laptops, tablets, TVs, and smartphones with various functions, and their use has increased significantly in our day-to-day lives. In this case, the most important role is played by a wireless sensor network with its development and use in heterogeneous areas and in several different contexts. The fields of home automation, process management, and health management systems make extensive use of wireless sensor networks. In this paper, we explore the main factors of the microclimate in an indoor environment. We control the temperature humidity, and other factors remotely using sensors and Internet-of-Things technologies.

냉각조끼착용에 따른 인체의 온열생리학적 특성 (Thermophysiological Response of Human Body in Wearing Codling Vest)

  • 권오경;김태규
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2000년도 추계학술대회 논문집
    • /
    • pp.148-154
    • /
    • 2000
  • To do this study, we produced cooling vest newly. Rectal temperature was ascended approximately from 37.2$^{\circ}C$ to 38.05$^{\circ}C$ in lab, but wearing cooling vest, the temperature was descended 0.2 while wearing developed product compare with existing product. Mean skin temperature which was showed distribution from 32.8∼36.5$^{\circ}C$, it was descended 1.0∼1.1$^{\circ}C$, while wearing cooling vest and comparing with existing product, wearing developed product was lower 0.5$^{\circ}C$, While wearing developed product, it was found that they had lower tendency than exiting product. Specifically in case of temperature within clothing(chest) 0.2∼2.0$^{\circ}C$ in case of humidity within clothing 2∼8% RH. Facts from above we confirmed that clothing microclimate had been improved and space was happened between body and garment in order to control. In subjective sensation, existing product made negative response during experiment period from participants, but developed product was nearing to comfortable area.

  • PDF

훼손된 생태계의 복원을 통한 생태계 서비스의 회복: 채탄쓰레기 매립지 복원지의 사례 (Recovery of Ecosystem Service Functions through Ecological Restoration Practice: A Case Study of Coal Mine Spoils, Samcheok, Central Eastern Korea)

  • 오우석;이창석
    • 환경생물
    • /
    • 제32권2호
    • /
    • pp.102-111
    • /
    • 2014
  • Ecological restoration is regarded as a major strategy for preventing biodiversity loss and thereby enhancing ecosystem service. This study was performed to evaluate ecosystem service value that the restored ecosystem provides. Ecosystem service was evaluated for provisioning and regulating services. The former service was evaluated by comparing similarities in a viewpoint of floristic composition to the reference site between the restored and the unrestored sites. Species composition of the restored site was found to be more similar to the reference site than that of the unrestored site and thereby restoration practice contributed for enhancing the provisioning service. Regulating service was evaluated based on microclimate control, soil amelioration, and improvement of water holding capacity. The value of ecosystem services in terms of microclimate control, soil amelioration, and improvement of water holding capacity was higher in the restored site than in the unrestored site. In consequence, ecological restoration of coal mine spoils contributed for enhancing the ecosystem service value of the corresponding site and thereby is rewarding the cost invested for restoration.