• 제목/요약/키워드: Microchip

검색결과 136건 처리시간 0.03초

OLED광원이 집적화된 마이크로 플루이딕칩의 제작 및 특성 평가 (Fabrication and characteristic evaluation of microfluidics chip integrated OLED for the light sources)

  • 김영환;한진우;김종연;김병용;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.377-377
    • /
    • 2007
  • A simplified integration process including packaging is presented, which enables the realization of the portable fluorescence detection system. A fluorescence detection microchip system consisting of an integrated PIN photodiode, an organic light emitting diode (OLED) as the light source, an interference filter, and a microchannel was developed. The on-chip fluorescence detector fabricated by poly(dimethylsiloxane) (PDMS)-based packaging had thin-film structure. A silicon-based integrated PIN photo diode combined with an optical filter removed the background noise, which was produced by an excitation source, on the same substrate. The active area of the finger-type PIN photo diode was extended to obtain a higher detection sensitivity of fluorescence. The sensitivity and the limit of detection (LOD S/N = 3) of the system were $0.198\;nA/{\mu}M$ and $10\;{\mu}M$, respectively.

  • PDF

펩타이드 질량 분석을 위한 전기 이온화 분사기의 제작 및 성능 평가 (Mass spectrometry analysis system with integrated micro electrospray ionization emitter for peptide detection)

  • 김민수;주황수;김병기;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1534-1535
    • /
    • 2007
  • This paper describes a novel microfluidic device with a microfabricated electrospray source for a sheathless electrospray ionization interface to a mass spectrometer. This electrospray ionization-mass spectrometry (ESI-MS) device consists of a triangular-shaped metal emitter, allowing the generation of an efficient electrospray for peptide detection, and microfluidic channels monolithically in a glass microchip. The performance of the proposed interface was evaluated by opimizing its experimental condition and spraying standard peptides. The spraying has high signal strength and stability, with a relative standard deviation of 2.9% and singly-charged and doubly-charged peaks of the peptides were successfully detected. The metal emitter source showed a good performance to be comparable to commercially available emitters in signal strength and stability.

  • PDF

Study on Bead-based Microbiochip and Analytical System for Protein Detection

  • Kim, Min-Soo;Chung, Woo-Jae;Cho, Su-Hyung;Park, Sung-Soo;Kim, Byung-Gee;Lee, Young-Sik;Kim, Yong-Kweon
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.60-63
    • /
    • 2002
  • This paper presents bead-based microbiocihps to detect and separate target proteins. Micro beads coated with capture proteins were introduced into a microchamber, and target proteins flowing across the chamber were bound and concentrated. The chip was connected with an external fluid system. Bead surfaces were double-coated with photo-cleavable linkers and capture proteins. The proteins bound on the beads were photo-separated under UV irradiation, and excited to be measured in fluorescence. $38{\sim}50{\mu}m$ sized polystyrene beads were used. SOGs(silicon-on-glass) were used to fabricate the microchip having glasses bonded on both sides. 100 ${\mu}m$ thick silicon channel was formed through silicon deep RIE process. The upper glass cover had holed through to have inlets and outlets fabricated by powder-blastings. In this study, biotin and streptavidin were used as capture proteins and detection proteins, respectively. The protein mixtures of streptavidin, HSA(human serum albumin) and ovalbumin were applied for selective detection test.

  • PDF

지연시간을 개선하기 위한 마이크로 컨트롤러의 효율적인 프로그래밍 방법 (Efficient Programming Method in Microcontrollers for Improving Latency)

  • 이경남;김영민
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.1068-1076
    • /
    • 2019
  • 오늘날 우리가 사용하고 있는 대부분의 전자제품에는 마이크로 컨트롤러가 내장되어 있으며, 이를 내장한 미니컴퓨터를 임베디드 시스템이라고 한다. 이러한 소규모 환경에서는 마이크로 컨트롤러에 응답성이 매우 중요한데 본 논문에서는 마이크로 컨트롤러에 기본적인 입출력 제어, 타이머/카운터 인터럽트 동작원리 및 이해에 대한 내용과 더불어 마이크로 컨트롤러 내의 플래시메모리에 각 프로그램 실행 루틴인 메인 루틴 및 인터럽트 서비스루틴에 대한 특징 및 프로그램 실행 순서를 컨트롤하여 처리율과 레이턴시를 개선하는 프로그램 로직을 제안하고 있다. 본 논문에서의 하드웨어 시뮬레이션은 아트멜사와 마이크로칩사에서 출시한 ATmega128과 PIC16F877A 마이크로 컨트롤러를 이용하여 검증이 실시되었다.

다구찌법을 이용한 IR 레이저 Flip-chip 접합공정 최적화 연구 (A Study on the Optimization of IR Laser Flip-chip Bonding Process Using Taguchi Methods)

  • 송춘삼;지현식;김주한;김종형;안효석
    • Journal of Welding and Joining
    • /
    • 제26권3호
    • /
    • pp.30-36
    • /
    • 2008
  • A flip-chip bonding system using IR laser with a wavelength of 1064 nm was developed and associated process parameters were analyzed using Taguchi methods. An infrared laser beam is designed to transmit through a silicon chip and used for transferring laser energy directly to micro-bumps. This process has several advantages: minimized heat affect zone, fast bonding and good reliability in the microchip bonding interface. Approximately 50 % of the irradiated energy can be directly used for bonding the solder bumps with a few seconds of bonding time. A flip-chip with 120 solder bumps was used for this experiment and the composition of the solder bump was Sn3.0Ag0.5Cu. The main processing parameters for IR laser flip-chip bonding were laser power, scanning speed, a spot size and UBM thickness. Taguchi methods were applied for optimizing these four main processing parameters. The optimized bump shape and its shear force were modeled and the experimental results were compared with them. The analysis results indicate that the bump shape and its shear force are dominantly influenced by laser power and scanning speed over a laser spot size. In addition, various effects of processing parameters for IR laser flip-chip bonding are presented and discussed.

세탁기 진동소음의 저감을 위한 MR 댐퍼 컨트롤 모듈 개발 (The development of MR damper control modules for a vibration and noise decrease in Washing machine system)

  • 손경민;김민;김관형;변기식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.185-187
    • /
    • 2012
  • 본 논문에서 응용하고자 하는 MR 유체 댐퍼는 상자성(paramagnetic) 입자를 MR 유체 내부에 분산시켜 전류에 따라 발생하는 전자석 원리를 이용하여 MR 댐퍼 내부의 유체의 항복 전달 응력의 변화 실키 수 있는 특징이 있다. 즉, 전류의 세기에 따라 MR 유체 댐퍼 내부의 마찰계수가 달라지는 현상을 이용하는 것이다. 이러한 MR 유체 댐퍼 제어에 사용하고자 하는 MCU는 마이크로칩 사의 dsPIC 칩을 이용하여 성능을 개선하고자 하며 전류제어에는 PWM을 이용하며, 외부 모니터링을 위하여 UART 통신을 이용하여 전체 시스템을 모니터링 하도록 설계하였다. 본 연구에서는 MR 유체 댐퍼와 dsPIC 칩을 사용하여 세탁기의 탈수 과정 시 발생 되는 진동 및 소음을 저감 시키도록 세탁기용 진동 및 소음방지 시스템을 제안하고자 한다.

  • PDF

Digital Signal Processor를 이용한 실시간 전력 요소와 왜율 측정 시스템 설계 (System Design for Real-Time Measuring of Power Quality and Harmonics Distortion using Digital Signal Processor)

  • 김근준;강봉순
    • 한국정보통신학회논문지
    • /
    • 제20권7호
    • /
    • pp.1283-1289
    • /
    • 2016
  • 전력은 현대 사회를 구성하는데 있어 필수적인 자원이다. 최근, 전력에 대한 수요가 급격하게 증가하였으며 전력 수요 증가는 전력 품질의 저하를 야기하였다. 현대 사회에서 전력 품질은 일반 가정과 산업 전반에 걸쳐 큰 문제를 일으킬 수 있는 중요한 요소가 되었다. 전력 품질 문제를 예방하기 위해서는 전력 품질에 대한 계측과 초기 대응이 중요하다. 본 논문에서는 실시간으로 전력 품질을 계측하고 고조파를 분석하여 모니터링 할 수 있는 시스템 제안한다. 마이크로칩의 dsPIC33FJ256GP710A칩을 이용한 DM240001보드를 이용하여 최대 3상 3선에 해당하는 배선 방식의 전력 품질을 계측하는 시스템을 설계하였고, 계측 알고리즘의 최적화로 전력 품질의 순간적인 변화를 측정할 수 있도록 하였다. 또한, 최대 31차에 해당하는 고조파들에 대하여 전압과 전류의 왜율과 수요 전류 왜율에 대해서도 측정 가능하도록 설계하였다.

상피세포 시료 전처리용 마이크로바이오칩에 관한 연구 (Study on Microbiochip for Buccal Cell Lysis and DNA Purification)

  • 하승모;조웅;안유민;황승용
    • 대한기계학회논문집A
    • /
    • 제34권12호
    • /
    • pp.1785-1791
    • /
    • 2010
  • 중합효소 연쇄반응(PCR)을 수행하려면 세포 용해(cell lysis)와 DNA추출(DNA purification)과정이 포함된 시료 전처리 과정을 거쳐야 한다. 종래의 시료 전처리 과정은 계면활성제와 같은 세포용해 버퍼를 이용하거나 열 또는 전기적 방법으로 세포막 파열을 유도하여 세포벽을 깬 후에 잔여물 처리과정을 거쳐 DNA를 추출하게 된다. 본 연구에서는 마이크로 비드와 PDMS 기둥을 이용한 필터가 있는 시료 전처리용 바이오칩을 설계 및 제작하였다. 또한 제작된 바이오칩을 사용하여 $80^{\circ}C$에서 2분간 세포용해를 수행하고 DNA를 추출하였다. 칩에서 전처리과정을 거친 시료내의 DNA농도와 순도를 측정하고 DNA PCR과 겔 전기영동을 통해 시료 전처리용 바이오칩의 성능을 평가하였다.

Polydimethylsiloxane 기반 미세유체시스템의 음향열적 가열 및 응용 (Acoustothermal Heating of Polydimethylsiloxane Microfluidic Systems and its Applications)

  • 성형진;하병항;박진수;굴람 데스트기르;정진호
    • 한국가시화정보학회지
    • /
    • 제14권1호
    • /
    • pp.57-61
    • /
    • 2016
  • We report a finding of fast(exceeding 2,000 K/s) heating of polydimethylsiloxane(PDMS), one of the most commonly-used microchannel materials, under cyclic loadings at high(~MHz) frequencies. A microheater was created based on the finding. The heating mechanism utilized vibration damping of sound waves, which were generated and precisely manipulated using a conventional surface acoustic wave(SAW) microfluidic system, in PDMS. The penetration depths were measured to range from $210{\mu}m$ to $1290{\mu}m$, enough to cover most microchannel heights in microfluidic systems. The energy conversion efficiency was SAW frequency-dependent and measured to be the highest at around 30 MHz. Independent actuation of each interdigital transducer(IDT) enabled independent manipulation of SAWs, permitting spatiotemporal control of temperature on the microchip. All the advantages of this microheater facilitated a two-step continuous flow polymerase chain reaction(CFPCR) to achieve the billion-fold amplification of a 134 bp DNA amplicon in less than 3 min. In addition, a technique was developed for establishing dynamic free-form temperature gradients(TGs) in PDMS as well as in gases in contact with the PDMS.

도서 관리를 위한 RFID 태그 데이터 포맷 설계 및 시스템 구현 (Design of RFID Tag Data Format for Books Information Management and Implementation of System)

  • 정필성;정원수;오영환
    • 전자공학회논문지CI
    • /
    • 제44권3호
    • /
    • pp.1-7
    • /
    • 2007
  • RFID(Radio Frequency IDentification)는 자동인식 기술의 한 종류로서 마이크로칩을 내장한 태그, 카드, 라벨 등에 저장된 데이터를 무선 주파수를 사용하여 사물이나 사람을 인식하는 기술이다. 기존에 널리 이용되던 바코드(Bar-code)를 대체하여 RFID를 사용함으로써 시스템의 자동화와 효율적인 자료 관리가 가능하다. 본 논문에서는 도서정보관리에 필요한 정보를 바탕으로 도서정보관리용 RFID 태그 데이터 포맷을 설계하고 이를 기반으로 하여 시스템을 구현하였다. RFID를 이용한 도서관리 시스템은 장서 점검기, 자가 대출기, 자가 반납기, 사서용 관리 시스템으로 나누어지며 RFID 리더에 인식된 태그의 정보를 RS-232 인터페이스를 통하여 호스트 컴퓨터에 전송되며 호스트 컴퓨터에서는 미들웨어를 구성하여 정보를 처리.운영하게 된다. 본 본문에서 구현한 시스템은 도서정보관리를 위한 사서용 관리 시스템에 맞추어 구현하였다.