• 제목/요약/키워드: Microbial Fuel Cell

검색결과 131건 처리시간 0.019초

생활폐수 내 혼합균주를 이용한 미생물 연료전지의 구동 특성에 관한 연구 (A Study on the Driving Characteristics of Microbial Fuel Cell Using Mixed Strains in Domestic Wastewater)

  • 김상규;유동진
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.506-513
    • /
    • 2021
  • The use of fossil fuels is a major contributor to the increase atmospheric greenhouse gas emissions. As such problems arise, interest in new and renewable energy devices, particularly fuel cells, is greatly increasing. In this study, various characteristics of mixed strains were observed in wastewater collected by the Jeonju Environment Office to investigate the effects of microorganisms on voltage generation and voltage generation of substrates, electrode materials, electrons, electron transport media, and ash microbial fuel cells. As a result of separately measuring the voltage generated during inoculation, the inoculation voltage of Escherichia coli K12 (E. coli K12) was 0.45 V, and the maximum inoculation voltage of the mixed strain was 1.2 V. Thereafter, voltage values were collected using a digital multimeter and the amount of voltage generated over time was measured. In the case of E. coli K12, the maximum voltage reached 0.45 V, and the cell voltage was maintained above 0.23 V for 140 hours. In contrast, for the mixed strain, the maximum voltage reached 1.2 V and the voltage was slowly decreased to 0.97 V. In addition, the degree of microbial adsorption to the electrod surface after the inoculation test was confirmed using a scanning electron microscope. Therefore, these results showed the possibility of purifying pollutants at the same time as power generation through the production of hydrogen ions using microorganisms and wastewater.

미생물 연료 전지와 전력 조절 시스템을 이용한 생체 유기 물질로부터의 전력 생산 (Energy Harvesting from Bio-Organic Substance Using Microbial Fuel Cell and Power Conditioning System)

  • 여정진;양윤석
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권5호
    • /
    • pp.242-247
    • /
    • 2017
  • This study presents a bio-chemical energy harvesting system which can generate electric power from bioorganic substance contained in vermicompost. It produced electricity by inoculating microbial fuel cell(MFC) with earthworm-composted food waste. The generated electricity was converted into usable voltage level for mobile electronics through power conditioning circuits. The implemented prototype showed $200{\mu}W$ of maximum output electric power, which successfully supplied a beacon device which continuously transmitted data to nearby smartphone without a battery. The proposed system can help develop portable or bio-mimetic energy supply for sustainable use with further improvement.

안정적 유출수질의 연속 하수처리를 위한 혐기성 멤브레인 필터와 통합된 미생물연료전지의 성능 평가 (Performance of Microbial Fuel Cell Integrated with Anaerobic Membrane Filter for Continuous Sewage Treatment with Stable Effluent Quality)

  • 이윤희;어성욱
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.808-812
    • /
    • 2013
  • A new type of microbial fuel cell (MFC) with anaerobic membrane filter was designed to produce bioelectricity and to treat domestic sewage at relatively high organic loading rate (OLR) of $6.25kgCOD/m^3/day$ and short hydraulic retention time (HRT) of 1.9 h. A following aeration system was applied to ensure effluent water quality in continuous operation. Glucose was supplemented to increase the influent concentration of domestic sewage. Influent substrate of 95% was removed via the MFC and following aeration system and the corresponding maximum power density was $25.6mW/m^3$. External resistor of $200{\Omega}$ and air-cathode system contributed better MFC performance comparing to $2000{\Omega}$ and dissolved oxygen as a catholyte.

Continuous removal of heavy metals by coupling a microbial fuel cell and a microbial electrolytic cell

  • Xie, Guo R.;Choi, Chan S.;Lim, Bong S.;Chu, Shao X.
    • Membrane and Water Treatment
    • /
    • 제11권4호
    • /
    • pp.283-294
    • /
    • 2020
  • This work aims at studying the feasibility of continuous removal of mixed heavy metal ions from simulated zinc plating wastewaters by coupling a microbial fuel cell and a microbial electrolysis cell in batch and continuous modes. The discharging voltage of MFC increased initially from 0.4621 ± 0.0005 V to 0.4864 ± 0.0006 V as the initial concentration of Cr6+ increased from 10 ppm to 60 ppm. Almost complete removal of Cr6+ and low removal of Cu2+ occurred in MFC of the MFC-MEC-coupled system after 8 hours under the batch mode; removal efficiencies (REs) of Cr6+ and Cu2+ were 99.76% and 30.49%. After the same reaction time, REs of nickel and zinc ions were 55.15% and 76.21% in its MEC. Cu2+, Ni2+, and Zn2+ removal efficiencies of 54.98%, 30.63%, 55.04%, and 75.35% were achieved in the effluent within optimum HRT of 2 hours under the continuous mode. The incomplete removal of Cu2+, Ni2+ and Zn2+ ions in the effluent was due to the fact that the Cr6+ was almost completely consumed at the end of MFC reaction. After HRT of 12 hours, at the different sampling locations, Cr6+ and Cu2+ removal efficiencies in the cathodic chamber of MFC were 89.95% and 34.69%, respectively. 94.58%, 33.95%, 56.57%, and 75.76% were achieved for Cr6+, Cu2+, Ni2+ and Zn2+ in the cathodic chamber of MEC. It can be concluded that those metal ions can be removed completely by repeatedly passing high concentration of Cr6+ through the cathode chamber of MFC of the MFC-MEC-coupled system.

Effect of Ammonium and Nitrate on Current Generation Using Dual-Cathode Microbial Fuel Cells

  • Jang, Jae-Kyung;Choi, Jung-Eun;Ryou, Young-Sun;Lee, Sung-Hyoun;Lee, Eun-Young
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권2호
    • /
    • pp.270-273
    • /
    • 2012
  • These studies were conducted to determine the effects of various concentrations of ammonium and nitrate on current generation using dual-cathode microbial fuel cells (MFCs). Current generation was not affected by ammonium up to $51.8{\pm}0.0$ mg/l, whereas $103.5{\pm}0.0$ mg/l ammonium chloride reduced the current slightly. On the other hand, when $60.0{\pm}0.0$ and $123.3{\pm}0.1$ mg/l nitrate were supplied, the current was decreased from $10.23{\pm}0.07$ mA to $3.20{\pm}0.24$ and $0.20{\pm}0.01$ mA, respectively. Nitrate did not seem to serve as a fuel for current generation in these studies. At this time, COD and nitrate removal were increased except at $123{\pm}0.1$ mg ${NO_3}^-/l$. These results show that proper management of ammonium and nitrate is very important for increasing the current in a microbial fuel cell.

미생물연료전지(MFC)에서 전류차단법(current interrupt technique)을 이용한 활성화전압손실(activation loss)과 저항전압손실(Ohmic loss)의 측정 (Measurement of Activation and Ohmic Losses using a Current Interruption Technique in a Microbial Fuel Cell)

  • 박경원;오상은
    • 대한환경공학회지
    • /
    • 제32권4호
    • /
    • pp.357-362
    • /
    • 2010
  • 미생물연료전지는 미생물이 유기물을 분해하면서 전기를 발생시킨다. 미생물연료전지는 여러 분야로 응용이 가능하며 현재 생산되는 전력이 낮기 때문에 상용화가 되기 위해서는 미생물연료전지(MFC)의 전력을 증진시키는 방안 연구가 필요하다. 미생물연료전지(MFC)의 전력을 증진시키기 위해서는 산화, 환원전극에서의 활성화전압손실(Activation losses)과 저항전압손실(Ohmic losses)을 줄여야 하며 활성화전압손실과 저항전압손실의 정확한 측정과 이를 줄이기 위한 인자를 찾는 것이 중요하다. 본 연구에서는 H형태의 미생물연료전지(Microbial Fuel Cell, MFC)에서 전류차단법(Current interruption)을 이용하여 산화전극 및 환원전극에서의 활성화 전압손실과 저항전압손실을 측정하였다. H형태의 미생물연료전지에서 백금이 코팅된 전극(0.5 $mg/cm^2$; 10% Pt)을 환원전극으로 이용하였음에도 환원전극 전압손실이 산화전극 전압손실보다 4배 가량 큼을 알 수 있었다. 전류차단법(Current interruption)에 의하여 구한 저항전압손실 값(1146 ${\Omega}$) 과 impedance에 의하여 구한 내부저항(1167 ${\Omega}$)은 거의 일치하였다. 또한 산화, 환원전극 활성화 전압손실의 합은 전지(cell)의 활성화 전압손실과 일치하였다.

Performances of Metallic (sole, composite) and Non-Metallic Anodes to Harness Power in Sediment Microbial Fuel Cells

  • Haque, Niamul;Cho, Daechul;Kwon, Sunghyun
    • Environmental Engineering Research
    • /
    • 제19권4호
    • /
    • pp.363-367
    • /
    • 2014
  • One chambered sediment microbial fuel cell (SMFC) was equipped with Fe, brass (Cu/Zn), Fe/Zn, Cu, Cu/carbon cloth and graphite felt anode. Graphite felt was used as common cathode. The SMFC was membrane-less and mediator-less as well. Order of anodic performance on the basis of power density was Fe/Zn ($6.90Wm^{-2}$) > Fe ($6.03Wm^{-2}$) > Cu/carbon cloth ($2.13Wm^{-2}$) > Cu ($1.13Wm^{-2}$) > brass ($Cu/Zn=0.24Wm^{-2}$) > graphite felt ($0.10Wm^{-2}$). Fe/Zn composite anode have twisted 6.73% more power than Fe alone, Cu/carbon cloth boosted power production by 65%, and brass (Cu/Zn) produced 65% less power than Cu alone. Graphite felt have shown the lowest electricity generation because of its poor galvanic potential. The estuarine sediment served as supplier of oxidants or electron producing microbial flora, which evoked electrons via a complicated direct microbial electron transfer mechanism or making biofilm, respectively. Oxidation reduction was kept to be stationary over time except at the very initial period (mostly for sediment positioning) at anodes. Based on these findings, cost effective and efficient anodic material can be suggested for better SMFC configurations and stimulate towards practical value and application.

미생물연료전지에서 전극구조가 기질분해에 미치는 영향 연구 (Effect of Electrode Configuration on the Substrate Degradation in Microbial Fuel Cells)

  • 신유진;이명은;박치훈;안용태
    • 대한환경공학회지
    • /
    • 제39권8호
    • /
    • pp.489-493
    • /
    • 2017
  • 미생물연료전지는 하폐수에 존재하는 다양한 유기성물질을 전기에너지로 변환시킬 수 있는 생물전기화학적공정이다. 본 연구에서는 전산모사를 통하여 산화전극의 크기, 전극간 거리, 전체 산화전극면적이 기질분해에 미치는 영향을 알아보고자 하였다. 생활하수를 처리하는 다중산화전극 및 SPA (Spaced electrode assembly)형 연속식 미생물연료전지공정을 모사하였으며, 전산모사결과에 따르면 단일전극의 크기에 의한 영향보다는 전극간 거리가 짧을수록 기질분해속도가 빠른 것으로 나타났다. 특히 전체 산화전극의 면적이 큰 경우가 기질분해가 가장 빠른 것으로 나타났다. 본 연구를 통하여 미생물연료전지공정의 설계에 있어서 율속단계로 알려진 환원전극의 크기 외에도 산화전극의 크기 및 전극간 거리 또한 기질분해 속도에 영향을 미칠 수 있는 중요한 인자임을 알 수 있었다.